Honeywell
MultiRAE Lite
This multi-gas monitor provides versatile, customizable detection and monitoring of up to six gases, available in both pumped and diffused air models. With more than 25 sensors to choose from — the broadest selection in its class — it can test for VOCs, combustibles, and a range of toxic threats, as well as monitor sufficient oxygen levels, making it an excellent choice for personal protection and leak detection in a range of industries and applications. The wireless connection sends threat and alarm data in real time to a central command, providing superior awareness for fast incident response. And its replaceable sensors, alarm, and battery, large screen, and automated bump testing and calibration make it easy to use and maintain.

MultiRAE Lite
Wireless Portable Multi-Gas Monitor
The MultiRAE Lite is the optimal one-to-six-gas monitor for personal protection and leak detection applications. The MultiRAE Lite is available in pumped and diffusion versions and features the broadest selection of sensor options in its class. The MultiRAE Lite can be configured to exactly meet the detection needs and compliance requirements of various countries, industries, and applications.
The MultiRAE Lite’s optional wireless capability improves safety by providing commanders and safety officers real-time access to instrument readings and alarm status from any location for better situational awareness and faster incident response.
-
Wireless access to real-time instrument readings and alarm status from any location
-
Unmistakable five-way local and remote wireless notification of alarm conditions including Man Down Alarm
-
Over 25 interchangeable sensor options, including PID4 for VOCs, NDIR5 and catalytic for combustibles, and NDIR for CO2
-
Device Management with Honeywell SafetySuite
-
Intelligent sensors store calibration data, so they can be swapped in the field
-
Large graphical display with easy-to-use, icon-driven user interface
-
Continuous datalogging (6 months for 5 sensors, 24x7)
Applications
Personal protection and multi-gas leak detection in industries such as:
-
Chemical
-
Food and beverage
-
Oil and gas (downstream)
-
Pharmaceutical
-
Telecommunications
-
Wastewater treatment
Fire overhaul
Instrument Specifications
- Size
- Pumped model: 7.6” H x 3.8” W x 2.6” D (193 x 96.5 x 66mm)
- Diffusion model: 6.9” x 3.8” x 2.2” (175 x 96.5 x 56 mm)
- Weight
- Pumped model: 31 oz (880 g)
- Diffusion model: 26.8 oz (760g)
- Sensors
- Over 25 intelligent interchangeable field-replaceable sensors including PID for VOCs, electrochemical sensors for toxic gases and oxygen, combustible LEL and NDIR sensors, and CO2 NDIR sensor
- Battery Options
- Rechargeable Li-ion ∼12-hr. (pumped) / 18-hr. (diffusion) runtime, < 6-hr. recharge time
- Extended duration Li-ion ∼18-hr. (pumped) / 28-hr. (diffusion) runtime, < 9-hr. recharge time
- Alkaline adapter with 4 x AA batteries ∼6-hr. (pumped) / 8-hr. (diffusion) runtime
- Display Readout
- Real-time reading of gas concentrations; PID measurement gas and correction factor; Man Down Alarm on/off; visual compliance indicator; battery status; datalogging on/off; wireless on/off and reception quality.
- STEL, TWA, peak, and minimum values
- Keypad Buttons
- 3 operation and programming keys Mode, Y/+, and N/-. Multiple User Options can be selected
- Sampling
- Built-in pump or diffusion
- Calibration
- Automatic with AutoRAE 2 Test and Calibration System or manual
- Alarms
- Wireless remote alarm notification; audible (95 dB @ 30 cm), vibration, visible (flashing bright red LEDs), and on-screen indication of alarm conditions
- Man Down Alarm with pre-alarm and real-time remote wireless notification
- Datalogging
- Continuous datalogging (6 months for 5 sensors at 1-minute intervals, 24/7)
- User-configurable datalogging intervals (from 1 to 3,600 seconds)
- Communications & Data Download
- Data download and instrument set-up and upgrades on PC via desktop charging and PC comm. cradle, travel charger, or AutoRAE 2 Automatic Test and Calibration System
- Wireless data and alarm status transmission via built-in RF modem (optional)
- Wireless Network
- ProRAE Guardian Real-Time Wireless Safety System or EchoView Host-based Closed-Loop System
Instrument Specifications (Cont'd)
- Wireless Range (Typical)
- MultiRAE Lite to RAELink3 [Z1] Mesh modem ∼330 feet (100 meters)
- MultiRAE Lite to EchoView Host, RAEMesh Reader or RAEPoint ∼660 feet (200 meters)
- MultiRAE Lite to Wi-Fi Access Point - 330 feet (100 meters)
- Operating Temperature
- -4° to 122°F (-20° to 50°C)
- Humidity
- 0% to 95% relative humidity (non-condensing)
- Dust and Water Resistance
- IP-65 (pumped); IP-67 (diffusion) ingress protection rating
- Safety Certifications
- CSA
- Class I, Division 1, Groups A, B, C and D, T4
- Class II, Division 1, Groups E, F, G T85°C
- ATEX
- 0575 II 1G Ex ia IIC T4 Ga
- 2G Ex ia d IIC T4 Gb with IR Sensor installed
- I M1 Ex ia I Ma
- IECEx
- Ex ia IIC T4 Ga
- Ex ia d IIC T4 Gb with IR Sensor installed
- I M1 Ex ia I Ma
- IECEx/ANZEx
- Ex ia IIC T4 Ga
- Ex ia d IIC T4 Gb with IR Sensor installed
- Ex ia I Ma
- EMC/RFI
- EMC directive: 2004/108/EC
- Performance Tests
- LEL CSA C22.2 No. 152; ISA-12.13.01
- Languages
- Arabic, Chinese, Czech, Danish, Dutch, English, French, German, Indonesian, Italian, Japanese, Korean, Norwegian, Polish, Portuguese, Russian, Spanish, Swedish, and Turkish
- Warranty
- Four years on Liq O2 sensors
- Three years on CO and H2S sensors
- Two years on non-consumable components and catalytic LEL sensors
- One year on all other sensors, pump, battery, and other consumable parts
- Wireless Frequency
- ISM license free band. IEEE 802.15.4 Sub 1GHz - Wi-Fi 802.11 b/g
- Wireless Approvals
- FCC Part 1.5, CE R&TTE, Others
- Radio Module
- Supports RM900A
Sensor Specifications
- VOC 10.6 EV
- Range: 0 to 1,000 ppm
- Resolution: 1 ppm
- Catalytic LEL
- Range: 0 to 100% LEL
- Resolution: 1% LEL
- NDIR (0-100% LEL Methane)
- Range: 0 to 100% LEL
- Resolution: 1% LEL
- NDIR (0-100% VOL. Methane)
- Range: 0 to 100% Vol
- Resolution: 0.1% Vol
- Carbon Dioxide (CO2) NDIR
- Range: 0 to 50,000 ppm
- Resolution: 100 ppm
- Ammonia (NH3)
- Range: 0 to 100 ppm
- Resolution: 1 ppm
- Carbon Monoxide (CO)
- Range: 0 to 500ppm
- Resolution: 1 ppm
- Carbon Monoxide (CO), Ext. Range
- Range: 0 to 2,000 ppm
- Resolution: 10 ppm
- Carbon Monoxide (CO), H2-Comp.
- Range: 0 to 2,000 ppm
- Resolution: 10 ppm
- Carbon Monoxide / Hydrogen Sulfide Combo
- Carbon Monoxide
- Range: 0 to 500ppm
- Resolution: 1 ppm
- Hydrogen Sulfide
- Range: 0 to 200ppm
- Resolution: 0.1 ppm
- Chlorine (CL2)
- Range: 0 to 50 ppm
- Resolution: 0.1 ppm
- Chlorine Dioxide (CLO2)
- Range: 0 to 1 ppm
- Resolution: 0.03 ppm
- Ethylene Oxide (ETO-A)
- Range: 0 to 100 ppm
- Resolution: 0.5 ppm
- Ethylene Oxide (ETO-B)
- Range: 0 to 10 ppm
- Resolution: 0.1 ppm
- Ethylene Oxide (ETO-C), Ext. Range
- Range: 0 to 500 ppm
- Resolution: 10ppm
- Formaldehyde (HCHO)
- Range: 0 to 10ppm
- Resolution: 0.05 ppm
- Hydrogen (H2)
- Range: 0 to 1,000 ppm
- Resolution: 10 ppm
- Hydrogen Cyanide (HCN)
- Range: 0 to 50 ppm
- Resolution: 0.5 ppm
- Hydrogen Sulfide (H2S)
- Range: 0 to 100 ppm
- Resolution: 0.1 ppm
- Hydrogen Sulfide (H2S), Ext. Range
- Range: 0 to 1,000 ppm
- Resolution: 1 ppm
- Methyl Mercaptan (CH3-SH)
- Range: 0 to 10 ppm
- Resolution: 0.1 ppm
- Nitric Oxide (NO)
- Range: 0 to 250 ppm
- Resolution: 0.5 ppm
- Nitrogen Dioxide (NO2)
- Range: 0 to 20 ppm
- Resolution: 0.1 ppm
- Oxygen (O2)
- Range: 0 to 30% Vol
- Resolution: 0.1% Vol
- Oxygen (LIQ O2)
- Range: 0 to 30% Vol
- Resolution: 0.1% Vol
- Phosphine (PH3)
- Range: 0 to 20 ppm
- Resolution: 0.1 ppm
- Phosphine H (PH3 H)
- Range: 0 to 20 ppm
- Resolution: 0.1 ppm
- Sulfur Dioxide (SO2)
- Range: 0 to 20 ppm
- Resolution: 0.1 ppm