    FLIR Griffin G510

    Person-Portable GC/MS Chemical Identifier

    A gas chromatograph mass spectrometer you carry to the sample. The G510 lets responders analyze liquids, solids and vapors and perform rapid field confirmation of chemical hazards, with a heated sample probe for Survey Mode and a split/splitless injector for liquids, all in one self-contained, IP65-rated enclosure.

    16.3 kg36 lbs with batteries, carrier gas & vacuum
    IP65Dust-tight, spray-resistant
    15 - 515m/z mass range
    9"Touchscreen, usable in full PPE
    FLIR Griffin G510 portable GC/MS with its heated sample probe on a coiled cable, screen showing Survey Mode
    VaporHeated probe LiquidSyringe injector SolidPSI-Probe, optional
    Field confirmation
    Presumptive says maybe.
    GC/MS says what.

    Teledyne FLIR built the G510 to complement the presumptive techniques responders already use during emergency operations. It analyzes all phases of matter and performs rapid field confirmation of chemical hazards, on scene.

    In the hot zone the integrated heated sample probe identifies vapor-phase threats within seconds in Survey Mode. When the question needs a full answer, the same instrument separates the sample on its GC column and identifies it by mass spectrum.

    Vapor
    Liquid
    Solid
    How GC/MS works in the field

    Sample. Separate. Identify.

    Every G510 result follows the same three stages a laboratory GC/MS uses: get the sample in, pull the mixture apart over time on a gas chromatography column, then identify each component by its mass spectrum against on-board libraries.

    01

    Sample

    Bring the sample in as a vapor, a liquid or a solid. The heated sample probe and the split/splitless injector are both included standard.

    • VaporHeated Sample Probe: survey via Membrane Introduction Mass Spectrometry (MIMS) Inlet; confirmation via Internal Dual-Bed Preconcentrator
    • LiquidSplit/splitless injector: direct liquid sampling (organic solution) via syringe
    • SolidPSI-Probe™ thermal separation via TAG™ (optional accessories)
    02

    Separate

    The gas chromatograph splits a mixture into its components so each one reaches the mass spectrometer on its own. FLIR describes the low thermal mass column as giving "unsurpassed resolution in challenging environments."

    • LTM-GC columnDB-5MS (15 m x 0.18 mm x 0.25 µm); others available.
    • Temperature rangeProgrammable 40 to 300°C; ramping of 100°C/min
    • Carrier gasOn-board helium; external helium connector, automatic switching (Hydrogen capable).
    03

    Identify

    Each component is ionized and its mass spectrum is matched against named on-board libraries, then reported with visual and audible alarms that need limited data interpretation.

    • Mass analyserLinear quadrupole mass filter.
    • Mass range / resolution15 - 515 m/z; 0.7 amu@FWHM.
    • IonisationElectron Impact Ionisation; non-radioactive ionisation source.
    • LibrariesNIST/EPA/NIH mass spectral library
    Griffin G510 details screen with a mass spectrum at top, a library hit list and a total ion chromatogram of an n-alkane mixture below
    Example details screen
    Reading a result

    Both stages on one screen

    This details view comes from a single syringe injection in FLIR's fire-investigation application note, which identified C9 through C28 hydrocarbons.

    • 1Total ion chromatogram. Each peak is a component the GC column separated out, plotted against time.
    • 2Mass spectrum. The fragment pattern of the selected peak, the fingerprint the libraries match against.
    • 3Hit list. Library names for the selected peaks, here hexacosane and its neighbors.
    Sampling options

    Three phases, three ways in

    Teledyne FLIR calls it "unmatched field versatility": sampling options for vapor, liquid and solid materials, enabling rapid analysis across a wide range of operational scenarios.

    VaporGloved hand holding the Griffin G510 heated vapor probe over chemical containers

    Heated sample probe

    A handheld probe on the instrument's cable, with its own alarm. It runs the rapid-response survey mode and feeds vapor confirmation.

    • SurveyVapour survey mode via Membrane Introduction Mass Spectrometry (MIMS) Inlet.
    • ConfirmationVapour confirmation via Internal Dual-Bed Preconcentrator.
    • AlertsAudible and Visual (Touchscreen and Handheld Probe).
    LiquidGloved hand injecting a sample by syringe into the Griffin G510 injector port

    Split/splitless injector

    For environmental, forensic and hazardous material sampling by syringe injection of organic liquids.

    • StandardDirect liquid sampling (organic solution) via syringe.
    • ExtractionLiquid extraction via SPME fiber or PSI-Probe w/ Gerstel Twister™ Optional
    • CollectionLinks with SPME and headspace sample collection tools.
    Solid

    Direct analysis of solids

    Options include a Prepless Sample Introduction (PSI) Probe, a Sample Prep Kit (SPK) and Touch-And-Go (TAG™) capability for direct analysis of solid samples.

    • SolidSolid PSI-Probe™ thermal separation via TAG™ Optional
    • Sample phaseSolid, liquid, and vapour.

    PSI-Probe, TAG and SPME extraction are optional accessories. Tell us how you plan to sample when you request a quote.

    Two operating speeds

    Seconds to screen, minutes to confirm

    The G510's time claims depend on the mode. Survey Mode is near real-time vapor identification from the heated probe; a full GC/MS run takes minutes and separates the whole sample.

    Operator in camouflage holding the Griffin G510 probe cable while carrying the instrument past shelves of chemical containers
    Mode 01

    Survey Mode

    Sweep the heated probe through the area. Vapor is drawn to the Membrane Introduction Mass Spectrometry (MIMS) inlet, so hot zone operators can identify vapor-phase chemical threats within seconds.

    Seconds
    Identification, near real-time
    015 min
    Inlet
    Membrane Introduction Mass Spectrometry (MIMS) Inlet
    Battery
    4 hrs in Survey Mode; hot swappable
    Hot zone
    Sealed for Survey Mode operation in the hot zone
    Griffin G510 confirm detection screen listing pyridine as an identified target
    Mode 02

    Confirmation

    Vapor is concentrated on the internal dual-bed preconcentrator, or a liquid is injected, then separated on the GC column and identified. In a FLIR application note, pyridine vapor was detected in less than two minutes and confirmed with a NIST match (screen above).

    4 - 15 mins
    Full identification, most chemicals
    015 min
    Inlets
    Internal Dual-Bed Preconcentrator (vapor); split/splitless injector (liquid)
    Battery
    2 hrs in Confirmation Mode; hot swappable
    Example
    Fentanyl and heroin in one run, under ten minutes (FLIR application note)
    Start-up15 minutes to full operation from cold.
    Power2 x #2590 @ 15V Li Ion batteries (included), hot swappable; 100-240V 50-60Hz mains.
    CalibrantOn-board FC-43 (Perfluorotributylamine)
    Libraries & alarms

    Named libraries, simple answers

    Identification is only as good as the reference data behind it. The G510 matches against established mass spectral libraries and turns the result into a guided, alarm-driven screen an operator in PPE can act on.

    NIST/EPA/NIH

    Mass Spectral Library

    Griffin Match Factor (GMF)

    FLIR's fire-investigation note describes GMF as combining NIST mass spectrum library matches with retention indexing to provide additional confidence.

    Library match+Retention index=GMF
    • 01

      Confirmatory identification of unknowns and mixtures

      On-board mass spectral libraries provide confirmatory identification and analysis of trace compounds, unknown chemicals and mixtures.

    • 02

      Alarms with limited data interpretation

      Visual and audible alarm confirmation on the touchscreen and the handheld probe.

    • 03

      Guided touchscreen, usable in PPE

      A 9" multitouch color display (1280 x 720 WVGA; 1300 nits) with a navigation assistant and Method Selector tool, operable while wearing full personal protective equipment downrange.

    • 04

      Methods for drugs of abuse included

      FLIR's application note states that standard analytical methods for drugs of abuse, including fentanyl and heroin, are included with the G510 and linked to the full NIST Mass Spectral Library.

    • 05

      Remote monitoring and data storage

      On-board WiFi and GPS, with remote monitoring and control over a WiFi hotspot. Results are stored on an internal 256GB SSD.

    Field notes

    Two scenes, documented by FLIR

    Teledyne FLIR application notes show the G510 at a suspected drug lab and at a fire scene.

    Interior of a cluttered clandestine drug laboratory with glassware and chemical containers on benches
    Application note

    Detection of fentanyl using portable GC/MS

    Portable GC/MS equipment can help hazmat response teams quickly identify white powders, like fentanyl, on scene. The note walks through two results from the G510:

    • <10 minFentanyl and diacetylmorphine (the most common chemical name for heroin) detected in a single GC/MS sample run.
    • <2 minPyridine, a common solvent used in producing fentanyl and likely in a clan-lab scenario, detected and confirmed with a NIST match.
    Griffin G510 injection detection screen listing diacetylmorphine and fentanyl as identified targets
    Burned-out room after a structure fire, walls and furniture charred
    Application note

    The art of GC-MS for fire investigation

    A portable GC-MS like the G510 can be used to confirm the presence of a suspected accelerant immediately on scene. Besides its standard injector, the G510 carries an air sampling probe for extra utility at the fire scene.

    • C9-C28Hydrocarbons identified from a single syringe injection (the result shown in "Reading a result" above).
    • GMFGriffin Match Factor combines NIST library matches with retention indexing for additional confidence.
    Person carrying a Griffin G510 by its top handle across pavement

    FLIR's conclusion: the results "indicate the FLIR Griffin G510 is capable of field analysis of ignitable liquid residues at a fire scene."

    Built for the field

    One box, nothing to plug in

    Teledyne FLIR describes the G510 as a fully self-contained, mission-ready system for reliable operation from the field to the lab: carrier gas, batteries and vacuum pumps are inside the 36-pound case.

    Responder in a lime-green chemical suit carrying the Griffin G510 and sampling beside steel drums with the heated probe
    36 lbs, one hand on the handle, one on the probe
    Gloved hand loading a helium carrier-gas cartridge into a bay on a Griffin GC/MS
    Integrated carrier gas
    Responder in a lime-green chemical protective suit sampling beside containers with the Griffin G510
    Operated in full PPE
    • 01

      IP65-rated enclosure

      Dust-tight and spray-resistant, which FLIR notes adds flexibility to decontamination procedures.

    • 02

      Built-in active pumping

      Self-contained miniature turbomolecular and diaphragm pumps, so no external service module is needed.

    • 03

      Carrier gas, batteries and training videos on board

      On-board helium with an external connector and automatic switching; two hot-swappable Li-ion batteries; training reference videos built in.

    • 04

      Simple field maintenance

      Maintenance activities are designed to be done in the field for increased uptime. Teledyne FLIR states that extensive training, service and reachback options are available.

    • 05

      Short training path

      2 hours basic operation; 8 hours expert user. An optional vehicle mount kit is available for shock and vibration protection during off-road or harsh transport.

    Applications named by Teledyne FLIR

    • Drug testing and discovery
    • Food safety / contamination detection
    • Forensic analysis
    • Environmental analysis
    • Toxic industrial chemical detection
    • Pharmaceutical manufacturing
    • Research laboratories
    • Oil and gas
    Choosing a Griffin

    G510 vs G510x

    Two person-portable Griffin GC/MS instruments for two jobs. The G510 is the general chemical identifier with the heated probe and Survey Mode. The G510x, a variant built on the G510, is specifically optimized for the detection of narcotics and explosives.

    Spec
    Griffin G510This page
    Griffin G510xNarcotics & explosives
    Focus
    Versatile, person-portable chemical identifier for all phases of matter
    Specifically optimized for the detection of Narcotics and Explosives
    Heated probe / Survey Mode
    Heated Sample Probe (included standard); identification within seconds in Survey Mode
    —
    Sample introduction
    Split/splitless injector (included standard): direct liquid sampling via syringe
    Sample Injection Port (included standard): direct liquid sampling via Merlin Micro shot; Sample Prep Kit (SPK)
    Identification time
    Full identification in 4 - 15 mins for most chemicals
    Confirmatory Identification of major and minor chemical constituents in street drugs in under 5 min. (street-drug constituents)
    Mass range
    15 - 515 m/z; 0.7 amu@FWHM
    40-515 m/z; 0.7 amu @ FWHM
    LTM-GC column
    DB-5MS (15 m x 0.18 mm x 0.25 µm); others available
    RTX-TNT (5 m x .18 mm x .2 um)
    Libraries
    NIST/EPA/NIH mass spectral library included
    SWGDRUG and GriffinLib included; NIST/EPA/NIH optional
    Detection limit
    PPM (parts per million) - PPT (parts per trillion)
    PPM (parts per million) via Syringe, and PPB (part per billion) via SPME
    Battery life
    4 hrs in Survey Mode, 2 hrs in Confirmation Mode; hot swappable
    4 hrs hot swappable
    Ingress rating
    IP65-rated, dust-tight and spray-resistant
    —
    Shared
    16.3 kg (36 lbs) with batteries, carrier gas and vacuum system · 9" multitouch display · linear quadrupole · 7 decades dynamic range · 15 minutes to full operation from cold
    Same on both models
    View the Griffin G510x

    Not sure which fits your mission? Tell us what you need to identify and how you sample, and we will help you compare.

    Specifications

    Griffin G510 specifications

    Physical
    TechnologyGas Chromatography / Mass Spectrometry (GC/MS).
    Dimensions (L x W x H)33.7 x 33.7 x 40 cm (13.25 x 13.25 x 15.75") – include batteries, carrier gas, and vacuum system.
    Weight16.3 kg (36 lbs) – include batteries, carrier gas, and vacuum system.
    DecontaminationSealed for Survey Mode operation in hot zone; IP65-rated enclosure is dust-tight and spray-resistant.
    Environment
    Operating temp / humidity32 to 104 °F (0 to 40 °C); <95% relative humidity
    Storage temperature-25 to 55°C (-13 to 131°F).
    Power
    Power supply100-240V 50-60Hz (220 W max); 19V (DC); 2 x #2590 @ 15V Li Ion batteries (included)
    Battery life4 hrs in Survey Mode, 2 hrs in Confirmation Mode; hot swappable.
    Start up time15 minutes to full operation from cold.
    Sample introduction
    Sample phaseSolid, liquid, and vapour.
    Heated Sample Probe (included standard)
    • Vapour survey mode via Membrane Introduction Mass Spectrometry (MIMS) Inlet.
    • Vapour confirmation via Internal Dual-Bed Preconcentrator.
    Split/splitless injector (included standard)
    • Direct liquid sampling (organic solution) via syringe.
    • Liquid extraction via SPME fiber or PSI-Probe w/ Gerstel Twister™*
    • Solid PSI-Probe™ thermal separation via TAG™*
    *Optional accessories.
    Performance
    Sampling and analysisFull identification in 4 - 15 mins for most chemicals; identification within seconds (near real-time) when operating in Survey Mode.
    Detection limitPPM (parts per million) - PPT (parts per trillion).
    ThreatsDetects and identifies explosives, narcotics, CWAs, TICs, environmental pollutants, and other chemicals
    Gas chromatograph
    LTM-GC columnDB-5MS (15 m x 0.18 mm x 0.25 µm); others available.
    Temperature rangeProgrammable 40 to 300°C; ramping of 100°C/min
    Carrier gasOn-board helium; external helium connector, automatic switching (Hydrogen capable).
    Mass spectrometer
    Mass analyser typeLinear quadrupole mass filter.
    Mass range / resolution15 - 515 m/z; 0.7 amu@FWHM.
    Ionisation type / sourceElectron Impact Ionisation; non-radioactive ionisation source.
    DetectorElectron Multiplier.
    Vacuum systemSelf-contained miniature turbomolecular and diaphragm pumps.
    Dynamic range7 decades.
    CalibrantOn-board FC-43 (Perfluorotributylamine)
    Reference data
    Standard reference databaseNIST/EPA/NIH Mass Spectral Library
    Interface
    Display9" Multitouch Color Display (1280 x 720 WVGA;1300 nits brightness).
    AlertsAudible and Visual (Touchscreen and Handheld Probe).
    SoftwareGSS Touch; multiple user levels.
    Connectivity & data
    Communication2 x USB 2.0, Bluetooth 4.0, WiFi 802.11n, Ethernet via USB, integrated GPS.
    Data storageInternal 256GB SSD.
    Training
    Training requirements2 hours basic operation; 8 hours expert user.
    FAQ

    Common questions

    How fast does the Griffin G510 identify a chemical?
    It depends on the mode. In Survey Mode the heated sample probe gives identification within seconds (near real-time) for vapors. A full GC/MS identification takes 4 - 15 mins for most chemicals. Allow 15 minutes to full operation from a cold start.
    What kinds of samples can it analyze?
    Solid, liquid, and vapour. Vapor is taken with the heated sample probe (included standard); organic liquids go in by syringe through the split/splitless injector (included standard). Solids are handled by PSI-Probe thermal separation via TAG, and SPME extraction is also supported; those are optional accessories.
    Which libraries does it use?
    The G510 includes the NIST/EPA/NIH Mass Spectral Library.
    What can it detect?
    It detects and identifies explosives, narcotics, toxic industrial chemicals (TICs), environmental pollutants and other chemicals. FLIR application notes show it identifying fentanyl and heroin in a single run and ignitable liquid residues at a fire scene.
    Is it really portable and self-contained?
    Yes. It weighs 16.3 kg (36 lbs) including batteries, carrier gas and vacuum system, measures 33.7 x 33.7 x 40 cm, and has an IP65-rated enclosure. Built-in active pumping means no external service module is needed.
    How long do the batteries last?
    4 hrs in Survey Mode and 2 hrs in Confirmation Mode, and the two included Li-ion batteries are hot swappable. It also runs from 100-240V 50-60Hz mains power.
    How much training does an operator need?
    Training takes 2 hours for basic operation and 8 hours for an expert user. The touchscreen has a navigation assistant and Method Selector tool, and alarms are designed to need limited data interpretation.
    Should I choose the G510 or the G510x?
    The G510 is the general-purpose identifier with the heated sample probe, Survey Mode and an IP65 enclosure. The Griffin G510x is specifically optimized for the detection of narcotics and explosives, with a sample prep kit and a different column and mass range. See the side-by-side comparison.
    Is the G510 export controlled?
    Teledyne FLIR notes that the product may be subject to the International Traffic in Arms Regulations (ITAR) or the Export Administration Regulations (EAR) depending on the final specifications, and that jurisdiction and classification are provided on request. Include your end-use details when you request a quote.
    Who services it?
    Contact the FarrWest Repair Depot. When a repair or calibration falls outside our in-house scope, we coordinate directly with the third-party manufacturer and manage the logistics end to end.
    Next step

    Confirm chemicals on scene

    Tell us what you need to identify, how you plan to sample and where the instrument will deploy. We will follow up with pricing and configuration options for the Griffin G510, or help you decide whether the G510x fits better.