Honeywell
ToxiRAE Pro
The ToxiRAE Pro family is the industry’s first and largest family of wireless, personal single-gas monitors that can reliably and accurately monitor a full range of common toxic industrial chemicals (TICs), volatile organic compounds (VOCs), combustible gases, carbon dioxide (CO2), and Oxygen (O2).

ToxiRAE Pro Family
A full range of wireless personal single-gas monitors
The ToxiRAE Pro is the world’s first wireless personal monitor for toxic gases and oxygen. The ToxiRAE Pro can detect a broad range of gases—from carbon monoxide, hydrogen sulfide, and oxygen to ammonia, chlorine, and formaldehyde. The ToxiRAE Pro provides safety professionals wireless remote access to real-time instrument readings and alarm status for better visibility and faster incident response. The ToxiRAE Pro’s intelligent interchangeable sensors store calibration data, which allows users to monitor for one gas one day and another gas the next, by simply swapping the sensors in the ToxiRAE Pro.
The ToxiRAE Pro provides unmistakable five-way local and remote alarms if a threat is detected or a man is down. The LCD display provides visual feedback that includes sensor type, readings, time, battery condition, and other functions. It offers the flexibility of easily swappable sensors to monitor for different gases in different situations. Applications include: agriculture, chemical fire service/HazMat, food & beverage, oil and gas, pharmaceutical, pulp and paper, steel manufacturing, water and wastewater industries.
Easy to maintain and calibrate
Anytime, anywhere access to real-time instrument reading and alarm status with ProRAE Guardian Software or EchoView Portable Controller
Five-way alarm notification — man down, and 4 instrument alarms
Rugged, IP-54 (PID) and IP-65 (EC, LEL, and CO2) protection rating
Compact and lightweight
3 months of continuous data logging
Field-replaceable battery, filter, sensor, and PID fan
Fully automated calibration with AutoRAE2
Wireless elevates safety to the next level
Wireless access to real-time instrument readings and alarm status from any location
Unmistakable five-way local and remote wireless notification of alarm conditions
Easy to use and maintain
Most electrochemical sensors are shared with MultiRAE family instruments
Device Management with Honeywell SafetySuite
Intelligent sensors store calibration data, so they can be swapped in the field
Rugged and Reliable
Reliable, rugged, and intrinsically safe
Largest display in its class
Instrument Specifications
- Size
- 4.6" H x 2.4" W x 1.2" D (118 x 60 x 30 mm)
- Weight
- 7.76 oz. (220 g)
- Sensors
- Over 20 intelligent interchangeable field-replaceable electrochemical sensors
- Battery
- Rechargeable Li-ion battery
- Operating time: > 30 hours (normal operation, non-wireless)
- Recharge time: < 4 hours through charging cradle
- Display
- Graphical LCD display with white LED backlighting (activated when monitor is in alarm or with a button press)
- Display Readout
- Real-time reading of gas concentrations in parts per million (ppm) or mg/m3; battery status; data logging on/off; wireless on/off and reception quality
- STEL, TWA, and peak values
- Keypad
- 2 buttons for operation and programming
- Sampling
- Diffusion
- Calibration
- Automatic with AutoRAE 2 Test and Calibration System or manual
- Alarm Modes
- Wireless remote alarm notification; audible (95 dB @ 30 cm), vibration, visible alarm (flashing bright red LEDs), and on-screen indication of alarm conditions.
- Man Down Alarm with pre-alarm and real-time remote wireless notification
- DataLogging
- Continuous datalogging with a three-month capacity (at one-minute intervals)
- User-configurable datalogging interval (from 1 to 3,600 seconds)
Instrument Specifications (Cont'd)
- Communication and Data Download
- Data download and instrument set-up on PC via charging and PC comm. cradle
- Data download via AutoRAE 2 Automatic Test and Calibration System
- Wireless data and status transmission1 via built-in RF modem (optional)
- Wireless Networking
- ProRAE Guardian Real-Time Wireless Safety System or Closed Loop Network with the EchoView Host
- Wireless Range (Typical)
- ToxiRAE Pro to Mesh Router, EchoView Host, or Mesh Reader
- approximately 660 feet (200 meters)
- ToxiRAE Pro to RAELink3 Mesh or RAELink3 Z1 Mesh modems
- approximately 330 feet (100 meters)
- Operating Temperature
- -4° to 131°F (-20° to 55°C)
- Humidity
- 0% to 95% relative humidity (non-condensing)
- Dust and Water Resistance
- IP-65 rating for dust and water ingress protection
- EMC/RFI
- EMC directive: 2004/108/EC
- Warranty
- Two years on O2 sensor
- Three years on H2S and CO sensors
- Two years on non-consumable components
- One year on all other sensors, battery, and other consumable parts
- Wireless Frequency
- ISM license-free band. IEEE 802.15.4 Sub 1GHz
- Wireless Approvals
- FCC Part 15, CE R&TTE, Others
- Radio Module
- Supports RM900
Sensor Specifications
Sensor | Range | Resolution |
---|---|---|
NH3 | 0-100 ppm | 1 ppm |
CO | 0-500 ppm | 1 ppm |
CO Ext. Range | 0-2000 ppm | 10 ppm |
CO H2-COMP | 0-2000 ppm | 10 ppm |
Cl2 | 0-50 ppm | 0.1 ppm |
ClO2 | 0-1 ppm | 0.03 ppm |
ETO-A | 0-100 ppm | 1 ppm |
ETO-B | 0-10 ppm | 0.1 ppm |
ETO-C Ext. Range | 0-500 ppm | 10 ppm |
HCHO | 0-10 ppm | 0.05 ppm |
H2 | 0-1000 ppm | 10 ppm |
HCN | 0-50 ppm | 0.5 ppm |
H2S | 0-100 ppm | 0.1 ppm |
H2S Ext. Range | 0-1000 ppm | 1 ppm |
CH3-SH | 0-10 ppm | 0.1 ppm |
NO | 0-250 ppm | 0.5 ppm |
NO2 | 0-20 ppm | 0.1 ppm |
O2 | 0-30% Vol | 0.1% |
PH3 | 0-20 ppm | 0.1 ppm |
SO2 | 0-20 ppm | 0.1 ppm |