1+ (210) 566 1857

  • 0
  • FLIR GRIFFIN G510

    PORTABLE GAS CHROMATOGRAPH MASS SPECTROMETER

    THE ULTIMATE CHEMICAL DETECTION TOOLBOX

    G510 page Top background

    FLIR GRIFFIN G510

    PORTABLE GAS CHROMATOGRAPH MASS SPECTROMETER

    THE ULTIMATE CHEMICAL DETECTION TOOLBOX

    G510 page Top background

    FLIR GRIFFIN G510

    PORTABLE GAS CHROMATOGRAPH MASS SPECTROMETER
    THE ULTIMATE CHEMICAL DETECTION TOOLBOX

    The FLIR Griffin G510 Gas Chromatograph Mass Spectrometer (GC/MS) is a versatile, person-portable chemical identifier. It complements presumptive techniques used during emergency missions, by enabling responders to analyze all phases of matter (liquid, solid, vapor) and by performing rapid field- confirmation of chemical hazards. The integrated heated sample probe enables hot zone operators to identify vapor-phase chemical threats within seconds when operated in Survey Mode. The integrated split/splitless injector allows for environmental, forensic, and hazardous material sampling via syringe injection of organic liquids. The 9” on-board touchscreen displays guided user prompts and can be operated while wearing full personal protective equipment (PPE) downrange. It is built with an IP65-rated enclosure for harsh environments and supports passive defense, interdiction, elimination, and consequence management missions. Long-lasting, on-board batteries ensure every mission is supported from beginning to end.

    • Laboratory level, gold-standard linear quadrupole mass analyzer
    • Simple on-board touchscreen with navigation assistant and Method Selector tool
    • Vapor sampling probe with rapid-response survey mode
    • Integrated split/splitless liquid injector accepts direct injection of organic liquids
    • Simple field maintenance activities for increased uptime

    For more information, available options, or to get a quote, please visit the Griffin G510 product page.

    Performance Redefined

    Confidently identify unknowns and take action with guided prompts and simple threat alarms.

    • Full NIST and SWGDRUG on-board libraries provide identification and analysis
    • of unknown chemicals Visual and audible alarm confirmation with limited data interpretation
    • On-board WiFi and GPS assist in maintaining result defensibility
    Someone using the G510

    Built for the field

    Completely self-contained and mission-ready from the field to the lab.

    • IP65-rated, dust-tight and spray-resistant
    • Built-in active pumping system eliminates need for an external service module
    • Integrated carrier gas, batteries, and training reference videos
    • Extensive training, service, and reachback options available
    Someone pressing a button on the G510

    Multiple Sampling Options

    Versatile in-field sampling options for vapor, liquid, and solid samples.

    • Available Prepless Sample Introduction Probe, Sample Prep Kit, and Touch-And-Go capability for direct analysis of solid samples
    • Effortlessly links with SPME and headspace sample collection tools
    • High-fidelity, low thermal mass (LTM) GC column for unsurpassed resolution in challenging environments
    People using the G510 to detect something in a bin

    PSI-PROBE ACCESSORY

    FLIR offers a revolutionary solution to the complicated challenge of eld sampling with the PSI-Probe accessory. The PSI-Probe is directly compatible with the robust Grif n G500-series GC/MS systems. The strengths of this analytical platform include the ability to transfer ultra-trace residues to the GC/MS system and perform eld characterizations and positive identi cation of chemicals within 15 minutes, all without the use of conventional sample preparation.

    The PSI-Probe is supplied in a ruggedized transport case, complete with a staging base, vial of TAGs, Twister Kit, Reverse Action Tweezers, spares kit, and an operator manual. The analytical platform contains pre-loaded methods and an updated mass spectral library presented in a unique, simpli ed user interface. This allows both advanced users and beginners to utilize the system to their expertise level.

    PSI-PROBE WITH TOUCH-AND-GO (TAG)

    Traditional sample preparation techniques are eliminated with the simple-to use Touch-and-Go (TAG) technology, which allows users to quickly collect solid or liquid samples. No solvents, dilutions, or wet chemistry are needed when using TAG. Simply touch or tap the TAG to your sample. After collecting the sample, the sampling end is broken into the microvial, which is then placed directly into the PSI-Probe. The PSI-Probe is inserted into the adapter on the GC/MS injector. The injector thermally extracts chemical components from the sample, while the GC/MSperforms subsequent chemical identification.

    Use Compatible with all Griffin GC/MS models; used for forensic and environmental analysis and incident response
    Size/Weight 3 x 6 in (7.6 x 15.2 cm) / 3 lbs (1.4 kg)
    Collection Phase Direct sampling of liquid, solid, and trace residues
    Sampling Standard test methods provided or additional methods can be developed using Griffin System Software
    TAG Pre-scored glass capillary that collects ultra-trace residues for direct analysis

    PSI-PROBE WITH GERSTEL-TWISTER

    The GERSTEL-Twister is a unique sampling tool. It is fast, eliminates the need for solvents, and is up to 1000 times more sensitive than SPME. It uses SBSE (stir bar sorptive extraction) to collect organic compounds directly from liquid samples, like drinking or waste water, bodily uids, or beverages. The Twister adsorbs and concentrates the organic contents onto its sorbent coating. Solid and vapor headspace samples can also be tested via Twister. Simply drop the Twister in a sample vial containing the liquid or solid and seal the vial. Then place the Twister vial on a stir plate. Remove, rinse, dry, and drop the SBSE into the PSI-Probe for thermal extraction and subsequent GC/MS analysis.

    Use Compatible with all Griffin GC/MS models; used for forensic and environmental analysis and incident response
    Size/Weight 3 x 6 in (7.6 x 15.2 cm) / 3 lbs (1.4 kg)
    Collection Phase Direct sampling of liquids and headspace sampling of solids
    Sampling Standard test methods provided or additional methods can be developed using Griffin System Software
    Twister Reusable Polydimethylsiloxane (PDMS)-coated stir bar (other options available)

    For more information, available options, or to get a quote, please visit the Griffin G510 product page.

    CONTACT US