No products in the cart.

  • Categories:

    BADD Botulinum Toxin Detection Test

    $0.00

    The BADD Botulinum Toxin Detection Test is a portable handheld assay for rapid screening of botulinum toxin threats in public safety applications.

    In stock

    or
    Add to Quote

    The BADD™ (Biowarfare Agent Detection Devices) test strips employ agent-specific antibodies to identify botulinum toxin threats. After sample preparation, five drops of liquid mix are added to the sample port. The sample interacts with reagents and moves along the test material via lateral-flow immunochromatography. Two solid bands indicate a positive result; one band indicates negative results. Provides results in 3-15 minutes. Handheld, portable design (3 x 1.5 x 0.5 inches, 8g). Sensitivity: Botulinum toxin A at 33 ng/mL. Operating temperature: 0-48°C. Shelf life: 2 years. Requires minimal training (<1 day). Manufactured by AdVnt Biotechnologies.

    Description

    BADD Botulinum Toxin Detection Test

    The BADD™ (Biowarfare Agent Detection Devices) test strips employ agent-specific antibodies to identify botulinum toxin threats. After sample preparation, five drops of liquid mix are added to the sample port. The sample interacts with reagents and moves along the test material via lateral-flow immunochromatography. Two solid bands indicate a positive result; one band indicates negative results. Provides results in 3-15 minutes. Handheld, portable design (3 x 1.5 x 0.5 inches, 8g). Sensitivity: Botulinum toxin A at 33 ng/mL. Operating temperature: 0-48°C. Shelf life: 2 years. Requires minimal training (<1 day). Manufactured by AdVnt Biotechnologies.

    Features

    • Agent-specific antibodies for threat identification

    • Lateral-flow immunochromatography detection

    • Visual band-based result interpretation

    • Handheld portable design

    • No power requirements

    • Multiple biological agent detection capability

    • Immediate startup time

    • Moderate resistance to interferents

    Specifications

    Manufacturer
    AdVnt Biotechnologies
    Product Name
    BADD™ (Biowarfare Agent Detection Devices)
    Detection Category
    Biological
    Detection Principle
    Immunological
    Detection Method
    Lateral Flow Hand Held Immunoassay
    Application
    Detection; Emergency Response; Screening
    Equipment Type
    Instrument
    Availability
    Commercially Available
    Technology Readiness Level (TRL)
    9
    Dimensions
    3 x 1.5 x .5 in (7.62 x 3.81 x 1.27 cm)
    Weight
    <1 lb.; 0.3 oz (8.0 g)
    Power Requirements
    None
    Noise Produced
    None
    Transportability
    Handheld
    Operating Conditions
    0 to 48°C (32 to 118°CF)
    Consumables
    None
    Calibration Schedule
    None
    Expected Operational Life
    1 year
    Shelf Life
    <5 years; 2 years
    Tested For Biological Agents
    B. Anthracis (Anthrax), Y. Pestis (Plague), Botulinum toxin A & B, Staphylococcal Enterotoxin B (SEB), Ricin, F. tularensis (Tularemia)
    Other Biological Targets
    Proteins (toxins), whole cells
    Adaptability
    Yes; user can add new targets to detector with support
    Sample Introduction
    Liquid
    Sensitivity/Detection Limits
    ng; µg; Vendor claim: Yersinia pestis 1.0 µg/mL, Staphylococcal Enterotoxin B (SEB)10 ng/mL, Bacillus anthracis 50 ng/mL, Botulinum toxin A 33 ng/mL, Ricin toxin 5 ng/mL.
    Start Up Time (From Cold Start To Sample Ready)
    Immediate
    Response Time (Sample Application To Output)
    <15 minutes; 3 to 15 minutes
    Alarm Capability
    Visual color change
    Training Required
    <1 day training
    Warranties
    1 year, limited
    U.S. EAR Compliant
    BADD products currently are designated as EAR99 and ship with unified code 3822-000000