    $0.00

    The Kappler Frontline 300 is a chemical and flash-fire protective ensemble built for petrochemical hazards.

    In stock

    or
    Add to Quote

    The Kappler Frontline 300 is a multi-use protective ensemble designed for personnel working around petrochemical line breaks and related hazards.

    It combines chemical resistance with flash-fire protection and radiant heat shielding, and its flexible design supports mobility for workers who need to move and perform tasks while suited up.

    • Chemical resistance
    • Flash-fire protection
    • Radiant heat shielding
    • Flexible, mobility-focused design

    Contact FarrWest for a quote.

    Description

    Frontline 300

    Kappler

    The Frontline 300 from Kappler is a high-performance protective ensemble engineered for petrochemical line breaks and high-heat industrial environments. Developed with direct input from petrochemical safety officers, the Frontline 300 provides an innovative, single-fabric solution for combined chemical and flash-fire protection, including exceptional radiant heat resistance.

    Incorporating the same proven chemical protection as Kappler’s Zytron 300 series, the Frontline 300 delivers excellent holdout against common petrochemical hazards while also shielding wearers from radiant heat during flash-fire scenarios. When tested using the Pyroman Thermal Manikin system at NC State University—replicating real-world conditions with 1900°F flames—the Frontline 300 ensemble demonstrated less than 1% predicted body burn, offering best-in-class survivability performance.

    Built on Kappler’s legacy of durability and field-proven protection, the Frontline 300 is a must-have ensemble for responders and technicians working in the most volatile petrochemical and high-heat situations.

    Features

    • Three-way protection for chemical, flash-fire and radiant heat.

    • Ideal for petrochemical line break operations developed with input from petrochemical safety officers.

    • Multi-use, single-exposure garment provides economical alternative to expensive reusable FR apparel.

    • Reinforced knee area for added confidence and work flexibility.

    Safe to use

    Proven with demanding Pyroman Thermal Manikin testing and The Frontline 300 ensemble garment indicated less than 1% body burn in 1900° temperatures.


    Multi-Protection

    Three-way protection for chemical, flash-fire and radiant heat and ideal for petrochemical line break operations developed with input from petrochemical safety officers.


    Unique Design

    Reinforced knee area for added confidence and work flexibility and offers “Splash and Flash” protection, plus excellent radiatn heat protection


    Specifications

    Chemical Test Battery

    Chemical Breakthrough time (min)
    Acetone >480
    Acetonitrile >480
    Carbon Disulfide >480
    Dichloromethane 10
    Diethylamine >480
    Dimethylformamide >480
    Ethyl Acetate >480
    n – Hexane >480
    Methyl Alcohol >480
    Nitrobenzene >480
    Sodium Hydroxide >480
    Sulfuric Acid >480
    Tetrachloroethylene >480
    Tetrahydrofuran >480
    Toluene >480

     

    Gas Breakthrough time (min)
    Ammonia Gas >480
    1,3 Butadiene Gas >480
    Chlorine Gas >480
    Ethylene Oxide Gas >480
    Hydrogen Chloride Gas >480
    Methyl Chloride Gas >480
    Other Chemicals Tested Breakthrough time (min)
    Benzene >480
    Diesel Fuel >480
    Diethylethanolamine >480
    Gasoline >480
    Hydrofluoric Acid (48%) >480
    Kerosene >480
    Methanol >480

    Chemical Warfare Agent Data

    Chemical Agent Breakthrough time Criteria
    Bis (2-chloroethyl) sulfide (Mustard:HD) >480 4.0 ug/cm2
    Isopropyl methylfluorophosphonate (Sarin:GB) >480 1.25 ug/cm2
    Chlorovinyl arsinedichloride (Lewisite:L) >240 4.0 ug/cm2
    O-ethyl S-(2-diisopropylaminoethyl) methylphosphonothiolate (Nerve:VX) >480 1.25 ug/cm2