Personal radiation detector · Hp(10) and H*(10) versions
A discreet and robust gamma radiation detector, designed for law enforcement and first responders to interdict nuclear and radioactive materials. It clips to the belt for the whole shift, alarms on a genuine threat, points you toward the source, and keeps measuring dose and dose rate when an event turns radiological.
Mirion states the AccuRad PRD was developed in close collaboration with state and federal law enforcement and first responders, to integrate into their routines. That shows in how it is carried: light, clipped on, readable without unclipping, and fed by ordinary AA cells.
The unit measures 4.25 x 2.4 x 1.4 in. (108 x 61 x 36mm) without clip and weighs 7 oz (200 g) including it. A tough, built-in belt clip fixes it securely to a belt or pocket, and the clip itself is a replaceable fiber-reinforced part.
A large front display for handheld work, plus a top display that enables hands-free visual readout and alarm assessment. Users can glance at a reading without removing the AccuRad PRD from their belt or pocket.
Comfortable for one-handed operation and usable with thick gloves and reduced visibility (gas mask). Mirion describes the controls as intuitive to use even without training, and device data is saved automatically with no operator action required.
A tool-less battery cover and commercially available cells: AA (LR6) 1.5 V alkaline, lithium 1.5 V (non-rechargeable) or NiMH 1.2 V (rechargeable). The USB-C port recharges NiMH cells; Mirion refers users to the operating manual when using different battery types.
Resistant to dust, sand and moisture, with shock resistance from the PRD body.
Not for explosive atmospheres. The AccuRad PRD is not certified for explosive atmospheres. Plan its use around your department's hazardous-location procedures.
An always-on detector is only useful if people trust its alarms. The AccuRad PRD uses Variable Background Suppression (VBS) so it can work in diverse background environments and trigger an alarm only for genuine threats or hazards.
The PRD triggers selectable audible, visual and/or vibration alarms, with one-touch alarm acknowledgment and automatic data recording.
Silent, on the body.
Bright LED alarm indicators.
85 dB(A) at 30 cm (11.8 in.).
Display messages.
For covert work. Discreet mode silences alarms for stealth applications: by default, the audible and visual alarms (LEDs) are deactivated while the vibration and display messages stay active. USB-C headphone connectivity adds a further level of stealth operation.
Besides dose rate or count rate, the PRD can show a simple unit-less 0–9 indicator. The default alert levels:
Default values; bar lengths show order, not scale. Device settings can be changed through the AccuRad app and the AccuRad Management center. Alarm actions on the device are suggestions and should not replace operator procedures and CONOPS.
Take it off the belt and switch to Search mode. Built-in directionality helps locate hot spots in busy environments, and with audible and vibration alarms on, the PRD chirps faster as you move closer to the source, so your eyes stay on the search.
Holding the PRD by hand, turn left or right to build the radar sectors.
Sectors indicate source intensity versus direction; black sectors and arrows indicate the direction.
Go in the direction of the black sectors and arrows to localize the source, then use the Trend screen to pin down a close-by source.
Count rate (Search mode): 0 cps to 160 000 cps. The radar is calibrated in the factory before delivery and ready to operate; a built-in radar calibration module is under Settings > Service > Radar Calib.
The AccuRad PRD pairs with a smartphone through the AccuRad app, giving real-time remote access to measurements and alarm history, plus data logging, batch processing, messaging and reachback to common operational data platforms.
For event security, Mirion suggests personnel in plain clothes consider carrying the PRD covertly in a pocket or backpack and getting alarms and dose rates through the AccuRad PRD smartphone application.
The app also bridges responders on the ground and command-center software with real-time geospatial and radiological data relay. The PRD is compatible with RadResponder, Sigma and SpirVIEW Mobile software.
The desktop software handles device configuration, maintenance, data retrieval and batch configuration of a fleet of devices. Communication needs no configuration: plug the AccuRad into the computer with a USB-C cable. Mirion states that hundreds of devices can be customized within minutes.
The AccuRad PRD comes in two versions that differ in the dose quantity they report and the standards they are rated to. Both work as a personal radiation detector and a body-worn dosimeter; the H*(10) version adds ambient dose equivalent for survey work.
Early warnings of hazardous radiation levels; search capabilities guide responders to locate and address radiation sources.
When body-worn, continuously provides dose rates and dose measurements and can trigger an alarm when exceeding a safety threshold.
The same early warnings and search capabilities as the Hp(10) version.
When body-worn, continuously provides dose rates and dose measurements and can trigger an alarm when exceeding a safety threshold.
Helps responders assess safe exposure limits and establish safe zones in public areas.
Near nuclear facilities, acts as a tissue-equivalent survey meter measuring up to 10 MeV. High-energy photon measurement compliant with IEC 60846-1.
Our listing covers the AccuRad PRD; name Hp(10) or H*(10) when you request a quote. On a unit in hand, check the startup screen or the calibration certificate: the H*(10) has an IEC 60846-1 compliant label in the battery compartment.
| Detection | |
|---|---|
| Detectors |
|
| CsI(Tl) sensitive volume | 10 mm (0.4 in.) diameter by 35 mm (1.4 in.) long |
| Radiation type | Photons (Gamma, X) |
| Energy range | Detects all radionuclides of concern, from 25 keV to 10 MeV; Dose rate response +/-25% from 55 keV to 10 MeV |
| Count rate (Search mode) | 0 cps to 160 000 cps |
| Units | Sv, rem, unit-less (0-9), cps (search mode) |
| Stabilization | Warm-up time: 35 seconds · No source required |
| IEC rated dose and dose rate range (for Cs-137) | |
| Low dose rate range (CsI) | 1 µrem/h to 100 mrem/h (0.01 µSv/h to 1 mSv/h). Minimum displayed 0.1 µrem/h (0.001 µSv/h) |
| High dose rate range (Diode) | 100 mrem/h to 1000 rem/h (1 mSv/h to 10 Sv/h) |
| Dose range | 10 µrem to 1000 rem. Minimum displayed 1 µrem |
| Dose rate linearity | +/-10 % from 10 µrem/h to 1000 rem/h (0.1 µSv/h to 10 Sv/h) |
| Dose linearity | +/-10% from 10 µrem to 1000 rem (0.1 µSv to 10 Sv) |
| Alarms | |
|---|---|
| Alarm response | Alarms at 50 µrem/h (0.5 µSv/h) within two seconds |
| VBS | Authenticates true alarms in variable backgrounds |
| False alarm rate | Less than two alarms per 8 hours in stable background (typically zero alarm per 24 hours) |
| Alarming | Vibration · Visual LED · Audible sound: 85 dB(A) at 30 cm (11.8 in.) |
| Discreet mode | Audible and visual (LED) alarms deactivated by default; vibration and display messages active. USB-C headphone connectivity. |
| Display and controls | |
| Modes of operation | Dose or count rate · Search with trend or radar · 0-9 display indicator |
| Display | Top display enables hands-free visual readout and alarm assessment · Reverse contrast option |
| Languages | Arabic, Chinese, English, French, German, Italian, Japanese, Korean, Polish and Spanish |
| Buttons and navigation | Intuitive to use even without training · Comfortable for one-handed operation · Usable with thick gloves and reduced visibility (gas mask) |
| Data | Device data automatically saved with no operator action required |
| Physical | |
|---|---|
| Weight | 7 oz (200 g), including clip |
| Size | 4.25 x 2.4 x 1.4 in. (108 x 61 x 36mm) without clip |
| Construction | Innovative heavy-duty bi-material construction · Replaceable fiber-reinforced clip |
| Environment | |
| Protection rating | IP67 (dust and 1 m (3 ft 3 in.) water immersion) |
| Temperature | -13 °F to 140 °F (-25 °C to 60 °C) |
| Drop | 1.5 m (4 ft 11 in.) on concrete |
| Shock and vibration | Temperature shocks and relative humidity according to ANSI/IEC standards · Vibration, impact according to ANSI/IEC standards |
| Explosive atmospheres | Not certified for explosive atmospheres |
| Power | |
| Battery | Two AA batteries for > 900 hours of continuous operation; Tool-less battery cover |
| Battery types |
|
| Power supply | USB-C (recharges NiMH) |
| Device | |
|---|---|
| Wireless | Bluetooth® Low Energy with Near Field Communications (NFC) pairing to smartphone |
| Wired | USB type C for earphones, maintenance and charging |
| Software | |
| Smartphone app | Android, iOS |
| App-enabled features | Remote display, settings, access to history and logs, batch configuration and updates |
| Reachback / streaming | Email, SMS, SpirVIEW Mobile software, RadResponder |
| Compatible platforms | RadResponder, Sigma, SpirVIEW Mobile software |
| Learning | Learning section with how-to videos and documentation |
| Desktop | AccuRad Management center: device configuration, maintenance, data retrieval and batch configuration over USB-C |
| Radioprotection standards by version | |
|---|---|
| AccuRad PRD Hp(10) | ANSI N42.32-2016, ANSI N42.20-2003, ANSI N42.17A |
| AccuRad PRD H*(10) | IEC 62401:2017, IEC 60846-1:2009, IEC 60846-2:2015 |
| Identifying the H*(10) | Startup screen or calibration certificate; IEC 60846-1 compliant label in the battery compartment |
| Supplied | |
| Standard | AccuRad PRD, AA alkaline batteries, quick guide, spare clip |
| Calibration | Calibration certificate provided with purchase of the AccuRad PRD |
Features, specifications, versions and standards.
PDF · Mirion ServiceOEM-certified service and support on every product we deliver. When a repair or calibration falls outside our in-house scope, we coordinate directly with the manufacturer and manage the logistics end to end.
Learn more SalesTell us the version (Hp(10) or H*(10)) and how your team will carry it, or call 210.566.1857.
Contact usRequest a quote on the Mirion AccuRad PRD. Let us know whether you need the Hp(10) or H*(10) version and how many responders will carry one.