    The TELEDYNE DETCON TP-700 is a fixed hydrogen sulfide sensor with solid-state technology designed for oil and gas, petrochemical, and wastewater treatment facilities.

    In stock

    or
    Add to Quote

    Model TP-700 is a non-intrusive “Smart” sensor designed to detect and monitor H2S in air over the range of 0-100 ppm using proprietary solid state metal oxide semiconductor technology. Features plug-in field replaceable detector with over-sized gold-plated connections, electro-polished 316 stainless steel housing, fully encapsulated electronics, and dual layer surge protection. Embedded intuitive software simplifies calibration, configuration, and diagnostics with built-in alpha/numeric display. Standard analog 4-20mA and Modbus RS-485 outputs with optional wireless SmartWireless integration. Equipped with explosion-proof certification (Class I Division 1), ATEX compliance, SIL2 certified, and 10-year conditional warranty on detector. Ideal for oil and gas drilling, production, refining, petrochemical, pulp and paper mills, and wastewater treatment.

    Description

    TP-700

    Model TP-700 is a non-intrusive “Smart” sensor designed to detect and monitor H2S in air over the range of 0-100 ppm using proprietary solid state metal oxide semiconductor technology. Features plug-in field replaceable detector with over-sized gold-plated connections, electro-polished 316 stainless steel housing, fully encapsulated electronics, and dual layer surge protection. Embedded intuitive software simplifies calibration, configuration, and diagnostics with built-in alpha/numeric display. Standard analog 4-20mA and Modbus RS-485 outputs with optional wireless SmartWireless integration. Equipped with explosion-proof certification (Class I Division 1), ATEX compliance, SIL2 certified, and 10-year conditional warranty on detector. Ideal for oil and gas drilling, production, refining, petrochemical, pulp and paper mills, and wastewater treatment.

    Features

    • LED Display with Antiglare Cover

    • Full Text Display Method

    • Non-intrusive Interface

    • Auto Zero/Auto Span

    • Pre-emptive Fault Diagnostics

    • Electropolished 316SS Construction

    • 100% Epoxy Encapsulated Circuitry

    • Bulletproof I/O Protection

    • Water-Proof, Corrosion-Proof, Vibration-Proof

    • Modular Design

    • Plug and Play Components

    • Quick Thread Release for Sensor Replacement

    • Integral Calibration Port

    • Wireless option compatible with SmartWireless product line

    • Remote Alarm Module (RAM) integration capability

    • HART integration option

    • Infinite shelf life

    • 10-year conditional warranty on plug-in detector

    Specifications

    Sensor Type
    Continuous diffusion/adsorption CHEMFET Solid State Metal Oxide Semiconductor, Plug-in field replaceable
    Sensor Life
    5 to 10 years typical
    Measurement Range
    0-20 ppm, 0-50 ppm, 0-100 ppm
    Accuracy/Repeatability
    ±10% of reading or ±2 ppm (greater of)
    Response/Clearing Time
    T50 <30 seconds; T80 <60 seconds
    Outputs
    Linear 4-20 mA DC, RS-485 MODBUS-RTU
    Electrical Classification
    Explosion proof CSA and US (NRTL) Class I, Division 1, Groups B, C, D (Tamb = -40°C to +75°C); ATEX II 2 G Ex d IIB + H2 T4 Gb (Tamb = -40°C to +70°C)
    Ingress Protection
    NEMA 4X, IP66
    Safety Approvals
    cCSAus, ATEX, CE Marking, SIL2 Certified to IEC 61508, Complies with ISA 92.01 Part 1-1998
    Warranty
    Plug-in detector – 10 year conditional; Transmitter – 2 Years
    Operating Temperature Range
    -40°F to +167°F; -40°C to +75°C
    Storage Temperature Range
    -31°F to +131°F; -35°C to +55°C
    Operating Humidity Range
    5-100% RH non-condensing
    Operating Pressure Range
    Atmospheric ±10%
    Dimensions (sensor only)
    7″H x 2.2″ Dia.; 178mmH x 65mm Dia.
    Dimensions (with junction box)
    11″H x 6.1″W x 3.75″D; 280mmH x 155mmW x 96mmD
    Mounting holes (J-box)
    5.5″; 140mm center to center
    Weight (sensor only)
    2 lbs; 0.907kg
    Weight (w/aluminum j-box)
    6 lbs; 2.72kg
    Weight (w/stainless steel j-box)
    9 lbs; 4.08kg
    Power Input
    11-30 VDC
    Power Consumption (normal)
    68mA (<1.7 watt)
    Power Consumption (maximum)
    85mA (2 watts)
    Inrush Current
    1.0A @ 24V
    RFI/EMI Protection
    Complies with EN50270
    Analog Output
    Linear 4-20mA DC (1,000 ohms max loop load @ 24VDC); 0mA All Fault Diagnostics; 2mA In-Calibration; 4-20mA 0-100% full-scale; 22mA Over-range condition
    Serial RS-485 Output
    RS-485 Modbus RTU
    Baud Rate
    9600 BPS (9600,N,8,1 Half Duplex)
    Status Indicators
    4-digit LED display with gas concentration, Full-script menu prompts
    Faults Monitored
    Heater, Loop, Input Voltage, Sensor, Processor, Memory, Calibration
    Cable Requirements (Power/Analog)
    3-wire shielded cable, Maximum distance 13,300 feet with 14 AWG
    Cable Requirements (Serial)
    2-wire twisted-pair shielded cable, Maximum distance 4,000 feet to last sensor
    I/O Protection
    Over-voltage, Miswiring, EMI/RFI Immunity