Tactical handheld radionuclide identification device (RID)
Symetrica designed the S100 to be compact, lightweight, and balanced for operators who may carry it through long shifts. It offers 14 hours of continuous operation to detect, locate, measure, and identify radioactive sources, with a NaI(Tl) gamma detector and, in the standard configuration S100-1N2, a 3He-free neutron detector.
Here is how the S100's figures line up with each stage of a radiological search, from switch-on to a confident result.
Symetrica states its Discovery Technology lets you "Switch on and operate in high radiation fields."
Dose rate is measured across a wide span, and the response stays continuous through temperature shock on a 1GHz CPU.
Symetrica states it "Identifies multiple isotopes simultaneously with high confidence" and "Identifies over 50 nuclides including masked and shielded cases."
Discovery Technology is credited with "High true-positive and low false-positive isotope identification", and Symetrica highlights "Exceptional detection capabilities for Special Nuclear Materials."
Symetrica describes Discovery Technology® as a combination of its hardware and patented algorithms, using on-board processing for spectral enhancement. The headline is effective resolution: the S100's NaI(Tl) detector is quoted at two figures for the same 662 keV 137Cs line.
Symetrica states that its advanced algorithms "enhance the effective resolution of the gamma detection system", for reliable low-level detection and fast, simultaneous identification of multiple and masked isotopes in challenging environments. It also states Discovery Technology is "deployed in thousands of systems globally from handheld RIIDs to fixed infrastructure Radiation Portal Monitors (RPM)."
Symetrica states Discovery Technology "outperforms other systems with the same scintillator by increasing the effective resolution of the deconvolution spectra during identification."
The standard configuration, S100-1N2 (Part # 400-0160), pairs a sodium iodide gamma detector with a lithium-6 neutron detector that needs no 3He. Configuration questions? Ask us.
Symetrica claims a class leading "Minimum Identifiable Amount" (MIA) using patented algorithms, with identification that exceeds ANSI N42.34.
Symetrica states the neutron detector "is free of 3He" and uses 6Li technology to achieve leading-class sensitivity.
Symetrica calls the S100 "the most mission-oriented handheld radionuclide identification device (RID)." These are the field claims behind that line.



The hard case appears in our listing photos; confirm what ships with your unit when you request a quote.
Symetrica claims "Up to 10 years of service without annual calibration", supported by automatic and continuous end-to-end digital calibration and health monitoring. Its patented stabilizing system is meant to keep the S100 at the same performance for up to 10 years.
Symetrica lists it as "Immune to temperature fluctuations and environmental conditions." Operating temperature is -20 to 50˚C (-4 to 122˚F), with IP67 ingress protection (IEC 60529).
An "Ergonomic and compact design for extended use": 29.2 x 11.8 x 11 cm (11.5 x 4.6 x 4.3 in) and 1.3 kg (2.9 lbs), with a 3.5 in. (8.9 cm) display.
An integrated Li-ion battery rated for 14 hrs of run time, plus Bluetooth, WiFi and USB-C communications. Symetrica cites "Low life-cycle costs due to continuous digital stabilization and health monitoring."
| Overview | |
|---|---|
| Mission | Search, Locate, Identify and Verify Radioactive Threats |
| Technology | Radioisotope identification device (RID) |
| Model | VeriFinder™ S100 |
| Standard configuration | S100-1N2 (Part # 400-0160) |
| Performance | |
| Identification | Exceeds ANSI N42.34 |
| Response time | Instant response to sources (0.2 s) with continuous operation through temperature shock with 1GHz CPU |
| Sampling time | User settable from a few seconds to 60 mins |
| Health status monitoring | Automatic and continuous end-to-end digital calibration and health monitoring |
| Gamma | |
|---|---|
| Detector type | NaI(Tl) |
| Detector volume | 43 cm3 (2.6 in3) |
| Effective resolution | 2.2% FWHM at 662 keV 137Cs |
| Raw resolution | <8% FWHM at 662 keV 137Cs |
| Energy range (gamma) | 25 keV - 3 MeV |
| Performance | Class leading 'Minimum Identifiable Amount' (MIA) using patented algorithms. |
| Dose | |
| Maximum dose for ID | 1 mSv/h (100mrem/h) |
| Dose rate measurement | 10 nSv/h to 900 mSv/h (1urem/h to 90 rem/h) |
| Neutron (standard configuration S100-1N2) | |
|---|---|
| Detector type | Li6F/ZnS |
| Detector size | 2.7 cm dia. X 11 cm (1" dia. X 4.3") |
| Capability | 252Cf 20,000 n/s @ 0.6 m/s @ 0.25 m (2 ft/s @ 10 in) |
| Energy range | 0.025 eV to 15MeV |
| Compliance | |
|---|---|
| Specifications | ANSI N42.34, ANSI N42.42, IEC 62327, IEC 62755 |
| Ingress protection | IP67 (IEC 60529) |
| Radiation safety | |
| Modes | Dosimeter / Mission Dose modes |
| Dose accuracy | Gamma dose accuracy of ± 10% for 137Cs |
| Neutron moderator | Inbuilt neutron moderator for handheld use enables ALARP (As Low As Reasonably Practicable) - Neutron model |
| Mechanical | |
|---|---|
| Dimensions | 29.2 x 11.8 x 11 cm (11.5 x 4.6 x 4.3 in) |
| Weight | 1.3 kg (2.9 lbs) |
| Electrical | |
| Battery | Integrated Li-ion |
| Run time | 14 hrs |
| Communications | Bluetooth, WiFi, USB-C |
| Display | 3.5 in. (8.9 cm) |
| Operational temperature | -20 to 50˚C (-4 to 122˚F) |
Key features, Discovery Technology and full specification.
PDF · Symetrica ServiceOEM-certified service and support on every product we deliver. When a repair or calibration falls outside our in-house scope, we coordinate directly with the manufacturer and manage the logistics end to end.
Repair Depot ConfigurationQuestions about the standard S100-1N2 configuration, kit contents or how the S100 fits your radiological program? Our team will get back to you.
Request a quoteCompact gamma & neutron radiation identifier.
Handheld RIID, high-resolution radiation detection.
Rugged backpack gamma & optional neutron radiation detector.
FarrWest is a pre-approved vendor on BuyBoard and Purchasing Cooperative of America (PCA). Government agencies can buy on competitively-bid cooperative contracts, with no lengthy RFP.
How co-op buying worksServiceOEM-certified service and support on every product we deliver: functional checks and certified calibration on the manufacturer’s required cycle, back in service in 48–72 hours typical.
Repair DepotSince 2004Serving Hazmat, Fire, Police, EMS, and Specialty Vehicle operations nationwide since 2004, with expert support, training, and service after the sale.
About FarrWestSide-by-side specifications and which model fits which job.
Open comparisonRelatedSymetrica VeriFinder S200 handheld RIID identifies multiple and masked isotopes with Discovery Technology, a 45 s cold start and GPS, Wi-Fi and…
View productRelatedSymetrica VeriFinder S300 puts a 3x3 in NaI gamma detector and optional 3He-free neutron on your back for hands-free search and isotope…
View productTell us about your mission and we will confirm configuration and kit contents for the Symetrica VeriFinder™ S100, then put a quote together.