Sensit Technologies P400 specialty toxic sensors detect hydrogen cyanide, chlorine, and sulfur dioxide for workers in hazardous locations requiring early warning detection.
SENSIT P400 multi-gas personal monitor featuring the Immediate Detection System (IDS) for early warning of dangerous gas level changes. Detects combustible gases and toxic gases including Hydrogen Cyanide (HCN), Chlorine (Cl2), and Sulfur Dioxide (SO2). Features large easy-to-read display, audible/vibration/visual alarms, STEL and TWA alarms, data logging, and simple field maintenance. Extremely rugged design with fast response times (<20 seconds for specialty sensors). Made in USA. UL913 approved for Class 1, Division 1 hazardous locations. Includes belt clip, calibration adapter, dust filters, batteries, and instruction manual.
| Performance | |
| HCN Resolution | 0.1ppm |
| HCN Range | 0-30 |
| HCN Accuracy | ±1ppm or 10% |
| HCN T90 Response | <20Sec |
| Cl2 Resolution | 0.1ppm |
| Cl2 Range | 0-20 |
| Cl2 Accuracy | ±1ppm or 10% |
| Cl2 T90 Response | <20Sec |
| SO2 Resolution | 0.1ppm |
| SO2 Range | 0-20 |
| SO2 Accuracy | ±1ppm or 10% |
| SO2 T90 Response | <20Sec |
| Power | |
| Power Source | 4 "AA" Alkaline or NiMH Recharger Pack |
| Battery Life | 24 Hr. Alkaline or 15 Hr. NiMH |
| Physical | |
| Size | 5.2" x 3.2" x 1.7" (13.2 x 8.1 x 4.0 cm) |
| Weight | 12 oz. (340 g) |
| Approvals & Warranty | |
| Certification | UL913 Class 1, Division 1, Groups A, B, C and D; ATEX Ex d ia IIC T4 |
| Other | |
| Operational Temperature | -4 to 122 F (-20 to 50° C) |
| Humidity | 10-90% RH (Non-condensing) |
| Sound | 98db @ 15" (30cm) |
Calibration, repair and maintenance for your detection instruments.