Level A and Level B use the same breathing protection. The difference is skin: Level A puts the wearer inside a gas-tight, totally encapsulating suit, while Level B only has to keep liquid off. Since January 2023, the NFPA standards that certify those suits live under one number, NFPA 1990, and the suffix on a style code now tells you which part of it a suit was certified to.
The letter levels come from Appendix B of OSHA's HAZWOPER standard, 29 CFR 1910.120. The appendix is guidance, not a mandate. It sorts PPE by how much respiratory and skin protection a site needs, and it says plainly that other combinations may fit the hazard better. It also tells employers to move up or down a level as they learn more about the site.
EPA/OSHA protection levels at a glance
| Level | Use it when (summary) | Breathing protection | Body protection |
|---|---|---|---|
| A | Highest skin, eye and respiratory protection is needed: high vapor concentrations, splash or immersion risk with skin-absorbed chemicals, or confined, poorly ventilated spaces not yet cleared | Positive-pressure full-facepiece SCBA, or positive-pressure supplied air with escape SCBA (NIOSH approved) | Totally-encapsulating chemical-protective suit, inner and outer chemical-resistant gloves, chemical-resistant steel toe and shank boots |
| B | Highest respiratory protection but less skin protection: IDLH inhalation hazard that is not a severe skin hazard, oxygen below 19.5%, or unidentified vapors that are not suspected skin hazards | Same as Level A | Hooded chemical-resistant clothing (coveralls, overalls and jacket, one- or two-piece splash suit), inner and outer gloves, outer chemical-resistant boots |
| C | Contaminants are identified and measured, will not harm exposed skin, and every criterion for air-purifying respirators is met | Full-face or half-mask air-purifying respirator (NIOSH approved) | Hooded chemical-resistant clothing, inner and outer gloves, chemical-resistant boots |
| D | No known atmospheric hazard and no chance of splash, immersion or unexpected chemical contact | None listed | Work uniform (coveralls, safety boots or shoes, safety glasses or splash goggles) |
Source: OSHA 29 CFR 1910.120 Appendix B, Parts A and B (summarised)
Two points from the appendix are easy to miss. First, Level A is also the default for confined or poorly ventilated spaces until the conditions that call for it have been ruled out. Second, OSHA notes that a suit material protects well against some chemicals and poorly against others, and that when nothing gives continuous protection, the material's breakthrough time should exceed the work time.
A common mistake is to treat "fully encapsulated" as "Level A." Encapsulation describes the shape. What makes a Level A suit is that it is gas-tight: a gas-tight zipper, sealed glove and valve interfaces, and a design that passes a pressure test. Kappler, for example, makes both kinds in the same Zytron 500 fabric. Its vapor suits have a gas-tight AquaSeal zipper and two exhaust valves. Its splash suits are also totally encapsulating but use a standard zipper and a single exhaust port.
Gas-tight and totally encapsulating, worn over the SCBA or with supplied air. Examples: the Zytron 500 vapor suits and the Frontline 500, which adds flash-fire testing.
Keeps liquid off the skin but is not built to stop vapor. It can be a coverall, a two-piece outfit or an encapsulating suit such as the Zytron 500 Z5H572. Non-encapsulating chemical coveralls and jackets, including DuPont Tychem 4000 and Tychem 6000, also sit in this space. Check the hood, gloves and fabric data against your chemicals.
Tested against chemical warfare agents (mustard and soman) as well as toxic industrial chemicals, in classes that step down in challenge level. A CBRN ensemble need not be encapsulating: the DuraChem 500 is a vapor-tight coverall that seals to the respirator face piece.
NFPA used to publish three separate hazmat clothing standards: NFPA 1991 for vapor-protective ensembles, NFPA 1992 for liquid-splash ensembles and NFPA 1994 for CBRN ensembles. NFPA 1990, Standard for Protective Ensembles for Hazardous Materials and CBRN Operations, merged them. Kappler gives its effective date as January 24, 2023, and its current manuals cite the 2022 edition. The old parts did not disappear. They became sections of NFPA 1990, so a label now reads "NFPA 1990 (1991)" or "NFPA 1990 (1994) Class 2". A companion standard, NFPA 1891, covers selection, care and maintenance.
According to Kappler's summary of the consolidation, the main technical changes were:
The parts of NFPA 1990 compared
| Part | Scope | Chemical test (garment, seams, visor, gloves, boots) | Challenge level | Whole-suit tests |
|---|---|---|---|---|
| NFPA 1990 (1991) | Vapor and liquid | Permeation, 1 hr vs 21 industrial chemicals, 4 toxic industrial chemicals, mustard and soman | Liquids 100 g/m2; vapors 100% | ASTM F1052 pressure; MIST PPDF > 488; shower > 60 min |
| NFPA 1990 (1992) | Liquid splash | Penetration, 1 hr vs 10 industrial chemicals (ASTM F903, visual) | 100% concentration, full contact | ASTM F1359 shower > 20 min |
| NFPA 1990 (1994) Class 1 | Vapor and liquid (CBRN) | Permeation, 1 hr vs 10 toxic industrial chemicals, mustard and soman | Liquids 20 g/m2; vapors 10,000 ppm | MIST PPDF > 441; shower > 20 min |
| NFPA 1990 (1994) Class 2/2R | Vapor and liquid (CBRN) | Permeation, 1 hr vs 5 toxic industrial chemicals, mustard and soman | Liquids 10 g/m2; vapors 350 ppm | MIST PPDF > 328; shower > 20 min |
| NFPA 1990 (1994) Class 3/3R | Vapor and liquid (CBRN) | Permeation, 1 hr vs 5 toxic industrial chemicals, mustard and soman | Liquids 10 g/m2; vapors 40 ppm | MIST PPDF ≥ 35; shower > 8 min |
| NFPA 1990 (1994) Class 4/4R | Particle | N/A | N/A | Shower > 4 min; particle inward leakage |
| NFPA 1990 (1994) Class 5 | Flammable gases not toxic to skin | Liquid repellency, ISO 6530, 4 non-toxic liquids | Low-level splash | Flash fire: ASTM F1358 12 sec burn and ASTM F2700 > 20 cal/cm2 |
Source: Kappler, "NFPA Standards: A Concise Reference Guide To NFPA Apparel Standards" (MM-0058, Aug 2025), p.2
How to read the table: the permeation pass mark for the (1991) part and Classes 1 to 3 is the same cumulative limit (6.0 µg/cm2 for industrial chemicals, 4.0 for mustard, 1.25 for soman). What changes is how hard the suit is challenged. The (1991) part also requires a pressure test and a flame-resistance test, and so does Class 1. In MIST (man-in-simulant test), a person in the suit works in a test vapor; a higher PPDF means less got inside. The "R" classes are ruggedized: the suit is laundered five times before MIST testing and must meet higher physical and flex/abrasion requirements. Kappler's chart shows flash-fire protection as optional for every part except Class 5.
OSHA's Appendix B still cites the old numbers, linking NFPA 1991 to Level A clothing and NFPA 1992 to Level B. Translate them to the matching NFPA 1990 part when you write a spec. The Zytron 500 vs DuraChem 500 vs Frontline 500 comparison shows which Kappler style is certified to which part.
Kappler vapor suits come in front, rear and front-diagonal entry with a gas-tight AquaSeal zipper under double storm flaps. Kappler says a rear-entry design improves frontal splash protection.
Field-replaceable gloves clamp to the sleeve with a steel clamp and PVC ring, so a damaged glove can be swapped in the field. Kappler's 2N1 glove system stops the inner glove turning inside out. Certified styles add a removable overglove. Kappler sizes gloves by hand circumference, so measure hands, not just height and weight.
Kappler codes these as separate garment types. An expanded back leaves room for an SCBA worn inside the suit. On its flat-back vapor styles, Kappler sells the pass-through separately. A NIOSH-approved pass-through is needed to connect an airline, and Kappler warns it is not a tether anchor.
Kappler's AntiFog Expanded-View visor is standard on its gas-tight suits. The anti-fog layer is permanent and is not meant to be replenished. Its Hazmat models add an FEP overlay. Kappler notes that the FEP lens contains PFAS (no PFOA or PFOS), even where the suit fabric does not.
Kappler vapor suits carry two exhaust valves under splash flaps; its splash suits have one exhaust port. The valves are also where the pressure-test adapters fit, so inspect them after every test. Replacement Pirelli exhalation valves are a service part.
Flash-fire protection is an option within NFPA 1990, not a default. The Frontline 500 is certified to NFPA 1990 (1991) with the optional flash-fire and liquefied gas requirements. Kappler reports 0% body burn in a six-second manikin test. Kappler limits it to escape from a chemical flash fire and says it is not for firefighting.
Also budget for outer chemical boots, since attached sock booties are not built to be walked on. Browse every style we carry in Hazmat Suits.
Drilling in a live suit wears it out. Training suits copy the cut instead. Kappler's Zytron 500 Z5S555 (front entry) and Z5S556 (rear entry) have an expanded back, large PVC visor, attached gloves and booties and one exhaust port. Their seams are serged rather than heat-sealed, and Kappler publishes no chemical data for them. The DuraChem 500 D5S457 and D5S458 do the same for the non-encapsulating CBRN coverall. They are for practice only.
Kappler also allows retired garments that are not contaminated to be labeled "For Training Use Only" with a permanent marker. Contaminated suits should be discarded, never reused for training. FarrWest's Hazmat Academy LMS and OEM-certified instructors cover this kind of hands-on suit work; see Training.
Kappler tells users to pressure test and fully inspect a vapor-protective suit at three points: on receipt or before first donning, after every wear before the suit goes back in service, and once a year. Its procedure mirrors ASTM F1052. Kappler notes that most other performance properties cannot be checked in the field.
Kappler's pressure test pass/fail points (ASTM F1052 method)
| Step | Pressure (inches of water column) | What happens |
|---|---|---|
| Inflate | 5.0 | Hold at least 3 minutes so wrinkles fill out and air temperature settles |
| Set test pressure | 4.0 | Bleed down, close the valve, start the timer |
| Read after 4 minutes | 3.2 or higher = pass | 3.2 equals the 20% drop the ASTM method allows; record the result in the inspection log |
Source: Kappler, User Information for Zytron and Frontline Level A Vapor Protective Garments (RM 00861) and Zytron 500 manual (RM 00867)
Kappler's Digital Pressure Test Kit AKMOC runs the test automatically. Non-encapsulating suits are not required to be pressure tested under NFPA 1891. Kappler still makes an AKM007 face-seal adapter so the DuraChem 500 can be checked the same way. If you would rather not run tests in-house, FarrWest's Service Program sends certified technicians on-site every 30 to 180 days for detector maintenance and pressure testing of Level A suits.
No. Level A needs a gas-tight, totally encapsulating suit. Many encapsulating suits are liquid-splash designs with a standard zipper and an exhaust port, which makes them Level B clothing. Look for a gas-tight zipper and a pressure-test procedure.
Breathing protection is the same: positive-pressure SCBA or supplied air with an escape bottle. Level A adds a vapor-tight suit for chemicals that are harmful to skin or absorbed through it. Level B covers atmospheres that are dangerous to breathe but not a severe skin hazard, including oxygen below 19.5%.
Its requirements live on as a part of NFPA 1990, which consolidated NFPA 1991, 1992 and 1994. Kappler gives the effective date as January 24, 2023. Certified suits are now labeled with the part, for example "NFPA 1990 (1991)" for vapor-protective ensembles.
It is a class within NFPA 1990 (1994). In Kappler's summary, Class 2 tests permeation against 5 toxic industrial chemicals plus mustard and soman at 10 g/m2 liquid and 350 ppm vapor. Class 1 raises that to 20 g/m2 and 10,000 ppm. Class 3 lowers the vapor challenge to 40 ppm.
Kappler's guidance for its vapor suits: on receipt or before first use, after every wear before reuse, and at least annually, along with a full visual inspection each time.
Kappler rates its Zytron, Frontline and DuraChem 500 garments at 10 years from the date of manufacture if stored between 40 and 90 °F, dry, out of UV and with the zipper open. Other makers set their own shelf life.
Tell us the mission, the threats you face and how your team works. We’ll recommend equipment and send a quote, on BuyBoard or PCA if your agency uses them.