No products in the cart.

    DrägerSensor XXS Cl2

    $655.00

    DrägerSensor XXS Cl2 is a replaceable electrochemical chlorine sensor for monitoring hazardous gases in food, chemical, pulp and paper, power generation, and water treatment facilities.

    or
    Add to Quote

    DrägerSensor XXS Cl2 is a replaceable electrochemical sensor designed for monitoring hazardous gas concentrations in ambient air. Compatible with Dräger Pac 8000, X-am 5000, and X-am 8000 gas detection devices. Features excellent linearity, fast response times (≤30 seconds), and broad measurement range. Suitable for food and beverage, chemical manufacturing, pulp and paper, power generation, sewage treatment, and water treatment applications. Expected sensor life exceeds 2 years with 1-year warranty.

    Description

    DrägerSensor XXS Cl2

    DrägerSensor XXS Cl2 is a replaceable electrochemical sensor designed for monitoring hazardous gas concentrations in ambient air. Compatible with Dräger Pac 8000, X-am 5000, and X-am 8000 gas detection devices. Features excellent linearity, fast response times (≤30 seconds), and broad measurement range. Suitable for food and beverage, chemical manufacturing, pulp and paper, power generation, sewage treatment, and water treatment applications. Expected sensor life exceeds 2 years with 1-year warranty.

    Features

    • Detects chlorine, bromine, fluorine, and chlorine dioxide

    • Excellent linearity

    • Fast response time (≤30 seconds)

    • Wide operating temperature range (-40 to 50°C)

    • Low detection limit (0.05 ppm)

    • Compatible with multiple Dräger gas detection devices

    • Replaceable sensor cartridge

    Specifications

    Order no.
    6810890
    Detection limit
    0.05 ppm
    Resolution
    0.05 ppm
    Measurement range (Cl2)
    0 to 20 ppm
    Measurement range (F2)
    0 to 20 ppm
    Measurement range (Br2)
    0 to 20 ppm
    Measurement range (ClO2)
    0 to 20 ppm
    Relative sensitivity (Cl2)
    1.00
    Relative sensitivity (F2)
    1.00
    Relative sensitivity (Br2)
    1.00
    Relative sensitivity (ClO2)
    0.60
    Response time
    ≤30 seconds (t90)
    Sensitivity
    ≤±2% of measured value
    Zero point drift (20°C)
    ≤±0.2 ppm/year
    Sensitivity drift
    ≤±2% of measured value/month
    Warm-up time
    ≤30 minutes
    Operating temperature
    (-40 to 50)°C
    Operating humidity
    (10 to 90)% RH
    Operating pressure
    (700 to 1,300) hPa
    Temperature influence – Zero point
    ≤±0.05 ppm
    Temperature influence – Sensitivity
    ≤±5% of measured value
    Humidity influence – Zero point
    No effect
    Humidity influence – Sensitivity
    ≤±0.4% of measured value/%RH
    Test gas
    approx. 1 to 18 ppm Cl2
    Expected sensor life
    >2 years
    Guaranty
    1 year
    Plug&Play
    no
    Replaceable
    yes

    CONTACT US