100 ppm Isobutylene / balance Air calibration gas from Portagas, supplied in 5 cylinder options: 34 L (34DS), 58 L (58GAL), M300, BUMP, 17 L (17DS). NIST-traceable, filled to Portagas specification.
Hazmat item. Hazardous material (compressed calibration gas, UN1956). Ships FedEx Ground only within the U.S. — no air or expedited service and no PO boxes. A flat hazmat handling fee is added once per order, or choose free local pickup at one of our Texas offices at checkout and no fee applies.
100 ppm Isobutylene / balance Air calibration gas from Portagas, supplied in 5 cylinder options: 34 L (34DS), 58 L (58GAL), M300, BUMP, 17 L (17DS). NIST-traceable, filled to Portagas specification.
Use with a Portagas fixed-flow or demand-flow regulator (sold separately) to bump-test and calibrate portable and fixed gas detectors. The leading number of a cylinder code is its nominal volume in litres.
Isobutylene is the standard reference gas for calibrating photoionization detectors (PIDs), the sensors used to measure volatile organic compounds. A PID calibrated on isobutylene reports in isobutylene units, and correction factors then convert readings to other VOCs. A 100 ppm mix in balance air is a common span point for that calibration and for daily bump tests.
The same 100 ppm isobutylene / balance air mixture comes in five cylinder options. Where the code starts with a number, that number is the nominal volume in liters.
Larger cylinders run more bump tests and calibrations before a swap. Every fill is NIST-traceable and made to Portagas specification. Connect it through a Portagas fixed-flow or demand-flow regulator, sold separately, for portable or fixed detectors.
Compressed calibration gas is a regulated hazardous material, UN1956, Class 2.2. It ships by FedEx Ground only, and local pickup is available at FarrWest’s Texas and Colorado offices. For PID instruments that need more than a span check, the FarrWest Repair Depot issues calibration certificates tied to each instrument’s serial number.
It is used to bump test and calibrate gas detectors, most commonly photoionization detectors (PIDs) that measure volatile organic compounds. Isobutylene is the usual PID reference gas, and this Portagas mix is 100 ppm isobutylene in balance air, NIST-traceable.
Use a Portagas fixed-flow or demand-flow regulator, sold separately. The regulator connects the cylinder to your portable or fixed gas detector for bump testing and calibration. The same regulator choice applies to all five cylinder options of this mix.
Yes. Compressed calibration gas is regulated as UN1956, Class 2.2. This cylinder ships by FedEx Ground only, and it can be picked up locally at FarrWest's Texas or Colorado offices instead of shipping it to your agency.
Hazmat item. Hazardous material (compressed calibration gas, UN1956). Ships FedEx Ground only within the U.S. — no air or expedited service and no PO boxes. A flat hazmat handling fee is added once per order, or choose free local pickup at one of our Texas offices at checkout and no fee applies.
| Cylinder | 34 L (34DS), 58 L (58GAL), M300, BUMP, 17 L (17DS) |