No products in the cart.

  • Symetrica · Gamma + neutron RID

    Symetrica VeriFinder™ S100

    Tactical handheld radionuclide identification device (RID)

    Symetrica designed the S100 to be compact, lightweight, and balanced for operators who may carry it through long shifts. It offers 14 hours of continuous operation to detect, locate, measure, and identify radioactive sources, with a NaI(Tl) gamma detector and, in the standard configuration S100-1N2, a 3He-free neutron detector.

    Over 50nuclides, incl. masked & shielded
    14 hrsrun time
    1.3 kg(2.9 lbs)
    IP67IEC 60529
    Symetrica VeriFinder S100 handheld radionuclide identifier with its colour display showing a gamma detection event
    VeriFinder™ S100 · Search, locate, identify and verify
    Mission

    Search, locate, identify and verify

    Here is how the S100's figures line up with each stage of a radiological search, from switch-on to a confident result.

    01 · Search

    Switch on and sweep

    Symetrica states its Discovery Technology lets you "Switch on and operate in high radiation fields."

    Response time
    Instant response to sources (0.2 s)
    02 · Locate

    Close in on the source

    Dose rate is measured across a wide span, and the response stays continuous through temperature shock on a 1GHz CPU.

    Dose rate measurement
    10 nSv/h to 900 mSv/h (1urem/h to 90 rem/h)
    03 · Identify

    Name the isotopes

    Symetrica states it "Identifies multiple isotopes simultaneously with high confidence" and "Identifies over 50 nuclides including masked and shielded cases."

    Sampling time
    User settable from a few seconds to 60 mins
    Maximum dose for ID
    1 mSv/h (100mrem/h)
    04 · Verify

    Trust the call

    Discovery Technology is credited with "High true-positive and low false-positive isotope identification", and Symetrica highlights "Exceptional detection capabilities for Special Nuclear Materials."

    Identification
    Exceeds ANSI N42.34
    Discovery Technology®

    Same crystal, sharper answer

    Symetrica describes Discovery Technology® as a combination of its hardware and patented algorithms, using on-board processing for spectral enhancement. The headline is effective resolution: the S100's NaI(Tl) detector is quoted at two figures for the same 662 keV 137Cs line.

    Illustration of a broad raw peak at less than 8 percent FWHM and a narrow effective peak at 2.2 percent FWHM, both at 662 keV 2.2% FWHMeffective <8% FWHMraw 662 keV · 137Cs Energy →
    Illustration only.
    <8%Raw resolution · FWHM at 662 keV 137Cs
    2.2%Effective resolution · FWHM at 662 keV 137Cs

    Symetrica states that its advanced algorithms "enhance the effective resolution of the gamma detection system", for reliable low-level detection and fast, simultaneous identification of multiple and masked isotopes in challenging environments. It also states Discovery Technology is "deployed in thousands of systems globally from handheld RIIDs to fixed infrastructure Radiation Portal Monitors (RPM)."

    What Symetrica says it delivers

    • High true-positive and low false-positive isotope identification.
    • Identification of masked isotopes that cannot normally be resolved when analyzing raw spectra.
    • Fully functional and accurate operation through temperature shock.
    • Switch on and operate in high radiation fields.
    • Reliable and scalable 3He-free neutron detection even in high gamma exposed fields.
    • Predictive maintenance and no annual calibration required.

    Symetrica states Discovery Technology "outperforms other systems with the same scintillator by increasing the effective resolution of the deconvolution spectra during identification."

    Gamma + neutron

    Two detectors, one grip

    The standard configuration, S100-1N2 (Part # 400-0160), pairs a sodium iodide gamma detector with a lithium-6 neutron detector that needs no 3He. Configuration questions? Ask us.

    Gamma · identification
    NaI(Tl)

    Symetrica claims a class leading "Minimum Identifiable Amount" (MIA) using patented algorithms, with identification that exceeds ANSI N42.34.

    Detector volume
    43 cm3 (2.6 in3)
    Energy range
    25 keV - 3 MeV
    Effective resolution
    2.2% FWHM at 662 keV 137Cs
    Raw resolution
    <8% FWHM at 662 keV 137Cs
    Neutron · S100-1N2
    Li6F/ZnS

    Symetrica states the neutron detector "is free of 3He" and uses 6Li technology to achieve leading-class sensitivity.

    Detector size
    2.7 cm dia. X 11 cm (1" dia. X 4.3")
    Capability
    252Cf 20,000 n/s @ 0.6 m/s @ 0.25 m (2 ft/s @ 10 in)
    Energy range
    0.025 eV to 15MeV
    Radiation safety
    • Dosimeter / Mission Dose modesTrack exposure on the instrument.
    • Gamma dose accuracy± 10% for 137Cs.
    • Inbuilt neutron moderatorFor handheld use, enabling ALARP (As Low As Reasonably Practicable) on the neutron model.
    Designed for the operator in the field

    Built for the long shift

    Symetrica calls the S100 "the most mission-oriented handheld radionuclide identification device (RID)." These are the field claims behind that line.

    VeriFinder S100 seated in its charging and data offload dock with a green status light
    VeriFinder S100 charging & data offload dock
    Front view of the VeriFinder S100 with wrist lanyard and dose readout on screen
    Front view
    VeriFinder S100 held in one hand
    In hand
    VeriFinder S100 packed in a hard carry case with charger leads
    Shown in hard case

    The hard case appears in our listing photos; confirm what ships with your unit when you request a quote.

    • 01

      No annual calibration

      Symetrica claims "Up to 10 years of service without annual calibration", supported by automatic and continuous end-to-end digital calibration and health monitoring. Its patented stabilizing system is meant to keep the S100 at the same performance for up to 10 years.

    • 02

      Immune to temperature and environmental conditions

      Symetrica lists it as "Immune to temperature fluctuations and environmental conditions." Operating temperature is -20 to 50˚C (-4 to 122˚F), with IP67 ingress protection (IEC 60529).

    • 03

      Compact, light and balanced

      An "Ergonomic and compact design for extended use": 29.2 x 11.8 x 11 cm (11.5 x 4.6 x 4.3 in) and 1.3 kg (2.9 lbs), with a 3.5 in. (8.9 cm) display.

    • 04

      Power and data

      An integrated Li-ion battery rated for 14 hrs of run time, plus Bluetooth, WiFi and USB-C communications. Symetrica cites "Low life-cycle costs due to continuous digital stabilization and health monitoring."

    Specifications

    S100 specifications

    Standard configuration S100-1N2 (Part # 400-0160)
    Overview
    MissionSearch, Locate, Identify and Verify Radioactive Threats
    TechnologyRadioisotope identification device (RID)
    ModelVeriFinder™ S100
    Standard configurationS100-1N2 (Part # 400-0160)
    Performance
    IdentificationExceeds ANSI N42.34
    Response timeInstant response to sources (0.2 s) with continuous operation through temperature shock with 1GHz CPU
    Sampling timeUser settable from a few seconds to 60 mins
    Health status monitoringAutomatic and continuous end-to-end digital calibration and health monitoring
    Gamma
    Detector typeNaI(Tl)
    Detector volume43 cm3 (2.6 in3)
    Effective resolution2.2% FWHM at 662 keV 137Cs
    Raw resolution<8% FWHM at 662 keV 137Cs
    Energy range (gamma)25 keV - 3 MeV
    PerformanceClass leading 'Minimum Identifiable Amount' (MIA) using patented algorithms.
    Dose
    Maximum dose for ID1 mSv/h (100mrem/h)
    Dose rate measurement10 nSv/h to 900 mSv/h (1urem/h to 90 rem/h)
    Neutron (standard configuration S100-1N2)
    Detector typeLi6F/ZnS
    Detector size2.7 cm dia. X 11 cm (1" dia. X 4.3")
    Capability252Cf 20,000 n/s @ 0.6 m/s @ 0.25 m (2 ft/s @ 10 in)
    Energy range0.025 eV to 15MeV
    Compliance
    SpecificationsANSI N42.34, ANSI N42.42, IEC 62327, IEC 62755
    Ingress protectionIP67 (IEC 60529)
    Radiation safety
    ModesDosimeter / Mission Dose modes
    Dose accuracyGamma dose accuracy of ± 10% for 137Cs
    Neutron moderatorInbuilt neutron moderator for handheld use enables ALARP (As Low As Reasonably Practicable) - Neutron model
    Mechanical
    Dimensions29.2 x 11.8 x 11 cm (11.5 x 4.6 x 4.3 in)
    Weight1.3 kg (2.9 lbs)
    Electrical
    BatteryIntegrated Li-ion
    Run time14 hrs
    CommunicationsBluetooth, WiFi, USB-C
    Display3.5 in. (8.9 cm)
    Operational temperature-20 to 50˚C (-4 to 122˚F)
    FAQ

    Common questions

    Does the VeriFinder S100 detect neutrons as well as gamma?
    Yes, in its standard configuration. Symetrica lists the standard configuration as S100-1N2 (Part # 400-0160), which carries a Li6F/ZnS neutron detector alongside the NaI(Tl) gamma detector. The neutron detector is free of 3He and uses 6Li technology. For configuration questions, ask us.
    Does it need annual calibration?
    Symetrica states the S100 offers "Up to 10 years of service without annual calibration", backed by automatic and continuous end-to-end digital calibration and health monitoring, and describes "Predictive maintenance and no annual calibration required." Talk to us about service and calibration planning.
    How many isotopes can it identify?
    Symetrica states it "Identifies over 50 nuclides including masked and shielded cases" and "Identifies multiple isotopes simultaneously with high confidence." Identification performance is listed as exceeding ANSI N42.34.
    Which standards does it meet, and what ingress protection does it have?
    The specification lists ANSI N42.34, ANSI N42.42, IEC 62327, IEC 62755, and ingress protection of IP67 (IEC 60529). Operating temperature is -20 to 50˚C (-4 to 122˚F).
    How is it powered and how do I get data off it?
    An integrated Li-ion battery rated for 14 hrs of run time. Communications are Bluetooth, WiFi and USB-C, and the S100 has a charging & data offload dock.
    Next step

    Search, identify, verify

    Tell us about your mission and we will confirm configuration and kit contents for the Symetrica VeriFinder™ S100, then put a quote together.

    CONTACT US