No products in the cart.

  • 908 Devices · Handheld FTIR gas identifier

    XplorIR

    Accurate, actionable gas identification

    Gas-phase FTIR in your hand. XplorIR pulls the air sample through a 1.8 meter multi-pass gas cell, reads its infrared fingerprint and matches it against a library of 5,600+ gases and vapors, with detection in under 30 seconds. Monitor an area continuously, or point and shoot at a single target.

    “XplorIR® is the only handheld gas/vapor detector that can accurately detect, identify, and quantify over 5,600 chemical threats in seconds.”908 Devices · quantification with the Quantification Package
    5,600+Gases & vapors
    < 30Seconds, detection time
    Up to 6Components in a mixture
    IP 54Dust; Waterproof/Resistant
    908 Devices XplorIR handheld FTIR gas identifier, red housing, with a hydrogen cyanide identification on its screen
    How it identifies

    From a breath of air to a name

    XplorIR is built on FTIR (Fourier Transform Infrared Spectroscopy), applied to gases and vapors. Four steps run inside the instrument every time it takes a reading.

    Pump 1 l/min
    Step 01

    Draw the sample

    An active sample pump pulls the surrounding gas or vapor into the instrument, so the reading comes from the air in front of you.

    Sample pump: Active, 1 l/min
    Sample type: Gases/Vapors
    1.8 m path Multi-pass cell · 38ml
    Step 02

    Long-path gas cell

    Infrared light crosses the sample inside a long-path, multi-pass gas cell, and XplorIR delivers part per million (ppm) level sensitivity.

    Gas measurement: 1.8 meters, multi-pass gas cell, 38ml volume
    Wavenumber Spectrum
    Step 03

    Read the fingerprint

    Each product shows up as unique spectral features. XplorIR uses adaptive atmospheric corrections to adjust to background atmospheric conditions, so the fingerprint is not lost in the air around it.

    Technology: FTIR (Fourier Transform Infrared Spectroscopy)
    Library match 5,600+ entries
    Step 04

    Match the library

    The spectrum is matched against the library of 5,600+ gases and vapors. XplorIR provides accurate ID of up to 6 components in real-time, even within complex gas mixtures.

    Detection time: < 30 seconds
    On screenClear, visible results in seconds, with simple operation.
    Behind the resultThreat Assist: an integrated chemical information database.
    Backup24/7/365 Reachback with data analysis from 908 Devices.
    The threat library
    5,600+
    Gases & vapors in the library

    One instrument, from chemical warfare agents to everyday industrial solvents. XplorIR can continuously monitor 5,600+ gas/vapors with part per million (ppm) level sensitivity.

    Class

    Chemical Warfare Agents

    • Nerve Agents
    • Blister Agents
    • Choking Agents
    Class

    Hazardous Chemicals

    • TICs
    • TIMs
    • VOCs
    Library coverage
    • TICs
    • CWAs
    • VOCs
    • WMDs
    • Industrial Chemicals
    • Solvents
    • Hydrocarbons

    Threat Assist, an integrated chemical information database, is built into the instrument.

    Two ways to work

    Watch the room, or point and shoot

    The same instrument covers a whole environment or a single suspect source, and it keeps up when the air holds more than one chemical at a time.

    Responder in a protective suit and respirator holding an XplorIR near laboratory glassware
    XplorIR in a responder's hands
    Mode

    Continuous monitoring

    Use XplorIR to continuously monitor environments, watching the air for any of the 5,600+ gases and vapors in its library while the team works.

    Mode

    Point and shoot

    Or operate in point-and-shoot mode for isolated target intelligence: aim at a single suspect source and get a result in under 30 seconds.

    6
    Complex mixtures

    Accurate ID of up to 6 components in real-time, even within complex gas mixtures, so a blend of vapors is named component by component.

    Add-on · Quantification Package

    Know what it is. Then know how much.

    Identification tells you what is in the air. The optional XplorIR Quantification Package adds the concentration, in ppm, reported alongside the product identity.

    01
    Detect

    Is a hazardous gas or vapor present at the incident?

    02
    Identify

    What is the product? Matched against 5,600+ gases and vapors.

    Package03
    Quantify

    How much of the hazard exists in the atmosphere, at the part-per-million (ppm) level.

    XplorIR screen listing three identified compounds, 2-propanol, toluene and acetone, each with a ppm reading
    A three-compound result with ppm values
    “FTIR measurements are inherently quantitative, and the spectral response is linear with respect to product concentration.”908 Devices

    With the Quantification Package, XplorIR uses a reference library based on known chemical concentrations to report the ppm of a product along with its identity, for thousands of hazardous chemicals. No user calibration required.

    Once the concentration is known, the XplorIR software lets you compare it to the product's IDLH (Immediately Dangerous to Life and Health) level, for rapid tactical decisions about remediation and decon with just a few button clicks. It can identify and quantify up to 6 mixture components at one time.

    Add-on for XplorIR

    XplorIR Quantification Package

    Simultaneously Identify and Quantify Hazardous Gases and Vapors
    • Quantify multiple components at the part-per-million (ppm) level
    • Identify up to 6 mixture components simultaneously
    • No user calibration required
    View package
    In the field

    Carried in, wiped down after

    XplorIR is designed for use in harsh environments: rated Dust; Waterproof/Resistant; IP 54, cleaned with bleach or detergent, and connected back to the team.

    Responder in SCBA, hood and gloves reading an XplorIR beside boxes and a paint can
    Operated by a responder in SCBA
    • 01

      Rugged, IP 54

      Dust; Waterproof/Resistant; IP 54. Operates from 0 to 50° C (32 to 122° F) and 0-95% non-condensing humidity.

    • 02

      Simple decon

      Spray or wipe-down with bleach or detergent.

    • 03

      Carry and run time

      5.5 lbs (2.49 kgs), with a rechargeable Li Ion battery rated for 6 hours.

    • 04

      Connected to the team

      GPS and WiFi (802.11 G) on board. The Team Leader App is available for download on iOS, Android, and Windows devices for remote data access.

    • 05

      Expert backup

      24/7/365 Reachback with data analysis, 24/7/365 Support and a 1 Year Warranty from 908 Devices.

    Specifications

    The numbers

    Measurement
    TechnologyFTIR (Fourier Transform Infrared Spectroscopy)
    Sample typeGases/Vapors
    Gas measurement1.8 meters, multi-pass gas cell, 38ml volume
    Sample pumpActive, 1 l/min
    Detection time< 30 seconds
    SensitivityPart per million (ppm) level sensitivity
    MixturesProvides accurate ID of up to 6 components in real-time even within complex gas mixtures.
    Libraries
    Libraries5,600+ Gases & Vapors
    TICs, CWAs, VOCs, WMDs, Industrial Chemicals, Solvents, Hydrocarbons
    DatabaseThreat Assist; integrated chemical information database
    Physical
    Size12.5" X 6.5" X 5.75" (31.75cm X 16.51cm X 14.61cm)
    Weight5.5 lbs (2.49 kgs)
    RuggednessDust; Waterproof/Resistant; IP 54
    DeconSpray or wipe-down with bleach or detergent
    Environment
    Operating temperature0 to 50° C (32 to 122° F)
    Operating humidity0-95% non-condensing
    Power
    Battery life6 hours
    PowerRechargeable Li Ion battery
    Connectivity
    Connections
    • GPS
    • WiFi (802.11 G)
    Remote data accessTeam Leader App available for download on iOS, Android, and Windows devices
    Support
    Warranty / support
    • 1 Year Warranty
    • 24/7/365 Support
    • Reachback with data analysis
    XplorIR Quantification Package (add-on)
    FunctionSimultaneously Identify and Quantify Hazardous Gases and Vapors
    Key attributes
    • Adaptively adjust to background atmospheric conditions
    • Reliably detect products based on unique spectral features
    • Identify up to 6 mixture components simultaneously
    • Quantify multiple components at the part-per-million (ppm) level
    • No user calibration required
    ListingXplorIR Quantification Package

    XplorIR is subject to export controls including those of the Export Administration Regulations of the U.S. Department of Commerce, which may restrict or require licenses for the export of product from the United States and their reexport to and from other countries.

    FAQ

    Questions we get on the phone

    What can XplorIR identify?
    Its library holds 5,600+ gases and vapors, including chemical warfare agents (nerve, blister and choking agents) and hazardous chemicals (TICs, TIMs and VOCs). Library coverage includes TICs, CWAs, VOCs, WMDs, Industrial Chemicals, Solvents and Hydrocarbons.
    How fast does it give a result?
    Detection time is < 30 seconds, with clear, visible results on screen.
    Can it handle a mixture of gases?
    Yes. XplorIR provides accurate ID of up to 6 components in real-time, even within complex gas mixtures.
    Does every XplorIR measure concentration?
    Concentration comes from the XplorIR Quantification Package, an add-on. With it, XplorIR reports the ppm of a product along with its identity for thousands of hazardous chemicals, with no user calibration required, and the software lets you compare the reading to the product's IDLH level. Tell us whether you need quantification when you request a quote.
    How rugged is it, and how do I decon it?
    It is designed for use in harsh environments and rated Dust; Waterproof/Resistant; IP 54, operating from 0 to 50° C (32 to 122° F) and 0-95% non-condensing humidity. Decon is spray or wipe-down with bleach or detergent.
    How long does the battery last?
    Battery life is 6 hours on a rechargeable Li Ion battery.
    Can results be shared off the instrument?
    XplorIR has GPS and WiFi (802.11 G). For remote data access, the Team Leader App is available for download on iOS, Android, and Windows devices.
    What warranty and support come with it?
    908 Devices lists a 1 Year Warranty, 24/7/365 Support, and Reachback with data analysis.
    Next step

    Put FTIR in your team's hands

    Tell us what you respond to and whether you need the Quantification Package. We will come back with a quote for XplorIR.

    CONTACT US