No products in the cart.

    • PM1402M
    • PM1402M — view 2
    • PM1402M — view 3
    • PM1402M — view 4
    • PM1402M — view 5
    Polimaster

    PM1402M

    The POLIMASTER PM1402M is a portable radiation detection device for field personnel to detect, locate, and identify radioactive materials in real time.

    Request a quote
    Quotes typically returned within 1 business day.
    or
    Add to Quote
    Questions? Talk to a specialist210.566.1857 · sales@farrwest.com
    Measurement range of alpha radiation flux
    1-5×10⁵ cm⁻²min⁻¹
    Battery lifetime (BD-05)
    20 h
    Weight (BD-05)
    310 g
    Dimensions (BD-05)
    64×40×118 mm
    Environmental temperature range
    -30 to +50°C

    Overview

    The PM1402M is a multipurpose portable radiation detection device designed for field use to measure parameters of all types of ionizing radiation and to detect, locate and identify radioactive and special nuclear materials in real time. Features include a 512-channel gamma-ray spectrometer, nonvolatile memory for storage of up to 110 measured spectra, RS-232 port for PC data transmission, hermetic shockproof housing, and interchangeable detector modules (BD-01 through BD-05) for gamma, neutron, and alpha/beta radiation detection. Meets drop test (0.7m concrete) and sea fog test standards. IP67 protection rating. Operates on five AA NiCd rechargeable batteries with 20-100 hour runtime depending on detector configuration.

    • Detection and location of radioactive and special nuclear materials
    • Real-time identification of radiation sources
    • 512-channel gamma-ray spectrometer
    • Storage of up to 110 measured spectra
    • RS-232 port for data transmission to PC
    • 1 m extension tube for detectors

    Specifications

    Performance
    Detector (BD-05)Proportional counter with a mica window
    Measurement range of alpha radiation flux1-5×10⁵ cm⁻²min⁻¹
    Measurement range of beta radiation flux10-10⁶ cm⁻²min⁻¹
    Cutoff energy range of beta radiation0.15-3.5 MeV
    Sensitivity for alpha radiation (239Pu)2 counts/cm²
    Sensitivity for beta radiation (90Sr+90Y)0.5 counts/cm²
    Flux threshold range alpha radiation1-5×10⁵ cm⁻²min⁻¹
    Flux threshold range beta radiation10-10⁶ cm⁻²min⁻¹
    Accuracy of alpha radiation measurement (5.15 MeV, 239Pu)±(20+10/φ)%
    Accuracy of beta radiation measurement (90Sr+90Y)±(20+100/φ)%

    Calibration & repair from FarrWest

    Calibration, repair and maintenance for your detection instruments.

    Service programs →Scheduled calibration & maintenanceRepair depot →Start a repairTraining →Courses for your team

    CONTACT US