The AEMC Model 6416 is a clamp-on ground resistance tester for measuring grounding systems without auxiliary rods or disconnection.
The Ground Resistance Tester Model 6416 measures ground rod and grid resistance and impedance without the use of auxiliary rods. This clamp-on ground resistance tester can be used in multi-grounded systems without disconnecting or de-energizing the ground system under test. The Model 6416 simply clamps around the grounding electrode or conductor and measures the resistance to ground. By performing measurements on intact ground systems, the user verifies the quality of grounding connections and bonds. Resistance and continuity of grounding loops around pads and buildings may also be measured. Features include OLED display with 152 segments, 300 measurement memory, adjustable alarms, current measurement capabilities, loop inductance measurement, and contact voltage calculation. Suitable for ground testing, ground rod testing, earth ground testing, ground continuity testing, and ground wire testing applications.
| Performance | |
| Ground Resistance Measurement Range (Auto-Ranging 1 to 199Ω) | 0.010 to 1500 Ω |
| Ground Resistance Measurement - 0.010 to 0.099 Ω Resolution | 0.001 Ω |
| Ground Resistance Measurement - 0.010 to 0.099 Ω Accuracy | ±(1.5%Reading +0.01 Ω) |
| Ground Resistance Measurement - 0.10 to 0.99 Ω Resolution | 0.01 Ω |
| Ground Resistance Measurement - 0.10 to 0.99 Ω Accuracy | ±(1.5%Reading +0.02 Ω) |
| Ground Resistance Measurement - 1 to 49.9 Ω Resolution | 0.1 Ω |
| Ground Resistance Measurement - 1 to 49.9 Ω Accuracy | ±(1.5% Reading +0.1 Ω) |
| Ground Resistance Measurement - 50.0 to 99.5 Ω Resolution | 0.5 Ω |
| Ground Resistance Measurement - 50.0 to 99.5 Ω Accuracy | ±(2% Reading +0.5 Ω) |
| Ground Resistance Measurement - 100 to 199 Ω Resolution | 1 Ω |
| Ground Resistance Measurement - 100 to 199 Ω Accuracy | ±(3% Reading +1 Ω) |
| Ground Resistance Measurement - 200 to 395 Ω Resolution | 5 Ω |
| Ground Resistance Measurement - 200 to 395 Ω Accuracy | ±(5% Reading +5 Ω) |
| Ground Resistance Measurement - 400 to 590 Ω Resolution | 10 Ω |
| Ground Resistance Measurement - 400 to 590 Ω Accuracy | ±(10% Reading +10 Ω) |
| Ground Resistance Measurement - 600 to 1150 Ω Resolution | 50 Ω |
| Ground Resistance Measurement - 600 to 1150 Ω Accuracy | 20% approx |
| Ground Resistance Measurement - 1200 to 1500 Ω Resolution | 50 Ω |
| Ground Resistance Measurement - 1200 to 1500 Ω Accuracy | 25% approx |
| Alarm | Adjustable from (1 to 199) Ω |
| Current Measurement Range - 0.200 to 0.999 mA Resolution | 1 µA |
| Current Measurement Range - 0.200 to 0.999 mA Accuracy | ±(2 % Reading +50 µA) |
| Current Measurement Range - 1.000 to 2.990 mA Resolution | 10 µA |
| Current Measurement Range - 1.000 to 2.990 mA Accuracy | ±(2 % Reading +50 µA) |
| Current Measurement Range - 3.00 to 9.99 mA Resolution | 10 µA |
| Current Measurement Range - 3.00 to 9.99 mA Accuracy | ±(2 % Reading +50 µA) |
| Current Measurement Range - 10.00 to 29.99 mA Resolution | 100 µA |
| Current Measurement Range - 10.00 to 29.99 mA Accuracy | ±(2 % Reading +100 µA) |
| Current Measurement Range - 30.0 to 99.9 mA Resolution | 100 µA |
| Current Measurement Range - 30.0 to 99.9 mA Accuracy | ±(2 % Reading +100 µA) |
| Current Measurement Range - 100 to 299.9 mA Resolution | 1 mA |
| Current Measurement Range - 100 to 299.9 mA Accuracy | ±(2 % Reading +1 mA) |
| Current Measurement Range - 0.300 to 0.990 A Resolution | 1 mA |
| Current Measurement Range - 0.300 to 0.990 A Accuracy | ±(2 % Reading +1 mA) |
| Current Measurement Range - 1.000 to 2.999 A Resolution | 10 mA |
| Current Measurement Range - 1.000 to 2.999 A Accuracy | ±(2 % Reading +10 mA) |
| Current Measurement Range - 3.00 to 39.99 A Resolution | 10 mA |
| Current Measurement Range - 3.00 to 39.99 A Accuracy | ±(2 % Reading +10 mA) |
| Loop Inductance Measurement - 10 to 100 µH Resolution | 1 µH |
| Loop Inductance Measurement - 10 to 100 µH Accuracy | ±(5 % Reading +1 µH) |
| Loop Inductance Measurement - 100 to 500 µH Resolution | 1 µH |
| Loop Inductance Measurement - 100 to 500 µH Accuracy | ±(3 % Reading +1 µH) |
| Display | OLED, 152 segments (48x39) mm |
| 3 Alarms | Ω, V and A |
| Power | |
| Contact Voltage (Touch Voltage) Calculated - 0.1 to 4.9 V Resolution | 0.1 V |
| Contact Voltage (Touch Voltage) Calculated - 0.1 to 4.9 V Accuracy | ±(5 % Reading +0.1 V) |
| Contact Voltage (Touch Voltage) Calculated - 5.0 to 49.5 V Resolution | 0.5 V |
| Contact Voltage (Touch Voltage) Calculated - 5.0 to 49.5 V Accuracy | ±(5 % Reading +0.5 V) |
| Contact Voltage (Touch Voltage) Calculated - 50 to 75.0 V Resolution | 1 V |
| Contact Voltage (Touch Voltage) Calculated - 50 to 75.0 V Accuracy | ±(10 % Reading +1 V) |
| Power Source | (4) x1.5 V LR6 (AA) alkaline batteries or 4 NiMH batteries |
| Battery Life | 12 h or 1440 30-seconds tests approx |
| Weight (with Battery) | 2.06 lbs (935 g) |
| Physical | |
| Dimensions | (2.16 x 3.74 x 10.31) in (55 x 95 x 262) mm |
| Connectivity | |
| Memory | 300 measurements |
| Approvals & Warranty | |
| Ingress Protection (IP) | IP 40 |
| Safety Compliance | IEC 61010-1, EN 61010-2-30, EN 61010-2-32, Pollution Degree 2, 600 V CAT IV |
| Other | |
| Model | 6416 |
| Cat. # | 2141.01 |
| Frequency Selection | Choice of (50, 60, 128, or 2083) Hz for impedance calculation |
| Maximum Overload | Permanent current: 100 max. 50/60 Hz; Transient current: (<5 s) 200A 50/60 Hz |
| Jaw Opening | 1.38 in (35 mm) max |
| Operating Temperature | (-4 to +131) °F (-20 to +55) °C |
| Storage Temperature | (-22 to +158) °F (-30 to +70) °C |
| Relative Humidity | Up to 90 % @ 40 °C |
| EMC | EN 61326-1 |