    Compact electrochemical sensor designed for low-concentration hydrogen sulfide (H₂S) detection with a measuring range of 0-100 ppm. Enables selective and accurate detection of H₂S even at concentrations below 1 ppm, ideal for industrial hygiene, confined space monitoring, firefighting, and emergency response. Compatible with Dräger Pac, X-am1/2/5, and X-am8000 devices. Features exceptional long-term stability, rapid response times (≤15 seconds), and can last up to 5 years with minimal calibration requirements.

    Description

    DrägerSensor XXS H2S / H2S LC

    Compact electrochemical sensor designed for low-concentration hydrogen sulfide (H₂S) detection with a measuring range of 0-100 ppm. Enables selective and accurate detection of H₂S even at concentrations below 1 ppm, ideal for industrial hygiene, confined space monitoring, firefighting, and emergency response. Compatible with Dräger Pac, X-am1/2/5, and X-am8000 devices. Features exceptional long-term stability, rapid response times (≤15 seconds), and can last up to 5 years with minimal calibration requirements.

    Features

    • Compact electrochemical sensor for hydrogen sulfide detection

    • Accurate measurement of H₂S below 1 ppm

    • Fast response time for early detection

    • Strong selectivity reducing false readings

    • Miniaturized XXS design with high sensitivity

    • Exceptional long-term stability

    • Compatible with Dräger Pac, X-am1/2/5, and X-am8000 devices

    • Low operating costs with extended sensor life up to five years

    • Rare calibration requirements

    Specifications

    Detection Limit
    0.4 ppm
    Resolution
    0.1 ppm
    Measurement Range
    0 to 100 ppm H2S (hydrogen sulfide)
    Response Time
    ≤ 15 seconds (T90)
    Sensitivity
    ≤ ± 5% of measured value
    Long-term drift Zero point (at 20°C / 68°F)
    ≤ ± 0.2 ppm/year
    Long-term drift Sensitivity
    ≤ ± 5% of measured value/year
    Warm up time
    ≤ 5 minutes
    Temperature Range
    (–40 to 50)°C (–40 to 122)°F
    Humidity Range
    (10 to 90)% RH
    Pressure Range
    (700 to 1,300) hPa
    Temperature influence Zero point
    No effect
    Temperature influence Sensitivity
    ≤ ± 5% of measured value
    Humidity influence Zero point
    No effect
    Humidity influence Sensitivity
    ≤ ± 0.1% of measured value/% RH
    Test gas
    approx. 5 to 90 ppm H2S

    CONTACT US