No products in the cart.

    • PoliPack GN-S
    • PoliPack GN-S — view 2
    • PoliPack GN-S — view 3
    Polimaster

    PoliPack GN-S

    The PoliPack GN-S is a spectroscopic gamma-neutron backpack detector for radiation surveys and emergency response personnel requiring rapid radionuclide identification.

    Request a quote
    Quotes typically returned within 1 business day.
    or
    Add to Quote
    Questions? Talk to a specialist210.566.1857 · sales@farrwest.com
    Gamma radiation energy range
    30 keV to 3 MeV
    Battery lifetime
    ≥ 72 h
    Ingress protection
    IP67
    Dimensions
    360 × 320 × 164 mm
    Operating temperature
    –20 °С to 50 °С

    Overview

    The PoliPack™ GN-S is a gamma-neutron Backpack-Based Radiation Detection System equipped with spectroscopic gamma detectors for identifying radionuclides. Carried in a compact backpack and controlled remotely via wired control unit or smartphone app (Polismart®). Features include ANSI N42.53-2021 and IEC 62694:2022 compliance, radionuclide identification in under 1 minute, dose rate measurement range 0.05-30 µSv/h, 72-hour battery life, IP67 rating, and optional extended range detector. Ideal for radiation surveys, contamination mapping, critical infrastructure security, public events, and emergency services.

    • ANSI N42.53-2021 and IEC 62694:2022 compliance
    • ANSI N42.42 format data transmission
    • Indication of the direction to the source
    • Radionuclides identification in less than 1 minute
    • Categorization of identified radionuclides
    • Adjustable radionuclide libraries

    Specifications

    Performance
    Detectorgamma Csl(TI) SiPM; neutron 6LiF/ZnS
    Dose rate measurement range0.05 µSv/h to 30 µSv/h (built-in detectors); 0.05 µSv/h to 10 Sv/h (with extended range detector)
    Dose rate measurement accuracy± 30 %
    Gamma radiation energy range30 keV to 3 MeV
    Gamma radiation sensitivity2100 cps per µSv/h (137Cs); 15000 cps per µSv/h (241Am)
    Neutron radiation energy rangethermal to 15 MeV
    Neutron radiation sensitivity75 cps⋅cm2 (for 252Cf in 4 cm HDPE capsule at 1.5 m)
    Neutron count rate indication range0.01 cps to 9999 cps
    Alarms (in the remote control)visual, audible, vibration
    Atmospheric pressure84 kPa to 106.7 kPa

    Calibration & repair from FarrWest

    Calibration, repair and maintenance for your detection instruments.

    Service programs →Scheduled calibration & maintenanceRepair depot →Start a repairTraining →Courses for your team

    CONTACT US