  • Honeywell RAE Systems / Model PGM-6228

    MultiRAE

    Wireless portable six-gas monitor with advanced VOC detection capability

    A pumped multi-gas monitor you build around the job from 25 intelligent interchangeable sensor options, including PID for VOCs, NDIR for combustibles and CO2, and electrochemical sensors for toxic gases and oxygen. Six readings require the CO + H2S combination sensor, which reads both CO and H2S from a single sensor position. Honeywell positions it for industrial hygiene, personal protection, leak detection and HazMat response.

    25Sensor options
    0–5,000 ppmPID range, 0.1 ppm res.
    IP-65Ingress rating
    31 oz880 g, pumped
    Honeywell MultiRAE in its yellow rubber boot, display showing OXY, LEL, CO, H2S and 10.6 eV VOC readings
    Front view · 10.6 eV PID unit
    Sensors

    Six readings. Twenty-five sensors.

    The MultiRAE family can display readings from one to six sensors, depending on the configuration. Below are the 25 sensor options, grouped into five families, with range and resolution. Sensors marked “Sold separately” also have their own product page as replacement parts.

    Six readings

    Six readings take the CO + H2S combo sensor

    A two-gas combination sensor is required for a 6-gas configuration. That sensor is the carbon monoxide (CO) + hydrogen sulfide (H2S) combo. That one sensor reads both CO and H2S from a single sensor position.

    The unit pictured above reads oxygen, LEL, CO, H2S and VOC.

    Example: six readings from five sensors — the CO + H2S combo sensor supplies two of them. Illustration.

    PID · VOCs

    1 sensor

    Photoionization detection for volatile organic compounds. The PID sensor requires a pumped configuration; this model has a built-in pump.

    SensorRangeResolutionProduct page
    VOC 10.6 eV (ext. range)0 to 5,000 ppm0.1 ppm
    On-board library: 190 VOCs

    Catalytic LEL

    1 sensor

    Combustible gas as a percentage of the lower explosive limit.

    SensorRangeResolutionProduct page
    Catalytic LEL0 to 100% LEL1% LELSold separately →
    On-board library: 55 combustible gases

    NDIR · infrared

    3 sensors

    Non-dispersive infrared for methane, as %LEL or %Vol., and for carbon dioxide.

    SensorRangeResolutionProduct page
    NDIR (0-100% LEL methane)0 to 100% LEL1% LELSold separately →
    NDIR (0-100% Vol. methane)0 to 100% Vol.0.1% Vol.
    Carbon dioxide (CO2) NDIR0 to 50,000 ppm100 ppm

    Oxygen

    2 sensors

    Electrochemical oxygen sensors, standard or Liq O2.

    SensorRangeResolutionProduct page
    Oxygen (O2)0 to 30% Vol.0.1% Vol.Sold separately →
    Oxygen (Liq O2)0 to 30% Vol.0.1% Vol.

    Electrochemical · toxic gases

    18 sensors

    Electrochemical sensors for toxic gases. The CO + H2S combo reads both gases from one sensor position.

    SensorRangeResolutionProduct page
    Carbon monoxide (CO)0 to 500 ppm1 ppmSold separately →
    Carbon monoxide (CO), ext. range0 to 2,000 ppm10 ppm
    Carbon monoxide (CO), H2-comp.0 to 2,000 ppm10 ppm
    CO + hydrogen sulfide (H2S) comboReads CO and H2S from a single sensor position. Required for six readings.0 to 500 ppm (CO) /
    0 to 200 ppm (H2S)
    1 ppm (CO) /
    0.1 ppm (H2S)
    Hydrogen sulfide (H2S)0 to 100 ppm0.1 ppmSold separately →
    Ammonia (NH3)0 to 100 ppm1 ppmSold separately →
    Chlorine (Cl2)0 to 50 ppm0.1 ppmSold separately →
    Chlorine dioxide (ClO2)0 to 1 ppm0.03 ppm
    Ethylene oxide (EtO-A)0 to 100 ppm0.5 ppm
    Ethylene oxide (EtO-B)0 to 10 ppm0.1 ppm
    Formaldehyde (HCHO)0 to 10 ppm0.05 ppm
    Hydrogen cyanide (HCN)0 to 50 ppm0.5 ppm
    Methyl mercaptan (CH3-SH)0 to 10 ppm0.1 ppm
    Nitric oxide (NO)0 to 250 ppm0.5 ppm
    Nitrogen dioxide (NO2)0 to 20 ppm0.1 ppm
    Phosphine (PH3)0 to 20 ppm0.1 ppm
    Phosphine (PH3 H)0 to 20 ppm0.1 ppm
    Sulfur dioxide (SO2)0 to 20 ppm0.1 ppmSold separately →
    1. Rule 01 · Six readingsSix readings require the CO + H2S combination sensor, which reads both CO and H2S from a single sensor position.
    2. Rule 02 · PIDThe PID sensor requires a pumped configuration. The MultiRAE has a built-in pump.
    3. Rule 03 · %Vol. NDIRIf a %Vol. NDIR sensor is installed, a catalytic bead %LEL sensor must also be installed for CSA certification.
    4. Rule 04 · No empty slotsIf you remove a sensor and do not replace it, a MultiRAE “dummy” sensor must be installed in that slot.
    5. Rule 05 · Field swapsIntelligent sensors store calibration data, so they can be swapped in the field. RAE Systems recommends calibrating sensors on installation.
    In the field

    Built for the hose-down, read in any hand

    Honeywell calls the MultiRAE highly versatile and customizable. The body that carries those sensors is rated dust-tight and protected against water jets, and the display turns itself the right way up.

    Three-quarter view of the Honeywell MultiRAE showing the rubber boot grip pads
    Three-quarter view · protective rubber boot
    • 01

      IP-65 ingress protection rating

      Dust-tight and waterproof against hosing jets coming from all directions.

    • 02

      MIL-STD-810G and 461F compliant

      Performance tests also include LEL CSA C22.2 No. 152 and ISA-12.13.01.

    • 03

      -4° to 122°F (-20° to 50°C)

      Operating temperature, at 0% to 95% relative humidity (non-condensing).

    • 04

      Monochrome graphical LCD, 128 x 160

      Backlit, with an automatic screen “flip” feature. Readout includes STEL, TWA, peak and minimum values, and the PID measurement gas and correction factor.

    • 05

      19 languages

      Arabic, Chinese, Czech, Danish, Dutch, English, French, German, Indonesian, Italian, Japanese, Korean, Norwegian, Polish, Portuguese, Russian, Spanish, Swedish and Turkish.

    Applications

    Where Honeywell puts it to work

    • Industrial hygiene
    • Personal protection
    • Leak detection
    • HazMat response
    • Aviation (wing tank entry)
    • Chemical
    • Environmental
    • Oil and gas
    • Pharmaceutical
    • Shipping/marine
    • Clandestine drug labs
    Alarms

    Five ways to know

    Unmistakable five-way local and remote wireless notification of alarm conditions, including Man Down Alarm. Alarm mode is your choice: Auto Reset or Latched.

    • 01

      Audible

      95 dB @ 30 cm.

    • 02

      Vibration

      Vibration alert.Disabled whenever the alkaline adapter is used.

    • 03

      Visible

      Flashing bright red LEDs.

    • 04

      On-screen

      On-screen indication of alarm conditions.

    • 05

      Wireless remote

      Wireless remote alarm notification, on units ordered with the optional wireless capability.

    Side profile of the Honeywell MultiRAE showing the belt clip
    Man Down Alarm

    A 3D gravity sensor that notices when you stop moving

    The MultiRAE has a 3D gravity sensor that can track the slightest motion of the instrument in any direction. Man Down Alarm comes with a pre-alarm and real-time remote wireless notification. These are the default settings:

    1. Setting
      Off / On

      Off by default.

    2. Motionless time
      30 s

      By default.

    3. Warning time
      30 s

      By default.

    4. Alarm
      Pre-alarm + alarm

      With real-time remote wireless notification.

    Note: when a MultiRAE is connected to an AutoRAE 2, truck mount, or desktop cradle, the Man Down alarm feature is disabled.

    Wireless (optional)

    Readings at the command post

    Wireless and non-wireless configurations are available. With the optional built-in RF modem, commanders and safety officers get real-time access to instrument readings and alarm status from any location, for better situational awareness and faster incident response.

    Wireless range (typical)
    1. MultiRAE to EchoView Host, RAEMesh Reader or RAEPoint~660 ft (200 m)
    2. MultiRAE to RAELink3 Mesh modem~330 ft (100 m)
    3. MultiRAE to Wi-Fi Access Point~330 ft (100 m)
    0 ft330 ft660 ft

    Typical ranges. Additional equipment and/or software licenses may be required to enable remote wireless monitoring and alarm transmission.

    • Networks

      ProRAE Guardian or EchoView Host

      ProRAE Guardian Real-Time Wireless Safety System, or EchoView Host-based Closed-Loop System.

    • Radio

      Sub 1GHz mesh + Wi-Fi

      ISM license free band. IEEE 802.15.4 Sub 1GHz, Wi-Fi 802.11 b/g. Supports RM900A.

    • Short range

      Integrated BLE modem (optional)

      Up to 15 ft (5 m) for BLE.

    • Fleet

      Honeywell SafetySuite

      Device Management with Honeywell SafetySuite.

    Power & upkeep

    Swap the pack, keep the shift

    The MultiRAE battery packs are plug-and-play and can be replaced on the go without tools. Three power options, and the consumables we stock to keep it running.

    Rear of the Honeywell MultiRAE showing the belt clip and the plug-in battery pack
    Rear view · plug-in battery pack below the belt clip
    1. Extended duration Li-ion~18-hr. runtime · < 9-hr. recharge
    2. Rechargeable Li-ion~12-hr. runtime · < 6-hr. recharge
    3. Alkaline adapter, 4 x AA~6-hr. runtime

    Runtimes are for non-wireless monitors. The alkaline adapter takes four AA alkaline batteries (use only Duracell MN1500); alkaline batteries cannot be recharged, and the vibration alarm is disabled whenever the alkaline adapter is used.

    • Bump & calibrate

      AutoRAE 2

      Fully automatic bump testing and calibration with AutoRAE 2, or manual calibration. Policy enforcement can require calibration and/or bump tests at set intervals (disabled by default).

    • Interval

      At least every 180 days

      The MultiRAE must be calibrated if it does not pass a bump test, or at least once every 180 days, depending on use and sensor exposure to poisons and contaminants.

    • Datalogging

      6 months, 5 sensors

      Continuous datalogging at 1-minute intervals, 24/7, with user-configurable intervals from 1 to 3,600 seconds. Data are retained in non-volatile memory.

    • Pump service

      Authorized personnel only

      Only authorized personnel should replace the pump, and any attempt to change it yourself voids the warranty. Contact Honeywell or your Honeywell Distribution Center, or ask our Repair Depot how we can help.

    Specifications

    Key specifications

    Model PGM-6228.

    Physical
    ModelPGM-6228. Wireless and non-wireless configurations are available.
    Size7.6" H x 3.8" W x 2.6" D (193 x 96.5 x 66 mm)
    Weight31 oz (880 g)
    SamplingBuilt-in pump. Average flow rate: 250 cc/min. Auto shutoff in low-flow conditions
    Display & controls
    DisplayMonochrome graphical LCD display (128 x 160) with backlighting. Automatic screen “flip” feature.
    Display readoutReal-time reading of gas concentrations; PID measurement gas and correction factor; Man Down Alarm on/off; visual compliance indicator; battery status; datalogging on/off; wireless on/off and reception quality. STEL, TWA, peak, and minimum values
    Keypad buttons3 operation and programming keys (Mode, Y/+, and N/-)
    LanguagesArabic, Chinese, Czech, Danish, Dutch, English, French, German, Indonesian, Italian, Japanese, Korean, Norwegian, Polish, Portuguese, Russian, Spanish, Swedish, and Turkish
    Environment
    Operating temperature-4° to 122°F (-20° to 50°C)
    Humidity0% to 95% relative humidity (non-condensing)
    Dust & water resistanceIP-65 ingress protection rating (dust-tight and waterproof against hosing jets coming from all directions)
    Performance testsMIL-STD-810G and 461F compliant. LEL CSA C22.2 No. 152; ISA-12.13.01
    25 intelligent interchangeable field-replaceable sensors including PID for VOCs, electrochemical sensors for toxic gases and oxygen, combustible LEL and NDIR sensors, and CO2 NDIR sensor
    SensorRangeResolution
    PID
    VOC 10.6 eV (ext. range)0 to 5,000 ppm0.1 ppm
    Combustible
    Catalytic LEL0 to 100% LEL1% LEL
    NDIR (0-100% LEL methane)0 to 100% LEL1% LEL
    NDIR (0-100% Vol. methane)0 to 100% Vol.0.1% Vol.
    Carbon dioxide
    Carbon dioxide (CO2) NDIR0 to 50,000 ppm100 ppm
    Toxic & oxygen
    Ammonia (NH3)0 to 100 ppm1 ppm
    Carbon monoxide (CO)0 to 500 ppm1 ppm
    Carbon monoxide (CO), ext. range0 to 2,000 ppm10 ppm
    Carbon monoxide (CO), H2-comp.0 to 2,000 ppm10 ppm
    CO + hydrogen sulfide (H2S) combo0 to 500 ppm (CO) / 0 to 200 ppm (H2S)1 ppm (CO) / 0.1 ppm (H2S)
    Chlorine (Cl2)0 to 50 ppm0.1 ppm
    Chlorine dioxide (ClO2)0 to 1 ppm0.03 ppm
    Ethylene oxide (EtO-A)0 to 100 ppm0.5 ppm
    Ethylene oxide (EtO-B)0 to 10 ppm0.1 ppm
    Formaldehyde (HCHO)0 to 10 ppm0.05 ppm
    Hydrogen cyanide (HCN)0 to 50 ppm0.5 ppm
    Hydrogen sulfide (H2S)0 to 100 ppm0.1 ppm
    Methyl mercaptan (CH3-SH)0 to 10 ppm0.1 ppm
    Nitric oxide (NO)0 to 250 ppm0.5 ppm
    Nitrogen dioxide (NO2)0 to 20 ppm0.1 ppm
    Oxygen (O2)0 to 30% Vol.0.1% Vol.
    Oxygen (Liq O2)0 to 30% Vol.0.1% Vol.
    Phosphine (PH3)0 to 20 ppm0.1 ppm
    Phosphine (PH3 H)0 to 20 ppm0.1 ppm
    Sulfur dioxide (SO2)0 to 20 ppm0.1 ppm

    A two-gas combination sensor is required for a 6-gas configuration. The CO + H2S combo reads both CO and H2S from a single sensor position.

    Power
    Battery options, runtime & recharge
    • Rechargeable Li-ion (~12-hr. runtime, < 6-hr. recharge time)
    • Extended duration Li-ion (~18-hr. runtime, < 9-hr. recharge time)
    • Alkaline adapter with 4 x AA batteries (~6-hr. runtime)
    Specification for non-wireless monitors.
    Battery part numbersStandard duration rechargeable Li-ion battery (PN: M01-3053-000); extended-duration rechargeable Li-ion battery (PN: M01-3055-000); alkaline battery pack for four standard AA-sized batteries (PN: M01-3054-000)
    Alarms & calibration
    AlarmsWireless remote alarm notification; audible (95 dB @ 30 cm), vibration, visible (flashing bright red LEDs), and on-screen indication of alarm conditions. Man Down Alarm with pre-alarm and real-time remote wireless notification
    CalibrationAutomatic with AutoRAE 2 Test and Calibration System or manual
    Data
    DataloggingContinuous datalogging (6 months for 5 sensors at 1-minute intervals, 24/7). User-configurable datalogging intervals (from 1 to 3,600 seconds)
    Communication & data downloadData download and instrument set-up and upgrades on PC via desktop charging and PC comm. cradle, travel charger, or AutoRAE 2 Automatic Test and Calibration System. Wireless data and alarm status transmission via built-in RF modem (optional)
    Wireless networkProRAE Guardian Real-Time Wireless Safety System or EchoView Host-based Closed-Loop System
    Wireless range (typical)
    • MultiRAE to RAELink3 [Z1] Mesh modem ~330 feet (100 meters)
    • MultiRAE to EchoView Host, RAEMesh Reader or RAEPoint ~660 feet (200 meters)
    • MultiRAE to Wi-Fi Access Point ~330 feet (100 meters)
    Wireless frequencyISM license free band. IEEE 802.15.4 Sub 1GHz, Wi-Fi 802.11 b/g
    Radio moduleSupports RM900A
    Wireless approvalsFCC Part 15
    BLEIntegrated BLE Modem (Optional); up to 15 ft (5 m) for BLE

    Additional equipment and/or software licenses may be required to enable remote wireless monitoring and alarm transmission.

    Safety certifications
    CSAClass I, Division 1, Groups A, B, C and D, T4
    Class II, Division 1; Groups E, F, G; T85°C
    ATEXII 1G Ex ia IIC T4 Ga
    2G Ex ia d IIC T4 Gb with IR Sensor installed
    I M1 Ex ia I Ma
    IECExEx ia IIC T4 Ga
    Ex ia d IIC T4 Gb with IR Sensor installed
    I M1 Ex ia I Ma
    IECEx / ANZExEx ia IIC T4 Ga; Ex ia d IIC T4 Gb with IR Sensor installed; Ex ia I Ma
    Warranty
    Manufacturer warranty
    • Four years on Liq O2 sensors
    • Three years on CO and H2S sensors
    • Two years on non-consumable components and catalytic LEL sensors
    • One year on all other sensors, battery, and other consumable parts
    Standard contents
    • Monitor with sampling mode, sensors, battery, and wireless options as specified and protective rubber boot, external filter, and belt clip installed
    • Travel Charger/PC communications adapter
    • AC adapter
    • Alkaline battery adapter
    • PC communication cable
    • Calibration adapter
    • 6" flexible probe
    • 3 spare external filters
    • 10 charcoal filters (reduce CO sensor’s cross-sensitivity to VOCs)
    • PID sensor cap removal tool
    • Toolkit
    • QuickStart Guide
    • Calibration and test certificate
    • Hard transport case
    FAQ

    Questions we get on the phone

    How many gases can one MultiRAE monitor at once?
    Up to six, and six readings require the CO + H2S combination sensor, which reads both CO and H2S from a single sensor position. A two-gas combination sensor is required for a 6-gas configuration. The MultiRAE family can display readings from one to six sensors (including dual sensor), depending on the configuration.
    Is wireless standard?
    No, it is optional. Wireless and non-wireless configurations are available. The optional built-in RF modem works with ProRAE Guardian or EchoView Host networks, Wi-Fi is 802.11 b/g, and an integrated BLE modem is also optional. Additional equipment and/or software licenses may be required to enable remote wireless monitoring and alarm transmission.
    Can I swap sensors myself?
    Yes. Intelligent sensors store calibration data, so they can be swapped in the field; RAE Systems recommends calibrating sensors on installation, and you should always calibrate the MultiRAE after replacing the sensor module. A slot cannot be left empty: if you remove a sensor without replacing it, install a MultiRAE “dummy” sensor.
    How long does the battery last?
    Rechargeable Li-ion: ~12-hr. runtime, < 6-hr. recharge time. Extended duration Li-ion: ~18-hr. runtime, < 9-hr. recharge time. Alkaline adapter with 4 x AA batteries: ~6-hr. runtime. These figures are for non-wireless monitors. Packs are plug-and-play and can be replaced on the go without tools.
    Is Man Down always on?
    No. Man Down is off by default, with a 30-second motionless time and 30-second warning time by default once enabled. It is disabled while the MultiRAE is connected to an AutoRAE 2, truck mount, or desktop cradle.
    How often does it need calibration?
    The MultiRAE must be calibrated if it does not pass a bump test, or at least once every 180 days, depending on use and sensor exposure to poisons and contaminants. Bump testing and calibration can be fully automatic with AutoRAE 2, or manual. Our Repair Depot handles calibration too.
    Is it rated for hazardous locations?
    Yes. CSA Class I, Division 1, Groups A, B, C and D, T4 and Class II, Division 1; Groups E, F, G; T85°C, plus ATEX II 1G Ex ia IIC T4 Ga and IECEx Ex ia IIC T4 Ga (Ex ia d IIC T4 Gb with IR Sensor installed). See the Certifications tab for the full list.
    Who handles service, calibration and repair?
    FarrWest is a Honeywell Authorized Service Provider for BW and RAE Systems gas detection. Instruments covered by a Honeywell Service Made Simple Enhanced agreement are repaired, calibrated and returned by our Repair Depot. Coverage depends on the model and agreement, so see Honeywell warranty service or call 210.566.1857 to confirm.
    Next step

    Build your MultiRAE for the job

    Tell us the gases you need to see and whether you want wireless. We will come back with a sensor configuration and a quote.

    CONTACT US