No products in the cart.

  • Teledyne FLIR · Radionuclide identification

    FLIR identiFINDERR440

    Highly Sensitive, Sourceless Handheld RID

    The identiFINDER R440 is a lightweight, sourceless radionuclide identification device (RID) that delivers sensitive detection and fast results for routine survey or secondary screening response missions. A bold, easy-to-read interface, an IP67-rated enclosure and hot swappable batteries keep it working through extended operations.

    ≤3.2 lbs(≤1.5 kg)
    IP67Rated enclosure
    4Detector options
    <2 minsFrom cold start
    Two FLIR identiFINDER R440 handhelds: one screen shows a dose rate of 981 µrem/h, the other an Identify Result reading Cesium-137
    Dose-rate and Identify Result screens
    From reading to result

    Survey, find, identify, report back

    Teledyne FLIR built the R440 for routine survey and secondary screening. Operator training is under 10 minutes, and every step below uses the same handheld, from the first dose-rate reading to sending the result off the scene.

    01 Survey

    Read the dose rate

    Power on and work the scene. Dose rate is measured from 10nSv/h to 10mSv/h with every detector option, and a high dose rate range continues to 500mSv/h.

    Dose rate range (Cs-137, all)
    10nSv/h - 10mSv/h (1µrem/h - 1rem/h) / ±10 %
    Cold start
    <2 mins from cold start.
    02 Find

    360° EasyFinder™

    The bold, easy-to-read interface with 360° EasyFinder™ mode expedites decision-making to keep personnel and the community safe.

    Display
    Transflective color LCD / 3” (2.72” x 1.61”) Color TFT Display, Resolution: 800 x 480 pixels
    03 Identify

    Name the nuclide

    Switch to ID mode. Sourceless stabilization improves data collection, reducing false positives.

    identiFINDER R440 Identify Result screen showing Cesium-137 with its library category
    Identify Result screen
    Nuclide identification
    Exceeds ANSI N42.34
    Library categories
    SNM, IND, MED, NORM
    04 Report

    Send it back

    Remote viewing operation, GPS, and reach-back over Bluetooth/WiFi via available app (iOS/Android) or over USB via intuitive Web Interface.

    Data format
    Universal API and ANSI N42.42
    GPS
    72-channel u-blox M8 engine

    Dose-rate coverage by mode

    Cs-137 · all detectors · log scale
    ID mode
    10nSv/h - 250µSv/h
    Dose rate range
    10nSv/h - 10mSv/h
    High dose rate range
    10mSv/h - 500mSv/h

    In US units: ID mode 1µrem/h - 25mrem/h, dose rate range 1µrem/h - 1rem/h, high dose rate range 1rem/h - 50rem/h. Bars drawn to a logarithmic scale for comparison.

    Detector options

    Four crystals, one handheld

    The R440 is available with NaI, NaIL, CLLBC and LaBr detector options. They trade gamma sensitivity against resolution and differ in how they handle neutrons. Every option covers 10 keV to 10 MeV with a 1024-channel gamma spectrum.

    Gamma + neutron indication

    NaI(Tl)

    2.0 x 2.0 in (51 x 51 mm)

    ≤7% 662 keV
    Typical resolution
    ≤7% FWHM at 662 keVwith NaI and NaIL detector at 20 °C
    Gamma sensitivity (Cs-137)
    1850 cps/μSv/h
    Neutron
    Neutron indicationvia the extended energy range in the NaI (G) version; neutron sensitivity not applicable to NaI
    Optional · gamma + neutron measurement

    NaIL

    2.0 x 2.0 in (51 x 51 mm)

    ≤7% 662 keV
    Typical resolution
    ≤7% FWHM at 662 keVwith NaI and NaIL detector at 20 °C
    Gamma sensitivity (Cs-137)
    1850 cps/μSv/h
    Neutron sensitivity
    ≥2.8 cps/nv
    Gamma + neutron measurement

    CLLBC

    1.4 x 1.5 in (36 x 38 mm)

    ≤4.5% 662 keV
    Typical resolution
    ≤4.5% FWHM at 662 keVwith CLLBC detector at 20 °C
    Gamma sensitivity (Cs-137)
    985 cps/μSv/h
    Neutron sensitivity
    17 cps/nv
    Optional · gamma, with optional ZnS(Li) panels for neutrons

    LaBr

    1.5 x 1.5 in (38 x 38 mm)

    ≤3% 662 keV
    Typical resolution
    ≤3% FWHM at 662 keVwith LaBr detector at 20 °C
    Gamma sensitivity (Cs-137)
    780 cps/μSv/h
    Neutron sensitivity
    7.8 cps/nv
    Optional neutron panels

    Neutron – ZnS(Li) (optional): 2ea. Moderated Panels (27 x 58 x 5 mm)

    Spectrum

    10 keV to 10 MeV (All detectors) · 1024 channels

    Stabilization

    Sourceless “Quantum gain” stabilization (patents pending)

    “Detector options offer higher sensitivity and better resolution than comparatively sized RIDs.”Teledyne FLIR

    Illustration: the peaks above are schematic, not measured spectra. Tell us what you screen for and request a quote to talk through configuration.

    Ability to power through missions

    Swap the pack, keep the reading

    Hot swappable batteries facilitate continuous operation on extended missions. An internal battery carries the instrument while the main pack is out, so the unit stays in operation with no data loss.

    Li-Ion smartpack
    1xsupplied
    Hot swap
    > 10 mins
    Li-Ion smartpack
    1xsupplied
    Hot swap
    > 10 mins
    4x AA pack
    1xsupplied

    Supplied: 2x rechargeable Li-Ion smartpacks and 1x 4x AA pack. Internal battery allows > 10 mins operation with battery pack removed to allow ‘hot swapping’ of main battery packs.

    Charge outside the instrument

    Batteries charge outside the instrument while the instrument is on standby, for instant readiness in the response vehicle.

    Plugged in and on

    The power management system lets the unit be plugged in and on while charging batteries, ready to go at a moment's notice.

    Recharge time

    Recharge time ≤4h when using AC; recharge >4h when using USB. Input 100-240V AC (wall adapter and USB cable supplied).

    Situational awareness when you need it

    Get the result off the scene

    When threat detection occurs, getting results communicated as quickly as possible is critical. The R440 gives three routes out: wireless to a phone app, USB to a browser, and a standard data format that user-deployed networks can take in.

    identiFINDER R440 handheld, the source of the data sent for reach-back
    • GPS · 72-channel u-blox M8 engine
    • Storage · 32GB internal memory
    • Software · On-board web server software
    Reach-back networks

    Universal API and ANSI N42.42 data format enables reach-back with user deployed networks such as:

    • Mobile Field Kit
    • ATAC
    • Sigma Edge
    • Safe Environment Gateway
    • and others

    Communication: USB 2.0, USB OTG; Bluetooth® Class BLE 4.0 and 2.1 with EDR ≤30m range, WiFi 802.11 g/n (can be disabled at manufacture).

    Higher performance in a rugged form factor

    One hand, long shifts

    Its light weight makes single-handed operation easy during extended operations, while the IP67-rated enclosure is built to survive.

    Firefighter in turnout gear holding the identiFINDER R440 at arm's length outdoors
    Fire service
    Operator surveying a shipping container marked with a radiation warning sign using the identiFINDER R440
    Container survey
    Police officer holding the identiFINDER R440 near a vehicle, seen from behind
    Law enforcement

    Teledyne FLIR adds that “improved shock protection and a locking battery cap provides additional ruggedness.” The housing is aluminum.

    Weight
    ≤3.2 lbs (≤1.5 kg)
    Dimensions
    ≤ 4 x 10.6 x 3.7 in (10.2 x 26.9 x 9.4 cm) W x L x H
    Enclosure
    Aluminum housing; protection rating IP67 according to IEC 60529
    Operating
    -4 to 122 °F (-20 to 50 °C) · humidity 0 to 100%
    Training
    <10 mins for operator; 1 day for advanced user
    Specifications

    Key specifications

    Download the datasheet below for the full document.

    TechnologyRadionuclide Identification Device (RID)
    Detectors
    Gamma with Neutron Indication – NaI(Tl)2.0 x 2.0 in (51 x 51 mm)
    Gamma with Neutron Measurement – NaIL (optional)2.0 x 2.0 in (51 x 51 mm)
    Gamma with Neutron Measurement – CLLBC1.4 x 1.5 in (36 x 38 mm)
    Gamma – LaBr (optional)1.5 x 1.5 in (38 x 38 mm)
    Neutron – ZnS(Li) (optional)2ea. Moderated Panels (27 x 58 x 5 mm)
    Performance
    Energy range (gamma)10 keV to 10 MeV (All detectors)
    Gamma sensitivity (Cs-137)
    • 1850 cps/μSv/h – (NaI/NaIL)
    • 985 cps/μSv/h – (CLLBC)
    • 780 cps/μSv/h – (LaBr)
    Neutron sensitivity
    • ≥2.8 cps/nv – (NaIL – not applicable to NaI)
    • 17 cps/nv – (CLLBC)
    • 7.8 cps/nv – (LaBr)
    Gamma spectrum length1024 channels
    Typical resolution
    • ≤7% FWHM at 662 keV with NaI and NaIL detector at 20 °C
    • ≤4.5% FWHM at 662 keV with CLLBC detector at 20 °C
    • ≤3% FWHM at 662 keV with LaBr detector at 20 °C
    StabilizationSourceless “Quantum gain” stabilization (patents pending)
    LinearizationReal-time linearization of gamma energy
    Identification
    ThreatsDetects gamma and/or neutron radiation emitted from natural occurrences in the environment, special nuclear material, industrial, or medical material
    Nuclide identificationExceeds ANSI N42.34
    Library categoriesSNM, IND, MED, NORM
    Dose rate range (Cs-137, all)10nSv/h - 10mSv/h (1µrem/h - 1rem/h) / ±10 %
    Dose rate range ID mode (Cs-137, all)10nSv/h - 250µSv/h (1µrem/h - 25mrem/h)
    High dose rate range (Cs-137, all)10mSv/h - 500mSv/h (1rem/h - 50rem/h)
    Display & alertsTransflective color LCD / 3” (2.72” x 1.61”) Color TFT Display, Resolution: 800 x 480 pixels
    CommunicationUSB 2.0, USB OTG; Bluetooth® Class BLE 4.0 and 2.1 with EDR ≤30m range, WiFi 802.11 g/n (can be disabled at manufacture)
    Data storage32GB internal memory
    GPS72-channel u-blox M8 engine
    SoftwareOn-board web server software
    Training requirements<10 mins for operator; 1 day for advanced user
    Input voltage100-240V AC (wall adapter and USB cable supplied)
    Battery specs
    • Supplied: 2x rechargeable Li-Ion smartpacks and 1x 4x AA pack
    • Recharge time ≤4h when using AC; recharge >4h when using USB.
    Hot swap featureInternal battery allows > 10 mins operation with battery pack removed to allow ‘hot swapping’ of main battery packs. Unit remains in operation with no data loss.
    Cold start time<2 mins from cold start.
    Environmental
    Operating temp (ambient)-4 to 122 °F (-20 to 50 °C)
    Operating humidity0 to 100%
    Storage temp-4 to 122 °F (-20 to 50 °C)
    Physical
    Dimensions (W x L x H)≤ 4 x 10.6 x 3.7 in (10.2 x 26.9 x 9.4 cm)
    Weight≤3.2 lbs (≤1.5 kg)
    Enclosure & protectionAluminum housing; protection rating IP67 according to IEC 60529

    This product is subject to United States export regulations and may require US authorization prior to export, reexport, or transfer to non-US persons or parties.

    FAQ

    Common questions

    Which detector options does the identiFINDER R440 offer?
    Detectors are NaI(Tl) and CLLBC, plus optional NaIL and LaBr, and optional ZnS(Li) neutron panels. Typical resolution at 662 keV is ≤7% FWHM with NaI and NaIL, ≤4.5% with CLLBC and ≤3% with LaBr (at 20 °C). Request a quote to discuss configuration.
    Does the R440 detect neutrons?
    It depends on the detector. The extended energy range provides neutron indication in the NaI (G) version. The NaIL and CLLBC detectors are listed as gamma with neutron measurement, with neutron sensitivity of ≥2.8 cps/nv (NaIL) and 17 cps/nv (CLLBC). LaBr is 7.8 cps/nv, and optional ZnS(Li) moderated panels are listed as a separate neutron detector.
    Can I change the batteries mid-mission?
    The R440 is supplied with 2x rechargeable Li-Ion smartpacks and 1x 4x AA pack. An internal battery allows > 10 mins operation with the battery pack removed, so you can hot swap and the unit remains in operation with no data loss.
    Does it need a radioactive check source for stabilization?
    The R440 uses sourceless “Quantum gain” stabilization (patents pending). Teledyne FLIR says sourceless stabilization improves data collection, reducing false positives.
    How do results get back to command?
    Remote viewing operation, GPS, and reach-back over Bluetooth/WiFi via an available app (iOS/Android), or over USB via the web interface. Universal API and ANSI N42.42 data format enable reach-back with user deployed networks such as Mobile Field Kit, ATAC, Sigma Edge and Safe Environment Gateway. WiFi can be disabled at manufacture.
    How much training does an operator need?
    Training takes <10 mins for an operator and 1 day for an advanced user.
    What is the R440's ingress rating?
    The aluminum housing carries a protection rating of IP67 according to IEC 60529.
    Can the R440 be exported?
    This product is subject to United States export regulations and may require US authorization prior to export, reexport, or transfer to non-US persons or parties. Ask us before ordering for use outside the US.
    Next step

    Sourceless identification, in one hand

    Tell us what you screen for, which detector you are considering and how your team reports results, and talk through the identiFINDER R440 with FarrWest.

    CONTACT US