The MUVE R430 is a radiation detector designed for unmanned aerial systems (UAS), used to detect, locate, measure, map, and identify radioactive sources from above. It flies on the Teledyne FLIR SkyRanger R70 and is integrated into the R70’s Mission Control Software, with visible and audible alerts that expedite response measures.
101.6 x 101.6 x 101.6 mm payload
Teledyne FLIR puts it plainly: time, distance, and shielding are key in radiation safety. The MUVE R430 can perform an initial assessment or create a contamination map while it is operated from a safe distance.
When dangerous conditions exist, or are anticipated, the R430 flies in for that initial assessment, reaching hard-to-reach places and environments while the operator stays back. It uses the same, familiar interface as the identiFINDER instruments.
Teledyne FLIR describes the R430’s job in five verbs. Here is how an aerial survey comes together.
A NaI(Tl) cubic detector read by a silicon photomultiplier picks up gamma radiation emitted from natural occurrences in the environment, special nuclear material, industrial, or medical material.
Quick deployment allows for rapid threat assessment even in areas where contamination would be difficult to access normally, while the operator stays at a safe distance.
Dose rate is measured across a wide span, and an energy compensated Geiger Müller tube serves as the high dose rate gamma detector.
The R430 can create a contamination map. It provides the Mission Control Software the data needed to give a complete view of the scene.
The same detection and spectroscopic algorithms as the other identiFINDER instruments, with nuclide identification according to ANSI N42.42.
The 101.6 x 101.6 x 101.6 mm payload pairs a spectroscopic NaI(Tl) detector with a Geiger Müller tube for high dose rates. On the Gamma/Neutron model, two moderated ZnS panels add neutron detection.
A cubic detector with silicon photomultiplier (SiPM), sourceless gain stabilisation and real time linearisation of gamma energy.
An energy compensated Geiger Müller (GM) tube serves as the payload’s high dose rate gamma detector, alongside the NaI(Tl) spectroscopic detector.
Fitted to the Gamma/Neutron model only: two moderated ZnS panels for detection of neutron emissions.
Illustration: bars are drawn on a logarithmic scale.
The R430 is integrated into the SkyRanger R70’s Mission Control Software (MCS). Readings arrive as visible and audible alerts that expedite response measures, while the operator works from a safe distance.
Detects, measures and identifies from above, with 8GB internal memory and on-board webserver software.
Communication over USB-C and a UAS interface port.
The R430 provides the Mission Control Software the data needed to give a complete view of the scene.
Alerts that expedite response measures, with the operator kept at a safe distance.
The SkyRanger® R70 is the airframe for the R430. See the R70 on FarrWest.
Ask us about airframe compatibility for your fleet. View SkyRanger R70The R430 uses the same detection and spectroscopic algorithms as the other identiFINDER instruments, providing detection and identification of radioactive sources you can trust (Teledyne FLIR).
“The MUVE™ R430 brings the pedigree of the identiFINDER series of best-selling radionuclide identification devices to the sky.”
Teledyne FLIR
Teams already running identiFINDER handhelds or backpacks get the same, familiar interface from the air. Teledyne FLIR names three of them alongside the R430.
| Technology | |
|---|---|
| Technology | Radionuclide identification device (RID); Gamma and Gamma/Neutron models |
| Detectors | |
| Gamma Detector – NaI(Tl) | 1.77 x 1.77 x 1.77 in (45 x 45 x 45 mm) cubic detector with silicon photomultiplier (SiPM) |
| High Dose Rate Gamma Detector | Energy Compensated Geiger Müller (GM) Tube |
| Neutron Detector – ZnS (GN Model only) | 27 x 58 x 5 mm moderated panels (2 each) |
| Performance | |
| Energy Range (Gamma) | 20 keV - 3 MeV |
| Gamma Sensitivity (Cs-137) | 1610 cps/µSv/h |
| Gamma Spectrum Length | 1024 channels |
| Typical Resolution | ≤ 7% FWHM at 662 keV (20 °C) |
| Stabilisation | Sourceless gain stabilisation |
| Linearisation | Real time linearisation of gamma energy |
| Dose rate (Cs-137) | |
|---|---|
| Dose Rate Range (Cs-137) | 10 µrem/h – 1 rem/h ± 10%, 100 nSv/h – 10 mSv/h ± 10% |
| Dose Rate Range ID Mode (Cs-137) | 0.1 µrem/h – 5mrem/h, 1 nSv/h – 50 µSv/h |
| Overload Dose Rate Range | 1 – 100 rem/h, 10 mSv/h – 1 Sv/h |
| Identification | |
|---|---|
| Sample Introduction | Absorption of EM gamma and neutron emissions |
| Threats | Detects neutron and gamma radiation emitted from natural occurrences in the environment, special nuclear material, industrial, or medical material |
| Nuclide Identification | According to ANSI N42.42 |
| Library Categories | SNM, IND, MED, NORM |
| Time to Identification | From a few seconds to a few minutes |
| Data | |
| Communication | USB-C, UAS interface port |
| Data Storage | 8GB internal memory |
| Software | On-board webserver software |
| Data File Format | According to ANSI N42.42 |
| Physical | |
|---|---|
| Dimensions (L x W x H) | 4 x 4 x 4 in (101.6 x 101.6 x 101.6 mm) |
| Weight | ≤ 2.0lbs (≤ 0.9 kg) |
| Enclosure and Protection | Injection moulded housing with overmould; rating IP67 according to IEC 60529 ; MIL STD 810G (Salt/Fog) compliant |
| Airframe | SkyRanger® R70 |
| Environment | |
| Operating Temperature | -22 to 140 °F (-30 to 60 °C) |
| Operating Humidity | 10 to 93%, non-condensing |
| Storage Temperature | 14 to 95 °F (-10 to 35 °C) |
| Service | |
| Service Interval | 5-year factory maintenance |
Neutron values apply to the Gamma/Neutron model.
Download the official Teledyne FLIR MUVE R430 datasheet, or ask us for product information.
The official Teledyne FLIR Defense datasheet for your evaluation or procurement file.
PDF · Teledyne FLIR Talk to usTell us about the area you need to survey, your airframe, and whether you need the Gamma or Gamma/Neutron model.
Request a quote AirframeThe Teledyne FLIR airframe for the R430.
View product AirframeThe second Teledyne FLIR airframe named for the R430.
View product ServiceOEM-certified service and support on every product we deliver. When a repair or calibration falls outside our in-house scope, we coordinate directly with the manufacturer and manage the logistics end to end.
Learn moreFarrWest is a pre-approved vendor on BuyBoard and Purchasing Cooperative of America (PCA). Government agencies can buy on competitively-bid cooperative contracts, with no lengthy RFP.
How co-op buying worksServiceOEM-certified service and support on every product we deliver: functional checks and certified calibration on the manufacturer’s required cycle, back in service in 48–72 hours typical.
Repair DepotSince 2004Serving Hazmat, Fire, Police, EMS, and Specialty Vehicle operations nationwide since 2004, with expert support, training, and service after the sale.
About FarrWestFLIR Fido X4 handheld explosives trace detector uses TrueTrace five-channel sensing to alarm in 10-25 seconds, with up to 16 h on…
View productRelatedFLIR Griffin G510 person-portable GC-MS confirms chemical hazards in liquids, solids and vapors in the field, with a heated sample probe. Request…
View productRelatedFLIR Griffin G510x portable GC-MS is optimized for narcotics and explosives: it IDs street-drug constituents in under 5 minutes with onboard SWGDRUG…
View productFarrWest quotes the MUVE R430 on request. Tell us the area you need to cover, the airframe you fly, and whether you need the Gamma or Gamma/Neutron model.