DrägerSensor XXS Cl2 is a replaceable electrochemical chlorine sensor for monitoring hazardous gases in food, chemical, pulp and paper, power generation, and water treatment facilities.
DrägerSensor XXS Cl2 is a replaceable electrochemical sensor designed for monitoring hazardous gas concentrations in ambient air. Compatible with Dräger Pac 8000, X-am 5000, and X-am 8000 gas detection devices. Features excellent linearity, fast response times (≤30 seconds), and broad measurement range. Suitable for food and beverage, chemical manufacturing, pulp and paper, power generation, sewage treatment, and water treatment applications. Expected sensor life exceeds 2 years with 1-year warranty.
| Performance | |
| Detection limit | 0.05 ppm |
| Resolution | 0.05 ppm |
| Measurement range (Cl2) | 0 to 20 ppm |
| Measurement range (F2) | 0 to 20 ppm |
| Measurement range (Br2) | 0 to 20 ppm |
| Measurement range (ClO2) | 0 to 20 ppm |
| Relative sensitivity (Cl2) | 1.00 |
| Relative sensitivity (F2) | 1.00 |
| Relative sensitivity (Br2) | 1.00 |
| Relative sensitivity (ClO2) | 0.60 |
| Response time | ≤30 s (t90) |
| Sensitivity | ≤±2% of measured value |
| Sensitivity drift | ≤±2% of measured value/month |
| Operating pressure | (700 to 1,300) hPa |
| Temperature influence - Sensitivity | ≤±5% of measured value |
| Humidity influence - Sensitivity | ≤±0.4% of measured value/%RH |
| Test gas | approx. 1 to 18 ppm Cl2 |
| Expected sensor life | >2 years |
| Other | |
| Order no. | 6810890 |
| Zero point drift (20°C) | ≤±0.2 ppm/year |
| Warm-up time | ≤30 min |
| Operating temperature | (-40 to 50)°C |
| Operating humidity | (10 to 90)% RH |
| Temperature influence - Zero point | ≤±0.05 ppm |
| Humidity influence - Zero point | No effect |
| Guaranty | 1 year |
| Plug&Play | no |
| Replaceable | yes |
Calibration, repair and maintenance for your detection instruments.