No products in the cart.

  • Teledyne FLIR · UAS radiation payload

    FLIR MUVE R430

    Radionuclide Identification Device for Unmanned Aerial Systems

    The MUVE R430 is a radiation detector designed for unmanned aerial systems (UAS), used to detect, locate, measure, map, and identify radioactive sources from above. It flies on the Teledyne FLIR SkyRanger R70 and is integrated into the R70’s Mission Control Software, with visible and audible alerts that expedite response measures.

    Quote on request · FarrWest
    45 x 45 x 45 mmNaI(Tl) cubic detector
    20 keV - 3 MeVGamma energy range
    1024Gamma spectrum channels
    IP67According to IEC 60529
    FLIR MUVE R430 radiation detection payload, a black cube-shaped module with a USB-C port on its front plate and a carrying handle on top 101.6 x 101.6 x 101.6 mm payload
    Quadcopter in flight against a blue sky with a black MUVE payload module mounted beneath the airframe
    Time. Distance.
    Shielding.

    Teledyne FLIR puts it plainly: time, distance, and shielding are key in radiation safety. The MUVE R430 can perform an initial assessment or create a contamination map while it is operated from a safe distance.

    When dangerous conditions exist, or are anticipated, the R430 flies in for that initial assessment, reaching hard-to-reach places and environments while the operator stays back. It uses the same, familiar interface as the identiFINDER instruments.

    Evaluate radioactive threats from a safe distance · Reduce reaction times
    Fly the area

    Detect, locate, measure, map, identify

    Teledyne FLIR describes the R430’s job in five verbs. Here is how an aerial survey comes together.

    Survey area Source Operator · safe distance 1 2 3 4 5
    Illustration
    01

    Detect

    A NaI(Tl) cubic detector read by a silicon photomultiplier picks up gamma radiation emitted from natural occurrences in the environment, special nuclear material, industrial, or medical material.

    45 x 45 x 45 mm NaI(Tl)
    1610 cps/µSv/h (Cs-137)
    02

    Locate

    Quick deployment allows for rapid threat assessment even in areas where contamination would be difficult to access normally, while the operator stays at a safe distance.

    Ready to deploy in minutes
    03

    Measure

    Dose rate is measured across a wide span, and an energy compensated Geiger Müller tube serves as the high dose rate gamma detector.

    100 nSv/h – 10 mSv/h ± 10%
    Overload 10 mSv/h – 1 Sv/h
    04

    Map

    The R430 can create a contamination map. It provides the Mission Control Software the data needed to give a complete view of the scene.

    Visible and audible alerts
    in Mission Control Software
    05

    Identify

    The same detection and spectroscopic algorithms as the other identiFINDER instruments, with nuclide identification according to ANSI N42.42.

    From a few seconds to a few minutes
    Library: SNM, IND, MED, NORM
    Inside the payload

    Gamma, high-dose-rate and (on GN) neutron detection

    The 101.6 x 101.6 x 101.6 mm payload pairs a spectroscopic NaI(Tl) detector with a Geiger Müller tube for high dose rates. On the Gamma/Neutron model, two moderated ZnS panels add neutron detection.

    Spectroscopy

    NaI(Tl) gamma detector

    A cubic detector with silicon photomultiplier (SiPM), sourceless gain stabilisation and real time linearisation of gamma energy.

    45 x 45 x 45 mm cubic detector
    ≤ 7% FWHM at 662 keV (20 °C)
    1024 channels
    High dose rate

    Geiger Müller tube

    An energy compensated Geiger Müller (GM) tube serves as the payload’s high dose rate gamma detector, alongside the NaI(Tl) spectroscopic detector.

    High Dose Rate Gamma Detector
    Energy Compensated Geiger Müller (GM) Tube
    GN model only

    ZnS neutron panels

    Fitted to the Gamma/Neutron model only: two moderated ZnS panels for detection of neutron emissions.

    27 x 58 x 5 mm moderated panels (2 each)

    Dose-rate coverage

    Cs-137 · log scale
    ID modeDose Rate Range ID Mode
    0.1 µrem/h – 5mrem/h, 1 nSv/h – 50 µSv/h
    Dose rateDose Rate Range
    10 µrem/h – 1 rem/h ± 10%, 100 nSv/h – 10 mSv/h ± 10%
    OverloadOverload Dose Rate Range
    1 – 100 rem/h, 10 mSv/h – 1 Sv/h
    nSv/hµSv/hmSv/hSv/h

    Illustration: bars are drawn on a logarithmic scale.

    Model

    Gamma

    • NaI(Tl) 45 x 45 x 45 mm cubic detector with SiPM
    • Energy Compensated Geiger Müller (GM) Tube
    • Energy range 20 keV - 3 MeV
    Model

    Gamma/Neutron

    • Everything in the Gamma model
    • ZnS neutron detector, 27 x 58 x 5 mm moderated panels (2 each)
    The R430 is a radionuclide identification device (RID) in Gamma and Gamma/Neutron models. Tell us which configuration your mission needs when you request a quote.
    Fully integrated situational awareness

    From the payload to the operator

    The R430 is integrated into the SkyRanger R70’s Mission Control Software (MCS). Readings arrive as visible and audible alerts that expedite response measures, while the operator works from a safe distance.

    Payload

    MUVE R430

    Detects, measures and identifies from above, with 8GB internal memory and on-board webserver software.

    Interface

    UAS interface port

    Communication over USB-C and a UAS interface port.

    Airframe

    SkyRanger R70 MCS

    The R430 provides the Mission Control Software the data needed to give a complete view of the scene.

    Operator

    Visible & audible alerts

    Alerts that expedite response measures, with the operator kept at a safe distance.

    Data on board

    Communication
    USB-C, UAS interface port
    Data storage
    8GB internal memory
    Software
    On-board webserver software
    Data file format
    According to ANSI N42.42
    Nuclide ID
    According to ANSI N42.42
    Airframe

    Teledyne FLIR SkyRanger R70

    The SkyRanger® R70 is the airframe for the R430. See the R70 on FarrWest.

    Ask us about airframe compatibility for your fleet. View SkyRanger R70
    Tried and trusted

    identiFINDER, in the sky

    The R430 uses the same detection and spectroscopic algorithms as the other identiFINDER instruments, providing detection and identification of radioactive sources you can trust (Teledyne FLIR).

    “The MUVE™ R430 brings the pedigree of the identiFINDER series of best-selling radionuclide identification devices to the sky.”

    Teledyne FLIR

    Teams already running identiFINDER handhelds or backpacks get the same, familiar interface from the air. Teledyne FLIR names three of them alongside the R430.

    Applications (Teledyne FLIR)
    • Radionuclide Threat Monitoring
    • Homeland Security
    • Defense
    • Nuclear Power Plants
    • Mining
    • Emergency response
    • Environmental monitoring
    • Surveying
    Specifications

    MUVE R430 specs

    Technology
    TechnologyRadionuclide identification device (RID); Gamma and Gamma/Neutron models
    Detectors
    Gamma Detector – NaI(Tl)1.77 x 1.77 x 1.77 in (45 x 45 x 45 mm) cubic detector with silicon photomultiplier (SiPM)
    High Dose Rate Gamma DetectorEnergy Compensated Geiger Müller (GM) Tube
    Neutron Detector – ZnS (GN Model only)27 x 58 x 5 mm moderated panels (2 each)
    Performance
    Energy Range (Gamma)20 keV - 3 MeV
    Gamma Sensitivity (Cs-137)1610 cps/µSv/h
    Gamma Spectrum Length1024 channels
    Typical Resolution≤ 7% FWHM at 662 keV (20 °C)
    StabilisationSourceless gain stabilisation
    LinearisationReal time linearisation of gamma energy
    Dose rate (Cs-137)
    Dose Rate Range (Cs-137)10 µrem/h – 1 rem/h ± 10%, 100 nSv/h – 10 mSv/h ± 10%
    Dose Rate Range ID Mode (Cs-137)0.1 µrem/h – 5mrem/h, 1 nSv/h – 50 µSv/h
    Overload Dose Rate Range1 – 100 rem/h, 10 mSv/h – 1 Sv/h
    Identification
    Sample IntroductionAbsorption of EM gamma and neutron emissions
    ThreatsDetects neutron and gamma radiation emitted from natural occurrences in the environment, special nuclear material, industrial, or medical material
    Nuclide IdentificationAccording to ANSI N42.42
    Library CategoriesSNM, IND, MED, NORM
    Time to IdentificationFrom a few seconds to a few minutes
    Data
    CommunicationUSB-C, UAS interface port
    Data Storage8GB internal memory
    SoftwareOn-board webserver software
    Data File FormatAccording to ANSI N42.42
    Physical
    Dimensions (L x W x H)4 x 4 x 4 in (101.6 x 101.6 x 101.6 mm)
    Weight≤ 2.0lbs (≤ 0.9 kg)
    Enclosure and ProtectionInjection moulded housing with overmould; rating IP67 according to IEC 60529 ; MIL STD 810G (Salt/Fog) compliant
    AirframeSkyRanger® R70
    Environment
    Operating Temperature-22 to 140 °F (-30 to 60 °C)
    Operating Humidity10 to 93%, non-condensing
    Storage Temperature14 to 95 °F (-10 to 35 °C)
    Service
    Service Interval5-year factory maintenance

    Neutron values apply to the Gamma/Neutron model.

    FAQ

    Common questions

    Which drone does the MUVE R430 fly on?
    The R430 flies on the SkyRanger® R70. Ask us about compatibility with your fleet.
    Does the R430 detect neutrons?
    It depends on the model. The R430 comes in Gamma and Gamma/Neutron models; the ZnS neutron detector (27 x 58 x 5 mm moderated panels, 2 each) is fitted to the GN model only. Tell us which model you need when you request a quote.
    How quickly does it identify a source?
    Time to identification is from a few seconds to a few minutes. Nuclide identification is according to ANSI N42.42, with library categories SNM, IND, MED, NORM.
    How does the operator see the readings?
    The R430 is integrated into the SkyRanger R70’s Mission Control Software (MCS), providing visible and audible alerts that expedite response measures. On the payload itself: USB-C and a UAS interface port, 8GB internal memory, on-board webserver software and data files according to ANSI N42.42.
    How rugged is the payload?
    It has an injection moulded housing with overmould, rated IP67 according to IEC 60529 and MIL STD 810G (Salt/Fog) compliant. Operating temperature is -22 to 140 °F (-30 to 60 °C) and operating humidity 10 to 93%, non-condensing.
    What maintenance does it need?
    The service interval is 5-year factory maintenance. Teledyne FLIR has also published software firmware update 430.23.1.86 for all MUVE R430 customers. For service questions, see the FarrWest Repair Depot.
    How much does it weigh?
    The weight is ≤ 2.0lbs (≤ 0.9 kg). Size is 4 x 4 x 4 in (101.6 x 101.6 x 101.6 mm).
    Are there export controls?
    Teledyne FLIR notes that its products may be subject to US export regulations depending upon specifications for the final product, and that jurisdiction and classification will be provided upon request.
    Next step

    Survey from above, from a safe distance

    FarrWest quotes the MUVE R430 on request. Tell us the area you need to cover, the airframe you fly, and whether you need the Gamma or Gamma/Neutron model.

    CONTACT US