The Mirion Technologies DMC 3000 Neutron Module is an add-on dosimeter for military personnel, first responders, and radiation workers requiring operational neutron dosimetry measurement.
The Neutron Module provides operational dosimetry for Military, First Responders and radiation workers where there is a Neutron radiation risk. The add-on Neutron Module attaches to the DMC 3000 dosimeter and is able to measure Hp(10) radiation at a wide range of energy levels. Features include dose and dose rate Neutron Hp(10) display, totalized dose for Hp(10) Gamma + Neutron, superior gamma rejection, full Neutron energy range coverage, meets IEC and ANSI standards, waterproof IP67 rating, and operates over 2400 hours continuously without requiring supplementary battery.
| Performance | |
| Neutron energy range | 0.025 eV to 15 MeV |
| Effective Range of Dose | 2 µSv to 100 Sv (0.2 mrem to 10000 rem) |
| Display Resolution (Dose) | 0,1 μSv to 10 Sv (0.01 mrem to 1000 rem) up to four decimal places |
| Effective Range of Dose Rate | 1 µSv/h to 10Sv/h (0.1 mrem/h to 1000 rem/h) |
| Display Resolution (Dose Rate) | 100 µSv/h to 10 Sv/h (10 mrem/h to 1000 rem/h) up to three decimal places |
| Accuracy Hp(0,07) Neutron | ≤ ± 10% (AmBe, 0.75 mSv/h, 75 mrem/h, target 1,3) |
| Temperature range | -10°C to 50°C (14°F to 122°F) |
| Power | |
| 10 calendar month battery life | 8 h per day, 5 days per week in run mode, without excessive alarms |
| 2400 h battery life | DMC 3000 with Neutron module and DMC 3000 in continuous run, without excessive alarms |
| Physical | |
| Dimensions with DMC 3000 (without clip) | 131 x 60 x 21 mm (5.1 x 2.4 x 0.8 in) max. |
| Dimensions with DMC 3000 (with standard clip) | 131 x 60 x 28mm (5.1 x 2.4 x 1.1 in) |
| Weight with DMC 3000 | < 138 g (4.9 oz) |
| Approvals & Warranty | |
| IP67 protection | 1 m (39 in) during 1 h |
| Other | |
| Overload Indication (Dose) | from 10 Sv to >50 Sv (1000 rem to >5000 rem) |
| Overload Indication (Dose Rate) | from 10 Sv/h to >50 Sv/h (1000 rem/h to >5000 rem/h) |
| Hp(10) Dose Rate Linearity | < ± 20% up to 10 Sv/h, 1000 rem/h |
| Storage | -20°C to 71°C (-4°F to 160°F) |