    RKI Instruments

    GP-03

    Part # 72-0037-05

    The RKI Instruments GP-03 is a pocket-sized single-gas monitor designed to protect workers from combustible hydrocarbon exposure in hazardous atmospheres.

    or
    Add to Quote
    Questions? Talk to a specialist210.566.1857 · sales@farrwest.com

    Overview

    The GP-03 is a personal single gas monitor designed for protection from exposure to combustible hydrocarbons. It operates for 35 hours on alkaline batteries and 30 hours on rechargeable Ni-MH. The compact pocket-sized detector (2.1″W x 2.6″H x 0.9″D, 2.8 oz) features adjustable dual alarms, visual/audible/vibration alerts, data logging (5-300 hours), peak hold, STEL & TWA functions, and automatic backlight. Impact, dust, and water resistant with IP-67 rating. Intrinsically safe certified by ATEX/IECEx and CSA for Class I, Division 1 hazardous atmospheres. Field-replaceable sensor with 2+ year life expectancy. Includes rubber protective boot, alligator clip, software, and wrist strap.

    • Operates 35 or 30 hrs on alkaline / Ni-MH
    • Pocket size 2.1"(W) x 2.6"(H) x 0.9"(D)
    • Light weight 2.8 ounces
    • Impact, dust, and water resistant (IP-67)
    • Replaceable rubber boot
    • Data log 5 to 300 hours with adjustable intervals

    Specifications

    Performance
    Gas DetectedCombustible gas
    Detection PrincipleCatalytic combustion
    Detection Range (Increments)0 – 100% LEL (1% LEL increments)
    Alarm Set Points1st 10% LEL, 2nd 50% LEL, Over 100% LEL
    Alarm TypesGas alarms: 1st and 2nd (user adjustable), OVER alarm, STEL and TWA; Trouble alarms: Sensor connection, low battery circuit failure, and calibration range error
    Alarm MethodsGas alarm: Flashing LED's, intermittent buzzer, flashing gas value, and vibration; Trouble alarm: Flashing LED's, intermittent buzzer, and display of error message; STEL & TWA alarms: Flashing LED's, intermittent buzzer, flashing gas value, and vibration
    Gas SamplingDiffusion
    Response TimeT90 in 30 s
    Accuracy (whichever is greater)± 5% of reading or ± 2%
    DisplayDigital LCD, gas name & concentration, auto backlighting during alarm, operation icon, battery icon