No products in the cart.

  • Proengin / Fixed chemical detection

    Proengin AP4C-F

    Marine & Critical Infrastructure Detection System

    The AP4C-F is a chemical detector for gas and aerosol that provides continuous 24/7 monitoring for land or naval assets. It can detect a broad range of conventional and unconventional threats, from chemical warfare agents and toxic industrial chemicals to homemade terrorist mixtures and nontraditional agents, with fully automatic alarm and sampling that requires no action from the operator.

    24/7Continuous monitoring
    28 daysH₂ autonomy on 1 water bottle
    Gas, aerosolsDetection
    RS485Connectivity
    AP4C-F · fixed detectorGas · Aerosol
    Proengin AP4C-F fixed chemical detector housing, three-quarter view showing the top sampling inlet and side module
    • SensingHydrogen Flame Spectrometry
    Where it stands watch
    Continuous 24/7 monitoring for land or naval assets.

    The AP4C-F is designed to withstand the harsh environment of naval operation. Proengin states it is not sensitive to humidity and salt spray, and that alarm and sampling are fully automatic, requiring no action from the operator.

    According to Proengin, it is a combat proven system which has been tested and is in use with several navies, first responder fireboats, as well as on buildings and key infrastructure worldwide.

    Illustrative photo of a warship at sea, representing naval platform applications
    ApplicationNaval platforms
    Illustrative aerial photo of a large civic building in a city, representing strategic site applications
    ApplicationStrategic sites
    Ideal for
    • Naval platforms
    • Strategic sites
    • Military shelters
    • Transportation hub
    • Mass transit

    Illustrative photos; they do not show the detector.

    Coverage

    From sampling point to control station

    A handheld goes where an operator carries it. The AP4C-F stays put: Proengin offers options from full system integration to a ready to mount kit, for land or naval assets, with the detector sampling continuously and reporting over RS485 to a third-party solution or Proengin software solution.

    Illustration: AP4C-F detectors on a ship and on a building, each linked over RS485 to a central control station NAVAL PLATFORM STRATEGIC SITE AP4C-F AP4C-F AP4C-F AP4C-F CONTROL STATION RS485 RS485
    Illustration only. Detector count and placement are examples.
    1. 01Sample

      External & airtight sampling

      Sampling runs on its own: fully automatic alarm and sampling requiring no action from the operator.

    2. 02Analyze

      Continuous & simultaneous detection

      Hydrogen Flame Spectrometry covers gas and aerosols, with detection results within seconds, according to Proengin.

    3. 03Alarm

      Alarms set to your requirement

      Alarms are set at the factory to the customer's needs. Mode: instant concentration or dose.

    4. 04Report

      Into your control system

      RS485 to a third-party solution or Proengin software solution, with a built in 32Mbit flash memory keeping around 530h of data logging.

    24/7 operation

    Makes its own hydrogen

    The AP4C-F senses by Hydrogen Flame Spectrometry, and its H₂ is produced through an embedded electrolyzer. Proengin rates that at 28 days H₂ autonomy on 1 water bottle.

    1. Input

      1 water bottle

      28 days H₂ autonomy on 1 water bottle.

    2. On board

      Embedded electrolyzer

      H₂ produced through embedded electrolyzer, inside the detector.

    3. Sensing

      Hydrogen flame spectrometry

      The sensing technology behind detection of CWA (including 4th generation), TIC / TIM, gas and aerosols.

    4. Response

      Quick start-up

      Proengin lists quick start-up and response time among its key features.

    93% HR
    Operating humidity
    (non condensing) @ 55°C (131°F)
    -39°C to +71°C
    Storage temperature
    -38°F to +160°F
    Rain · Salt · Ice
    Tested against heavy rain, salt, fog, ice & freeze
    Built for the field

    Rugged design for field use and to withstand harsh environments (dust, humidity, temperature), and designed to sustain marine application.

    Threat coverage

    No library. No filters.

    Proengin describes the AP4C-F as able to detect a broad range of conventional and unconventional threats. It works with no library and no filters, providing continuous & simultaneous detection of gas and aerosol threats.

    Threat 01

    Chemical warfare agents

    Threat 02

    Toxic industrial chemicals

    Threat 03

    Homemade terrorist mixtures

    Threat 04

    Nontraditional agents

    At a glance
    Detection
    CWA (including 4th generation), TIC / TIM, Gas, aerosols
    Mode
    Instant concentration or dose
    Sensing
    Hydrogen Flame Spectrometry
    Alarms
    Factory configuration based on customer needs
    LibraryFilters
    Integration

    Flexible & easy integration

    Proengin states that, based on the initial requirement, it offers various options of deliverable, from full system integration to a ready to mount kit. Options are available; tell FarrWest about your vessel or site when you request a quote.

    Wall-mount control panel with indicator lamps, speaker grille and bar-graph window,
    Control panel
    Rugged display unit showing an alarm banner and a graph,
    Display unit
    • RS485 output

      Connectivity is RS485 to a third-party solution or Proengin software solution.

    • Turnkey integration

      Proengin states it does offer turnkey CBRN integration solutions.

    • Warranty & maintenance

      Warranty is 1 year. Proengin notes that prepaid maintenance and extended warranty options are available upon initial acquisition.

    The AP4C line

    Fixed, handheld, or chem + bio

    The AP4C-F is not the handheld AP4C. It is a fixed, mounted system for 24/7 monitoring. Proengin also offers a handheld for dismounted personnel, and the AP4C-FB adds biological detection in the same housing family.

    Specifications

    AP4C-F specs

    Detection
    Sensing technologyHydrogen Flame Spectrometry
    Detection
    • CWA (including 4th generation)
    • TIC / TIM
    • Gas, aerosols
    ModeInstant concentration or dose
    AlarmsFactory configuration based on customer needs
    Hydrogen
    H₂ running time
    • H₂ produced through embedded electrolyzer
    • 28 days H₂ autonomy on 1 water bottle
    Environment
    Storage temperature-39°C to +71°C / -38°F to +160°F
    Operating humidity93% HR (non condensing) @ 55°C (131°F)
    Environmental conditionsTested against heavy rain, salt, fog, ice & freeze
    Data & connectivity
    Data loggingBuilt in 32Mbit flash memory; around 530h data logging capability
    ConnectivityRS485 to a third-party solution or Proengin software solution
    Compliance & warranty
    Regulation / performance test
    • GAM EG 13/ Electromagnetic Compatibility Certifications
    • CE tests (EN 50270)
    Warranty1 year
    FAQ

    Common questions

    Is the AP4C-F the same as the handheld AP4C?
    No. The AP4C-F is a fixed chemical detector that provides continuous 24/7 monitoring for land or naval assets. The Proengin AP4C is a separate handheld detector for dismounted personnel.
    What does the AP4C-F detect?
    Proengin lists detection of CWA (including 4th generation), TIC / TIM, as gas and aerosols. Proengin describes it as able to detect a broad range of conventional and unconventional threats such as chemical warfare agents, toxic industrial chemicals, homemade terrorist mixtures, and nontraditional agents. It needs no library and no filters.
    Does someone need to operate it?
    No. Proengin describes alarm and sampling as fully automatic, requiring no action from the operator, for continuous 24/7 monitoring.
    How does it get hydrogen for flame spectrometry?
    H₂ is produced through an embedded electrolyzer. Proengin rates it at 28 days H₂ autonomy on 1 water bottle.
    How does it connect to a monitoring system?
    Through RS485 to a third-party solution or Proengin software solution. It also has built in 32Mbit flash memory for data logging. Proengin offers deliverables from full system integration to a ready to mount kit.
    What environment is it built for?
    Operating humidity is 93% HR (non condensing) @ 55°C (131°F), and it has been tested against heavy rain, salt, fog, ice & freeze.
    What warranty comes with it?
    Warranty is 1 year. Proengin notes that prepaid maintenance and extended warranty options are available upon initial acquisition.
    Is there a version that also detects biological threats?
    Yes, the AP4C-FB adds biological detection (virus, bacteria, spore) in the same housing family.
    Next step

    Protect the vessel. Protect the site.

    Tell us what you need to monitor, whether a naval platform, a strategic site or a transit hub, and request a quote on the AP4C-F and its deliverable options.

    CONTACT US