No products in the cart.

  • FarrWest Originals / Designed by the FarrWest kits solutions team

    FarrWest HCI Kit

    Hazardous Chemical Identification Colorimetric Paper Kit

    Your solution to assess and address chemical hazards swiftly and effectively. Six test papers and strips, sampling tools and an infrared thermometer come in a purpose built custom case with foam inserts, with an online training course and workbook included.

    • Complete portable colorimetric paper kit
    • Extensive H.C.I. Kit online training program
    • Purpose built custom case with foam inserts
    FarrWest HCI Kit open case with foam inserts holding an infrared thermometer, detection papers, vials, dropper bottle and transfer pipettes
    16Items in the kit
    6Test papers & strips
    -58 to 1000 F.Infrared thermometer range
    19Lessons in the online course
    How paper screening works

    Rule in. Rule out. Then go further.

    Colorimetric detection papers give responders a basic assessment process at a hazardous materials incident: a way to rule in or rule out potential chemical families and hazards, then couple the result with other assessment tools.

    1. Step 01

      Tools in the kit

      In the kit: 10 x Disposable Spatulas, 10 x Transfer Pipettes, 5 x 0.10mL Mini Sampler and 5 x 0.14mL vials.

    2. Step 02

      Run the papers

      Six colorimetric papers and strips. The course applies the principles of basic detection by using colorimetric analysis.

    3. Step 03

      Rule in or rule out

      Rule in or rule out potential chemical families and hazards.

    4. Step 04

      Go further

      The training is a prerequisite or supplement for higher level detection and air space monitoring. Detection papers allow the use of certain detection instruments within a larger detection scheme.

    Hot zoneConcepts apply
    Warm zoneConcepts apply

    The training is a basic approach, bringing concepts that can be used in the hot zone as well as the warm zone for further chemical analysis. It covers both the use and the pitfalls of this type of detection.

    Illustration
    Detection papers

    Six items, one screen

    The colorimetric papers and classifier strips at the heart of the kit. The online course walks responders through the kit, the set up and the acid/base threat step by step.

    • 01

      KI Detection Paper

      Detection paper

    • 02

      pH Paper

      Paper

    • 03

      Water Paper

      Paper

    • 04

      Fluoride Paper

      Paper

    • 05

      M8 Chemical Agent Paper

      Chemical agent paper

    • 06

      Spilfyter Chemical Classifier Strips

      Classifier strips

    Part of a larger scheme. Couple paper screening with other assessment tools, and the responder develops a strong approach to the detection analysis process.

    See the training
    Kit contains

    Sixteen items, one kit

    The kit is supplied in a purpose built custom case with foam inserts.

    Open FarrWest HCI Kit on a table with the wash bottle, transfer pipettes, paper boxes and infrared thermometer laid out while a gloved responder pipettes a sample into a vial A B C D E F
    The HCI Kit in use
    • A30mL Dropper Bottle
    • BTelescoping Alligator Clip
    • CLDPE Wash Bottle
    • D10 x Transfer Pipettes
    • E5 x 65mm Watch Glasses
    • FInfraRed Thermometer

    Detection papers 6 items

    • 01KI Detection Paper
    • 02pH Paper
    • 03Water Paper
    • 04Fluoride Paper
    • 05M8 Chemical Agent Paper
    • 06Spilfyter Chemical Classifier Strips

    Tools & equipment 9 items

    • 0730mL Dropper Bottle
    • 08Telescoping Alligator Clip
    • 09InfraRed Thermometer (-58 to 1000 F.)
    • 10LDPE Wash Bottle
    • 115 x 65mm Watch Glasses
    • 125 x 0.14mL vials (Ace-ID / Rigaku size)
    • 135 x 0.10mL Mini Sampler
    • 1410 x Disposable Spatulas
    • 1510 x Transfer Pipettes

    Training 1 item

    • 16Online Instruction Guide
    Tools in the kit

    Small samples, counted out

    Items come in fives and tens, and the vials are Ace-ID / Rigaku size.

    Gloved hands transferring a sample with a transfer pipette into a small vial beside a watch glass and an infrared thermometer
    Pipette, vial and watch glass
    5x

    0.14mL vials

    Ace-ID / Rigaku size

    5x

    0.10mL Mini Sampler

    5x

    65mm Watch Glasses

    10x

    Disposable Spatulas

    10x

    Transfer Pipettes

    30mL

    Dropper Bottle

    1x

    LDPE Wash Bottle

    1x

    Telescoping Alligator Clip

    -58 to 1000 F.

    InfraRed Thermometer

    Included training and support

    Training made by industry experts

    It's time to outfit your department with the comprehensive tools and state of the art training made by industry experts. Every HCI Kit includes an online course and a workbook.

    HAZMATACADEMY

    The premise behind this course is to identify the hazards that a responder may be confronted with at the scene of a hazardous materials incident. It leads the participant through the basic process of using the detection papers, and presents both the use and the pitfalls of this type of detection.

    The course presents in a step-by-step fashion, applying the principles of basic detection by using colorimetric analysis. Its simple approach gives the responder knowledge, skill and abilities to provide this basic assessment process.

    • Build upA prerequisite or supplement for higher level detection and air space monitoring.
    • Fit the schemeDetection papers allow the use of certain detection instruments within a larger detection scheme.
    • Narrow it downAble to rule in or rule out potential chemical families and hazards.
    About this course
    19Lessons
    0.5Hours of video content

    Curriculum includes

    1. 01Welcome to the course!
    2. 02The Kit
    3. 03The Set up
    4. 04The Acid/Base threat
    5. 05Always keep these on the potential chemicals list

    Workbook includedBecome engaged: view the video, use the workbook and work through the activities presented.

    Specifications

    Kit specifications

    Full contents of the FarrWest HCI Kit.

    Detection papers
    Papers
    • KI Detection Paper
    • pH Paper
    • Water Paper
    • Fluoride Paper
    • M8 Chemical Agent Paper
    StripsSpilfyter Chemical Classifier Strips
    Tools & equipment
    Dropper bottle30mL Dropper Bottle
    ClipTelescoping Alligator Clip
    ThermometerInfraRed Thermometer (-58 to 1000 F.)
    Wash bottleLDPE Wash Bottle
    Watch glasses5 x 65mm Watch Glasses
    Vials5 x 0.14mL vials (Ace-ID / Rigaku size)
    Mini sampler5 x 0.10mL Mini Sampler
    Spatulas10 x Disposable Spatulas
    Pipettes10 x Transfer Pipettes
    Case
    CasePurpose built custom case with foam inserts
    Kit typeComplete portable colorimetric paper kit
    Designed byThe FarrWest kits solutions team
    Training and support
    GuideOnline Instruction Guide
    Online courseHAZMATACADEMY course: 19 lessons, 0.5 hours of video content
    WorkbookWorkbook included
    ProgramExtensive H.C.I. Kit online training program
    FAQ

    Common questions

    What does the HCI Kit do?
    It is a complete portable colorimetric paper kit to assess and address chemical hazards swiftly and effectively. Paper screening lets a responder rule in or rule out potential chemical families and hazards, and is coupled with other assessment tools for a strong approach to the detection analysis process.
    Which detection papers are included?
    KI Detection Paper, pH Paper, Water Paper, Fluoride Paper, M8 Chemical Agent Paper and Spilfyter Chemical Classifier Strips.
    Is training included?
    Yes. The kit includes an Online Instruction Guide and the HAZMATACADEMY online course (19 lessons, 0.5 hours of video content), and a workbook is included. The course presents the use and pitfalls of this type of detection in a step-by-step fashion.
    Where do the training concepts apply?
    The training brings concepts that can be used in the hot zone as well as the warm zone for further chemical analysis.
    What size are the sample vials?
    The kit includes 5 x 0.14mL vials (Ace-ID / Rigaku size), along with 5 x 0.10mL Mini Sampler, 10 x Disposable Spatulas and 10 x Transfer Pipettes.
    What is the range of the infrared thermometer?
    -58 to 1000 F.
    How is the kit packed?
    It comes in a purpose built custom case with foam inserts. The kit is designed by the FarrWest kits solutions team.
    Next step

    Outfit your department with the HCI Kit

    Order the kit online, or reach the FarrWest team with questions about its contents and the included training.

    CONTACT US