The mPower Electronics VOXI LEL MP820 is a plug-and-play combustible gas sensor for fixed monitoring in oil, gas, chemical, and industrial applications.
The VOXI LEL MP820 is a point-type combustible gas transmitter designed with smart sensor technology and integral flameproof enclosure for fixed applications. Features catalytic combustible-gas sensors with auto-zeroing and offline calibration. Three-wire 4-20 mA analog and RS485 digital signal outputs standard. IP67 rated with IECEx certification. Suitable for oil & gas, petrochemical, chemical, metallurgical, pharmaceutical, semiconductor, and environmental monitoring applications.
| Performance | |
| Sensor | Catalytic combustion (LEL) sensor modules |
| Response time | 15s t90 |
| Outputs | Analog: 4-20mA (3 wires), Digital: RS-485, ModBus, 3 relays |
| Pressure | 86 to 106 kPa (0.85 to 1.05 atm) |
| Display | 4-digit segmented LCD |
| Power | |
| Power | <5W, 10-30 VDC supply |
| Physical | |
| Size | 8.9 x 5.9 x 4.9 in (226 × 150 x 125mm) |
| Weight | 5.7 lbs (2.6 kg) |
| Housing entries | 4 Conduit entries ¾" NPT, 1 Port M28x1 fitting |
| Housing | Explosion-proof aluminum alloy |
| Approvals & Warranty | |
| IP rating | IP-67 |
| Safety Certifications | IECEx Ex db IIC T6 Gb (non-Wireless), Ex tb IIIC T80°C Db (non-Wireless), Ex db ia IIC T6 Gb (Wireless), Ex ia tb IIIC T80oC Db (Wireless), CNEX Ex d IIC T6 |
| Warranty | 2 years |
| Other | |
| Temperature | -40° to +158°F (-40° to +70°C) |
| Humidity | 10% to 95% Relative Humidity (non-condensing) |
| Configuration | Via remote infrared programmer |
| Sampling | Diffusion |
| EMI/RFI | Compliant with EMC Directive 2014/30/EU |
| Installation | Pipe bolt and wall mount |
Calibration, repair and maintenance for your detection instruments.