No products in the cart.

  • 908 Devices / Portable mass spectrometer

    908 Devices MX908

    Multi-Threat Trace Detection and Identification

    The MX908 is a handheld high-pressure mass spectrometry (HPMS) trace detector for explosives, chemicals, and narcotics. 908 Devices describes it as a multi-mission, handheld mass spectrometer used by elite responders conducting chemical, explosive, priority drug, and hazmat operations around the world.

    <45sResults in <45s
    NanogramLevel trace detection
    >3 hoursContinuous operation, hot swappable
    IP-54Chemical resistant housing
    908 Devices MX908 handheld mass spectrometer showing a fentanyl alarm on its display
    HPMSHigh-pressure mass spectrometry
    MIL-STD-810GRuggedness
    High-pressure mass spectrometry
    Real-Time Threats.
    Real-Time Detection.

    The MX908 leverages high-pressure mass spectrometry (HPMS) to deliver dramatically enhanced sensitivity and broader threat category coverage, in a handheld that 908 Devices calls a second-generation tool for elite responders in chemical, explosive, drug and priority hazmat scenarios.

    According to 908 Devices, HPMS accurately discriminates priority threats from the broad range of interferents that lead to false alarms with other commonly used technologies, and one device can analyze any sample regardless of size or phase of matter.

    Multi-mode threat detection
    Solids
    Liquids
    Vapors
    Aerosols

    Aerosol sampling is covered by the Aero module, below.

    Sample to answer

    From swab or air to a named threat

    One workflow for every phase of matter: introduce the sample, let on-board HPMS analytics run, read the alarm, then hand the result to the team.

    01

    Introduce the sample

    Swab, vapor or aerosol: solid, liquid, gas/vapor and aerosol sample types.

    Swab · solids & liquidsRapid trace-to-bulk solid/liquid analysis via thermal desorption swabs
    Vapor · gasContinuous gas/vapor analysis
    Aerosol · modular accessoryPeriodic aerosol analysis via thermal desorption
    02

    Analyze on board

    Powered by mass spectrometry, with heightened sensitivity and selectivity.

    • Ionization sourceNon-radioactive, internal ionization, variable energy, dual polarity
    • SoftwareEmbedded, self-contained, on-board analytics
    • Mission modeSpecialized software and hardware configurations to optimize performance for hunting certain chemical classes
    03

    Read the result

    Unmistakable audio and visual alerts on a simple interface.

    • SpeedResults in <45s
    • Alarm typeAudio and visual for both detection and identification
    • DisplayAdjustable ultra-bright backlit display for direct sunlight and nighttime conditions, 12.7 cm (5 in)
    04

    Share & get support

    Move the event off the instrument and into the case file.

    • WirelessExport wirelessly via Bluetooth connection with any compatible iOS or Android device
    • ManualExport manually using included USB drive
    • Remote appAdd case information with the MX908 remote application
    • Reachback24/7 Reachback support for data analysis by forensic chemists
    Gloved hands holding an MX908 sample swab over a sample tray next to the MX908
    Step 01 · swab sampling beside the MX908
    MX908 beside a phone running the MX908 remote application's History screen for an event
    Step 04 · MX908 with the remote application
    Sampling modules

    Three modules, four phases

    MX908 is equipped with modular accessories for ease of transition between solid, liquid, vapor, and aerosol sample types.

    Tell us what you sample and FarrWest will confirm the configuration with your quote.

    MX908 Trace sampling module, two-part black body with grey ring
    Trace module
    MX908 Vapor sampling module with white cap and stainless fitting
    Vapor module
    MX908 Aero aerosol sampling module, three-quarter view
    Aero module
    Threat landscape

    Bulk to true trace

    908 Devices: HPMS enables responders to detect and identify chemical hazards from bulk to true trace concentrations,. The grid below maps that range against the scenes responders face.

    Purity / concentration
    High>70%
    Intermediate10–70%
    Low<10%
    BulkVisible · grams · PPM
    Stockpiles
    Hazmat event
    Contraband
    ResidueBarely visible · milligrams · PPM/PPB
    Clandestine labs
    Chemical munitions
    Drugs
    TraceInvisible · nanograms · PPB
    WMD event
    Vehicle inspection
    Screening
    Your mission defines your mode

    Three hunters, one device

    Based on your specific mission objectives, choose an MX908 Mission Mode that leverages specialized software and hardware configurations to optimize performance for hunting certain chemical classes.

    Officer carrying an MX908 beside a police vehicle
    Mission mode 01

    Drug Hunter

    Targets
    • Methamphetamine
    • Heroin
    • Cocaine
    • Cannabinoids
    • Fentanyl and 2000+ Fentanyl Analogs
    • Cathinones
    • And More…
    • Identify narcotics in low concentration mixtures (well below 5%)
    • Establish trace chemical evidence linkages for interdiction, checkpoint operations, and more
    • Improve officer safety with limited exposure risk
    • Fentanyl Classifier provides coverage for 2000+ fentanyl analogs

    “The MX908 is the only device capable of classifying fentanyl analogs without a library-based approach.”908 Devices

    Two responders in respirators and chemical protective suits reading an MX908
    Mission mode 02

    CW Hunter

    Targets
    • Novichoks or A-series Agents
    • Legacy Warfare Agents (G, V, and H-series)
    • Pharmaceutical Based Agents (including fentanyl, carfentanil, and remifentanil)
    • Quantify chemical warfare agents in real time
    • Identifying Novichoks and other CWAs by name is essential for decontamination and medical response
    • Allow for broad threat coverage in any state with a single device
    • Remote area monitoring with MX908 Beacon

    “Only field deployable detector for trace identification of Novichoks.”908 Devices

    EOD technician in a bomb suit using an MX908 with a sampling probe
    Mission mode 03

    Explosive Hunter

    Targets
    • Homemade Explosives
    • Commercial Explosives
    • Military Explosives
    • Precursors
    • Identify trace explosive residues
    • Identify explosives by name to guide response
    • Analyze samples safely with no threat of igniting sensitive materials
    • Identify aerosolized chemical threats dispersed from IEDs and other munitions
    • Establish trace chemical evidence linkages for checkpoint operations, HME lab response, and more
    In the field

    Probable cause, less exposure

    908 Devices states that, with the enhanced selectivity of HPMS, users can conduct field analysis of unknown substances at trace levels. It says the MX908 lets operators rapidly assess threat levels, establish reliable probable cause and prioritize investigatory resources, all while reducing operator exposure.

    Officer's hands operating an MX908 on the hood of a police vehicle
    MX908 operated beside a police vehicle
    • 01

      Establish probable cause with trace evidence

      Nanogram level detection identifies threats while keeping officers safe.

    • 02

      Rugged: MIL-STD-810G

      MX908 is rugged and meets the requirements for use in harsh environments. The housing is IP-54 rated and chemical resistant for spray/splash and wipe-down decontamination.

    • 03

      Hot-swappable power

      Replaceable, hot swappable batteries with >3 hours of continuous operation (2 spare batteries included).

    • 04

      Fast start up, low maintenance

      A simple interface and unmistakable audio and visual alerts, on an ultra-bright display readable in direct sunlight and at night.

    Missions

    • Drug Interdictions and Investigations
    • Clandestine Laboratory Exploitation
    • EOD
    • Border Security
    • HazMat Response
    • Checkpoint Security
    • Postal Security
    • Event Security
    Gloved hands holding an MX908 showing a fentanyl alarm
    Gloved operation
    Responder in an orange protective suit holding an MX908 showing a Novichok alarm
    Hazmat response
    Responders in red uniforms being briefed by a presenter holding an MX908
    Responder briefing
    MX908 Aero · aerosol sampling module

    Close the aerosol gap

    The MX908 Aero enables operators to detect and identify aerosolized threats, such as Chemical Warfare Agents (CWAs) and Pharmaceutical-based Agents (PBAs), which represent a critical gap in existing trace chemical detection solutions.

    An aerosol is a suspension of fine solid or liquid particles that keep the physical properties of their solid or liquid state but behave like a vapor, which makes traditional vapor detectors ineffective against them. The Aero leverages proven MX908 sampling technologies and analysis mechanics to address this threat.

    • 01

      Vapor and aerosol together

      Simultaneous monitoring, detection, and identification of both vapor and aerosol threats.

    • 02

      Fits new and fielded units

      Optional accessory can be quickly deployed to fielded units or be purchased with new MX908 devices.

    Aero target groups
    • A-series agents (Novichoks)
    • V-series agents
    • G-series agents
    • Blister agents
    • Fast-acting incapacitating agents
    • Lachrymatory agents
    MX908 with the Aero module fitted and shoulder straps, display showing an A-232 Novichok alarm MX908 Aero module on its own
    MX908 with the Aero module fitted
    Aerosol plume rising over desert terrain
    Aerosol dispersed from an explosive device
    Operator in protective gear carrying an MX908 across desert terrain for post-blast analysis
    On-site post-blast analysis with the Aero
    MX908 Beacon · area monitoring

    Area monitoring for CWAs and PBAs

    With the addition of MX908 Beacon, operators can augment their area monitoring capability to provide real-time identification of aerosol and vapor chemical warfare agents (CWAs) and pharmaceutical based agents (PBAs) for extended durations, adding a layer of protection for special events, hazmat response and critical infrastructure.

    MX908 Beacon case shown against a stadium with signal rings, illustrating key-event monitoring
    Key events · Beacon area monitoring
    • Remote monitoring anywhere in the world: a remote communications package lets users operate and monitor multiple Beacons while sharing real-time data with their team.
    • Trace identification (low-mid ppb/ng) of threats
    • Discreet, environmentally hardened case
    • Extended operation and standby time, with easy data sharing capability
    • 908 Devices lists the Beacon as the “Only area monitor for vapor and aerosol identification”.
    Configuration

    Ask FarrWest about the Beacon configuration for your MX908.

    Open MX908 Beacon case with an MX908 in the lower tray and pouches in the lid
    MX908 Beacon, case open
    MX908 Beacon Portal web page showing a Beacon connection and its alarm log
    Beacon Portal: real-time results, remote control of multiple units

    Remote management

    Monitor multiple sessions in a single portal. Start/stop scans, monitor results, share data. Alerts are sent discreetly to user connected computer or mobile devices.

    Size
    22 x 17.9 x 10.4 in
    Weight
    <45lbs (20.4 kg)
    Power
    Imbedded Li Ion batteries or shore power for 8+ hours of continuous operations
    Comms
    User-provided cellular device/WiFi hotspot to secure web page

    Area monitoring for

    • Hazmat response
    • Key events
    • Military operations
    • Critical infrastructure
    • Exclusion zone monitoring
    • Decontamination monitoring
    • VIP Protection
    • Clandestine lab operations
    • CBRN Vehicles
    Specifications

    The numbers

    Physical
    Size29.8 x 21.6 x 12.2 cm (11.8 x 8.5 x 4.8 in)
    Weight≤4.3 kg (9.5 lbs); varies based on module, accessories
    DisplayAdjustable ultra-bright backlit display for direct sunlight and nighttime conditions, 12.7 cm (5 in)
    PowerReplaceable, hot swappable batteries with >3 hours of continuous operation (2 spare batteries included)
    Analysis
    TechnologyHigh-pressure mass spectrometry (HPMS)
    Ionization sourceNon-radioactive, internal ionization, variable energy, dual polarity
    Sample introductionRapid trace-to-bulk solid/liquid analysis via thermal desorption swabs; continuous gas/vapor analysis with periodic aerosol analysis via thermal desorption
    Trace detectionTrace detection (low - mid nanograms) · Results in <45s
    Alarm typeAudio and visual for both detection and identification
    SoftwareEmbedded, self-contained, on-board analytics
    Data
    Data export
    • Export wirelessly via Bluetooth connection with any compatible iOS or Android device
    • Export manually using included USB drive
    Environment
    DecontaminationIP-54 rated, chemical resistant housing spray/splash and wipe down
    Operating temperature0°–40° C (32°-110° F)
    Storage temperature-20°–60° C (-4°-140° F)
    RuggednessMIL-STD-810G
    Mission mode targets
    Drug HunterMethamphetamine · Heroin · Cocaine · Cannabinoids · Fentanyl and 2000+ Fentanyl Analogs · Cathinones · And More…
    CW HunterNovichoks or A-series Agents · Legacy Warfare Agents (G, V, and H-series) · Pharmaceutical Based Agents (including fentanyl, carfentanil, and remifentanil)
    Explosive HunterHomemade Explosives · Commercial Explosives · Military Explosives · Precursors
    Drug threat categories
    Threat categories
    • Fentanyls/Synthetic Opioids
    • Synthetic Cannabinoids
    • Synthetic Cathinones
    • Traditional drugs such as: Cocaine, Heroin, Meth, MDMA, and more
    • Precursors
    Fentanyl analogsDrug Hunter unlocks detection capabilities for more than 2000 fentanyl variants.
    Target group · targets
    A-series agents (Novichoks)A-230, A-232, A-234
    V-series agentsVE, VM, VS, VX, VX Acid RVX/CVX
    G-series agentsGA, GB, GD, GF
    Blister agentsHD
    Fast-acting incapacitating agentsFentanyl and analogs (2000+), U-series, AH-7921
    Lachrymatory agentsCapsaicin
    MX908 Beacon
    Size22 x 17.9 x 10.4 in
    Weight<45lbs (20.4 kg)
    PowerImbedded Li Ion batteries or shore power for 8+ hours of continuous operations
    CommunicationsUser-provided cellular device/WiFi hotspot to secure web page
    Sample introductionContinuous gas/vapor analysis with periodic aerosol analysis via thermal desorption
    Data exportData export from secure web server.
    Threat categoriesA-series agents (Novichoks) · V-series agents · G-series agents · HD Mustard · Pharmaceutical-based agents · Lachrymatory agents

    908 Devices notes that MX908 is subject to export controls, including those of the Export Administration Regulations of the U.S. Department of Commerce, which may restrict or require licenses for export from the United States and re-export.

    FAQ

    Common questions

    What can the MX908 detect?
    It depends on the mission mode. Drug Hunter targets methamphetamine, heroin, cocaine, cannabinoids, fentanyl and 2000+ fentanyl analogs, cathinones and more. CW Hunter targets Novichoks or A-series agents, legacy warfare agents (G, V, and H-series) and pharmaceutical based agents. Explosive Hunter targets homemade, commercial and military explosives and precursors. See the mission modes above.
    What kinds of samples can it analyze?
    Solids, liquids, vapors and aerosols: rapid trace-to-bulk solid/liquid analysis via thermal desorption swabs, and continuous gas/vapor analysis with periodic aerosol analysis via thermal desorption. MX908 is equipped with modular accessories for switching between sample types; aerosol sampling uses the Aero module.
    How fast and how sensitive is it?
    Results in <45s, with trace detection in the low to mid nanograms.
    Does it use a radioactive source?
    No. The ionization source is non-radioactive, internal ionization, variable energy, dual polarity.
    How long does it run on batteries?
    Replaceable, hot swappable batteries with >3 hours of continuous operation, and 2 spare batteries are included.
    How do I get results off the instrument?
    Export wirelessly via Bluetooth to any compatible iOS or Android device, or manually with the included USB drive. Case information can be added with the MX908 remote application, and 908 Devices lists 24/7 reachback support for data analysis by forensic chemists.
    Can the Aero module be added to an MX908 we already own?
    The Aero is an optional accessory that can be quickly deployed to fielded units or be purchased with new MX908 devices. See MX908 with Aerosol Module, or request a quote and we will confirm the configuration.
    How is the Beacon configured with an MX908?
    For your specific setup, request a quote and FarrWest will recommend the configuration. The Beacon uses a user-provided cellular device or WiFi hotspot to reach its secure web page.
    Which modules come with an MX908?
    Tell us which samples you need to cover when you request a quote and we will confirm the configuration with your quote.
    Does FarrWest offer service and support?
    The FarrWest Repair Depot provides OEM-certified service and support on every product we deliver. When a repair or calibration falls outside our in-house scope, we coordinate directly with the third-party manufacturer and manage the logistics end to end.
    Next step

    Scope your MX908

    Tell us the mission and the samples you face: drugs, chemical warfare agents, explosives or area monitoring. FarrWest will come back to you on the MX908, Aero and Beacon configuration that fits.

    CONTACT US