No products in the cart.

    • RadFlash
    • RadFlash — view 2
    Polimaster

    RadFlash

    POLIMASTER RadFlash is a compact electronic personal dosimeter for real-time radiation monitoring in healthcare, diagnostics, and other occupational exposure settings.

    Request a quote
    Quotes typically returned within 1 business day.
    or
    Add to Quote
    Questions? Talk to a specialist210.566.1857 · sales@farrwest.com
    Dose indication range (Sv)
    0.01 µSv to 12 Sv
    Ingress protection
    IP67
    Weight
    50 g
    Dimensions
    63 × 50 × 18 mm
    Operating temperature
    –10 °С to 50 °С

    Overview

    RadFlash® series of electronic personal dosimeters offers a compact and versatile solution for personal radiation monitoring. The dosimeter measures personal dose equivalent and dose equivalent rate of X-ray (continuous and pulsed) and gamma radiation. Features real-time data monitoring via Bluetooth, PoliSync™ software for setup and history readout, Polismart® mobile app for real-time exposure monitoring, visual and audible alarms, wireless charging, and clips/wristband for different wearing options. Available in three modifications: RadFlash® Sv, RadFlash® R, and RadFlash® mrem to support different regional standards. Suitable for healthcare, interventional radiology, medical physicists, radioisotope labs, X-ray diagnostics, customs/border control, and anyone working under radiation exposure risk.

    • PoliSync™ software for setup and history readout
    • Polismart® app for real-time exposure monitoring
    • Clips and a wristband for different wearing options
    • Resistance to cleaning and disinfection agents
    • On-screen, audible and visual (LED) alarms
    • Data transfer via Bluetooth

    Specifications

    Performance
    DetectorGeiger-Mueller tube
    Dose rate indication range (Sv)0.01 µSv/h to 1.2 Sv/h
    Dose rate measurement range (Sv)0.1 µSv/h to 1 Sv/h
    Permissible limits of basic relative error of dose measurement±15 %
    Dose indication range (Sv)0.01 µSv to 12 Sv
    Dose measurement range (Sv)1 µSv to 10 Sv
    Permissible limits of basic relative error of dose rate measurement±15 %
    Accuracy (Ref. 137Cs)±5 % at 800 µSv/h
    Energy range30 keV to 3 MeV
    Combined energy and angular response (Ref. 137Cs)−29 % to +67 % (30 keV to 1.5 MeV; 0° to 60°; IEC 61526:2024 compliant)

    Calibration & repair from FarrWest

    Calibration, repair and maintenance for your detection instruments.

    Service programs →Scheduled calibration & maintenanceRepair depot →Start a repairTraining →Courses for your team

    CONTACT US