Built for personal protection and leak detection, the MultiRAE Lite comes in pumped and diffusion versions and offers the broadest selection of sensor options in its class. Configure it for exactly the gases your job and your compliance requirements call for, with wireless as an option.
Diffusion · Pumped
The two versions share a display, alarms and most of the sensor list, but not all of it. The sampling method decides which sensors you can fit, whether AutoRAE 2 can test and calibrate the monitor, and how much it weighs on a belt. Pick the version before you pick the gases.


* Runtimes are for non-wireless monitors. Alkaline adapter with 4 x AA batteries: ~6-hr. (pumped) / 8-hr. (diffusion) runtime.
The MultiRAE Lite is a one-to-six-gas monitor. It can be configured to exactly meet the detection needs and compliance requirements of different countries, industries and applications, from one to six gases.
Electrochemical sensors for toxic gases and oxygen. 20+ electrochemical sensors are available on the Lite, including a CO + H2S combination sensor.
Catalytic and NDIR sensors for combustibles. The catalytic LEL sensor fits either version; the NDIR methane sensors require the pumped version.
A photoionization detector for volatile organic compounds. The pumped kit ships with Technical Note TN-106: ionization energies and correction factors for 300+ VOCs.
An NDIR sensor for CO2, available on both the pumped and diffusion versions.
Intelligent sensors store calibration data, so they can be swapped in the field. The sensors are interchangeable and field-replaceable; RAE Systems recommends calibrating sensors on installation. Tell us the gases you monitor and the version you need, and we will spec the build with you.
MultiRAE-series sensors and power packs we list that match the Lite's ranges. Mind the version: the PID and NDIR combustible sensors need the pumped Lite.
Alkaline runtime is for non-wireless monitors.
Unmistakable five-way local and remote notification of alarm conditions, including a Man Down Alarm with pre-alarm. Four channels are on the monitor itself; the fifth reaches commanders and safety officers when the wireless option is fitted.
95 dB @ 30 cm.
Vibration indication of alarm conditions.
Flashing bright red LEDs. The diffusion version adds an extra alarm buzzer and LEDs.
On-screen indication of alarm conditions, with STEL, TWA, peak and minimum values.
Real-time remote notification of alarms and Man Down to the safety team.
Wireless and non-wireless configurations are available. With the optional built-in RF modem, the Lite gives commanders and safety officers real-time access to instrument readings and alarm status from any location, for better situational awareness and faster incident response.
Additional equipment and/or software licenses may be required to enable remote wireless monitoring and alarm transmission. Ask us which network fits your site.
A large icon-driven display, a datalog that runs for months, and maintenance designed around replaceable sensors and a plug-and-play battery.

Monochrome graphical LCD display (128 x 160) with backlighting and an automatic screen "flip" feature. Easy-to-use, icon-driven user interface with three keys: MODE, Y/+ and N/-.
6 months for 5 sensors at 1-minute intervals, 24/7. User-configurable datalogging intervals from 1 to 3,600 seconds.
Easy maintenance with replaceable sensors and a plug-and-play battery; intelligent sensors can be swapped in the field. Pump replacement is a service job: only authorized personnel should replace the pumps.
Fully automatic bump testing and calibration, plus data download and instrument set-up through the AutoRAE 2 Automatic Test and Calibration System.
Device Management with Honeywell SafetySuite.
Honeywell positions the MultiRAE Lite for personal protection and multi-gas leak detection in industries such as those below, and for fire overhaul.
| Instrument | |
|---|---|
| Models | PGM-6208 (pumped) and PGM-6208D (diffusion) |
| Size | Pumped model: 7.6" H x 3.8" W x 2.6" D (193 x 96.5 x 66 mm) Diffusion model: 6.9" x 3.8" x 2.2" (175 x 96.5 x 56 mm) |
| Weight | Pumped model: 31 oz (880 g) Diffusion model: 26.8 oz (760 g) |
| Sampling | Built-in pump or diffusion |
| Pump flow | Average flow rate, pumped: 250 cc/min. Auto shutoff in low-flow conditions |
| Calibration | Automatic with AutoRAE 2 Test and Calibration System (pumped version only) or manual |
| Display & controls | |
| Display | Monochrome graphical LCD display (128 x 160) with backlighting. Automatic screen "flip" feature |
| Backlight | Activated automatically in dim ambient lighting conditions, when monitor is in alarm, or with a button press |
| Display readout | Real-time reading of gas concentrations; PID measurement gas and correction factor; Man Down Alarm on/off; visual compliance indicator; battery status; datalogging on/off; wireless on/off and reception quality. STEL, TWA, peak, and minimum values |
| Keypad | 3 operation and programming keys (MODE, Y/+, and N/-) |
| Languages | Arabic, Chinese, Czech, Danish, Dutch, English, French, German, Indonesian, Italian, Japanese, Korean, Norwegian, Polish, Portuguese, Russian, Spanish, Swedish, and Turkish |
| Environment | |
| Operating temperature | -4° to 122°F (-20° to 50°C) |
| Humidity | 0% to 95% relative humidity (non-condensing) |
| Dust & water | IP-65 (pumped); IP-67 (diffusion) ingress protection rating |
| Sensor | Range | Resolution | Note |
|---|---|---|---|
| Photoionization (PID) | |||
| VOC 10.6 eV | 0 to 1,000 ppm | 1 ppm | Pumped version only |
| Combustibles & CO2 | |||
| Catalytic LEL | 0 to 100% LEL | 1% LEL | |
| NDIR (0-100% LEL methane) | 0 to 100% LEL | 1% LEL | Pumped version |
| NDIR (0-100% Vol. methane) | 0 to 100% Vol. | 0.1% Vol. | Pumped version |
| Carbon dioxide (CO2) NDIR | 0 to 50,000 ppm | 100 ppm | |
| Electrochemical | |||
| Ammonia (NH3) | 0 to 100 ppm | 1 ppm | |
| Carbon monoxide (CO) | 0 to 500 ppm | 1 ppm | |
| CO, ext. range | 0 to 2,000 ppm | 10 ppm | |
| CO, H2-compensated | 0 to 2,000 ppm | 10 ppm | |
| CO + H2S combo | 0 to 500 ppm / 0 to 200 ppm | 1 ppm / 0.1 ppm | Two-gas combination sensor |
| Chlorine (Cl2) | 0 to 50 ppm | 0.1 ppm | |
| Chlorine dioxide (ClO2) | 0 to 1 ppm | 0.03 ppm | |
| Ethylene oxide (EtO-A) | 0 to 100 ppm | 0.5 ppm | |
| Ethylene oxide (EtO-B) | 0 to 10 ppm | 0.1 ppm | |
| Ethylene oxide (EtO-C), ext. range | 0 to 500 ppm | 10 ppm | Diffusion only |
| Formaldehyde (HCHO) | 0 to 10 ppm | ||
| Hydrogen (H2) | 0 to 1,000 ppm | 10 ppm | Diffusion only |
| Hydrogen cyanide (HCN) | 0 to 50 ppm | 0.5 ppm | |
| Hydrogen sulfide (H2S) | 0 to 100 ppm | 0.1 ppm | |
| H2S, ext. range | 0 to 1,000 ppm | 1 ppm | Diffusion only |
| Methyl mercaptan (CH3-SH) | 0 to 10 ppm | 0.1 ppm | |
| Nitric oxide (NO) | 0 to 250 ppm | 0.5 ppm | |
| Nitrogen dioxide (NO2) | 0 to 20 ppm | 0.1 ppm | |
| Oxygen (O2) | 0 to 30% Vol. | 0.1% Vol. | |
| Oxygen (Liq O2) | 0 to 30% Vol. | 0.1% Vol. | |
| Phosphine (PH3) | 0 to 20 ppm | 0.1 ppm | |
| Phosphine H (PH3 H) | 0 to 20 ppm | 0.1 ppm | |
| Sulfur dioxide (SO2) | 0 to 20 ppm | 0.1 ppm | |
| Battery (specification for non-wireless monitors) | |
|---|---|
| Rechargeable Li-ion | ~12-hr. (pumped)/18-hr. (diffusion) runtime |
| Extended duration Li-ion | ~18-hr. (pumped)/28-hr. (diffusion) runtime |
| Alkaline adapter | 4 x AA batteries ~6-hr. (pumped)/8-hr. (diffusion) runtime |
| Data | |
| Datalogging | Continuous datalogging (6 months for 5 sensors at 1-minute intervals, 24/7) User-configurable datalogging intervals (from 1 to 3,600 seconds) |
| Data download | Data download and instrument set-up and upgrades on PC via travel charger or AutoRAE 2 Automatic Test and Calibration System (pumped version only) |
| Device management | Device Management with Honeywell SafetySuite |
| Alarms | |
|---|---|
| Alarm notification | Wireless remote alarm notification; audible (95 dB @ 30 cm), vibration, visible (flashing bright red LEDs), and on-screen indication of alarm conditions |
| Man Down | Man Down Alarm with pre-alarm and real-time remote wireless notification |
| Wireless (optional) | |
| Wireless | Wireless data and alarm status transmission via built-in RF modem (optional). Additional equipment and/or software licenses may be required to enable remote wireless monitoring and alarm transmission. |
| Network | ProRAE Guardian Real-Time Wireless Safety System or EchoView Host-based Closed-Loop System |
| Range (typical) | MultiRAE Lite to RAELink3 Mesh modem ~330 feet (100 meters) MultiRAE Lite to EchoView Host, RAEMesh Reader or RAEPoint ~200 meters MultiRAE Lite to Wi-Fi Access Point - 330 feet (100 meters) |
| Frequency | ISM license free band. IEEE 802.15.4 Sub 1GHz - Wi-Fi 802.11 b/g |
| Radio module | Supports RM900A |
| Wireless approvals | FCC Part 15 |
| Safety certifications | |
|---|---|
| CSA | Class I, Division 1, Groups A, B, C and D, T4 / Class II, Division 1, Groups E, F, G T85°C |
| ATEX | II 1G Ex ia IIC T4 Ga / 2G Ex ia d IIC T4 Gb with IR Sensor installed / I M1 Ex ia I Ma |
| IECEx | Ex ia IIC T4 Ga / Ex ia d IIC T4 Gb with IR Sensor installed / I M1 Ex ia I Ma |
| IECEx / ANZEx | Ex ia IIC T4 Ga / Ex ia d IIC T4 Gb with IR Sensor installed / Ex ia I Ma |
| Performance | |
| Performance tests | LEL CSA C22.2 No. 152; ISA-12.13.01 |
| Standard contents | Pumped | Diffusion |
|---|---|---|
| Monitor with sampling mode, sensors, battery, and wireless options as specified; protective rubber boot, external filter, and belt clip installed | Yellow rubber boot | Yellow rubber boot |
| Travel charger / PC communications adapter | Yes | Yes |
| AC adapter | Yes | Yes |
| PC communication cable | Yes | Yes |
| Calibration adapter | Yes | Yes |
| Toolkit | Yes | Yes |
| QuickStart Guide | Yes | Yes |
| Calibration and test certificate | Yes | Yes |
| Alkaline battery adapter | Included with rechargeable configurations only | Included with rechargeable configurations only |
| 3 spare external filters | Yes | No |
| 10 charcoal filters (reduce CO sensor's cross-sensitivity to VOCs) | Yes | No |
| PID sensor cap removal tool | Yes | No |
| Technical Note TN-106 with ionization energies and correction factors for 300+ VOCs | Yes | No |
| Desktop charging / PC communications cradle | No | No |
| Pelican case | Optional | Optional |
Runtimes are for non-wireless monitors.
Honeywell warranty service and calibration and repair through FarrWest, plus the datasheet for your files.
Other components, sensors and consumables carry shorter terms; see the manufacturer's warranty terms for the full list.
Only authorized personnel should replace the pumps. Any attempt to change the pump will void the warranty. Contact us or Honeywell about pump replacement.
FarrWest is a pre-approved vendor on BuyBoard and Purchasing Cooperative of America (PCA). Government agencies can buy on competitively-bid cooperative contracts, with no lengthy RFP.
How co-op buying worksServiceFarrWest is a Honeywell Authorized Service Provider for BW and RAE Systems gas detection, with repair and calibration in our own Repair Depot in San Antonio, Texas.
Warranty serviceSince 2004Serving Hazmat, Fire, Police, EMS, and Specialty Vehicle operations nationwide since 2004, with expert support, training, and service after the sale.
About FarrWestSide-by-side specifications and which model fits which job.
Open comparisonRelatedHoneywell QRAE 3 monitors one to four gases, incl. H2S, CO and HCN, in an IP-65/67 case, pumped/diffusion. Quote and authorized Honeywell…
View productRelatedHoneywell MultiRAE is a pumped six-gas monitor with 25 sensor options, including PID for VOCs and NDIR for combustibles and CO2. FarrWest…
View productThe Lite is built to your configuration. Tell us pumped or diffusion, the gases you need to see, and whether you want wireless, and we will come back with a build and a quote.