The QRAE 3 is a compact monitor for one to four gases: oxygen, combustibles and a short list of toxics, in pumped or diffusion form. The MultiRAE family is larger and configurable to six readings, with a photoionization detector (PID) for VOCs, infrared sensors and 25 or more sensor options. The MultiRAE Pro adds gamma radiation. If the job involves VOCs or unknown chemicals, it is a MultiRAE job. If crews need a light four-gas monitor worn all shift, look at the QRAE 3.
Both monitors are Honeywell RAE Systems instruments. They share the same alarm package, optional wireless and AutoRAE 2 docking, so the choice comes down to what you need to detect and how the monitor will be carried.
QRAE 3 vs MultiRAE family, from Honeywell datasheets
| QRAE 3 | MultiRAE (PGM-6228) | How the Lite and Pro differ | |
|---|---|---|---|
| Gases at once | Up to 4 sensors | Up to 6 readings (6 needs a two-gas combo sensor) | Same |
| Sensor options | Catalytic LEL, O2, electrochemical H2S, CO, SO2, HCN | 25 options: PID, catalytic and NDIR combustibles, CO2 NDIR, electrochemical toxics and O2 | Lite: over 25; Pro: over 25 incl. ppb PID and gamma |
| VOCs (PID, 10.6 eV) | Not offered | 0 to 5,000 ppm, 0.1 ppm resolution | Lite: 0 to 1,000 ppm, 1 ppm (pumped only); Pro adds ppb PID, 0 to 2,000 ppm at 10 ppb |
| Gamma radiation | No | No | Pro: 0 to 20,000 μRem/h, CsI(Tl) scintillator |
| Sampling | Pumped or diffusion; pump samples through tubing up to 98 ft (30 m) | Built-in pump, 250 cc/min average, auto shutoff on low flow | Lite: pumped or diffusion; Pro: pumped |
| Size | Diffusion 5.5 x 3.2 x 1.5 in; pumped 5.7 x 3.2 x 1.7 in | 7.6 x 3.8 x 2.6 in | Lite diffusion 6.9 x 3.8 x 2.2 in |
| Weight | 12.9 oz diffusion; 14.5 oz pumped | 31 oz (880 g) | Lite diffusion 26.8 oz (760 g) |
| Display and keys | 128 x 80 graphic display, 1.57 x 1.06 in, backlit, rotates 180°; 2 buttons | 128 x 160 graphic LCD, backlit, automatic flip; 3 keys | Same as MultiRAE |
| Battery runtime | Li-ion: 14 h diffusion, 11 h pumped (no wireless); 10 h and 8 h with wireless | Li-ion ~12 h; extended Li-ion ~18 h; 4 x AA alkaline ~6 h (non-wireless units) | Lite diffusion: ~18 h standard, ~28 h extended |
| Datalogging | 3 months, 4 sensors at 1-minute intervals | 6 months, 5 sensors at 1-minute intervals | Same as MultiRAE |
| Wireless (optional) | Built-in RF modem, 868 or 900 MHz mesh | RF modem (sub-1 GHz mesh) and Wi-Fi 802.11 b/g | Same options |
| Ingress rating | IP-65 pumped; IP-67 diffusion | IP-65 | Lite: IP-65 pumped, IP-67 diffusion; Pro: IP-65 |
| Hazardous locations (US/Canada) | Class I, Division 1, Groups A, B, C, D | Class I, Div. 1, Groups A–D, T4; Class II, Div. 1, Groups E, F, G, T85°C | Same as MultiRAE |
| Operating temperature | -4 to 122 °F (-20 to 50 °C) | -4 to 122 °F (-20 to 50 °C) | Same |
Source: Honeywell datasheets: QRAE 3 DS-1095 (05/18); MultiRAE DS-1070-11, MultiRAE Lite DS-1071-11, MultiRAE Pro DS-1068-11 (all 04/18)
The biggest difference is the sensor list. Honeywell's QRAE 3 datasheet names six sensor types: a catalytic bead for combustibles, a liquid-electrolyte oxygen sensor, and electrochemical cells for hydrogen sulfide, carbon monoxide, sulfur dioxide and hydrogen cyanide. You pick up to four. That covers classic confined-space work (O2, LEL, H2S, CO) and lets fire crews add HCN.
The MultiRAE adds three kinds of sensing the QRAE 3 does not have:
MultiRAE sensors store their own calibration data, so they can be swapped in the field. Honeywell still recommends calibrating each sensor when it is installed. The QRAE 3 also has field-replaceable sensors and an easy-access compartment for the sensors, pump, filter and battery.
A diffusion monitor reads the air that reaches its sensors on its own. It is lighter and simpler, which suits a personal monitor clipped on for a whole shift. A pumped monitor pulls a sample through a hose. That lets you test a tank, manhole or vault from outside before anyone goes in, and check a space at different depths.
The QRAE 3 comes either way. Honeywell rates the pumped version to sample through up to 98 ft of tubing and adds a pump-stall alarm. The diffusion version is lighter (12.9 oz against 14.5 oz) and carries the higher IP-67 rating. The standard MultiRAE and the MultiRAE Pro are pumped only, at about 250 cc/min with automatic shutoff if flow drops. The MultiRAE Lite is the only MultiRAE sold in a diffusion version, and its PID and NDIR combustible sensors require the pumped build.
Wireless is optional on both. Honeywell sells wireless and non-wireless versions of each, and notes that remote monitoring may need extra equipment or software licenses. With the radio fitted, readings and alarm status go to an incident commander or safety officer in real time. Honeywell's typical ranges:
Wireless costs battery life. The QRAE 3 datasheet shows runtime dropping from 14 to 10 hours (diffusion) and from 11 to 8 hours (pumped) with wireless on. Honeywell's MultiRAE runtimes are stated for non-wireless units only. On power, the MultiRAE has an edge: its battery packs swap without tools, and an adapter runs it on four AA alkaline cells for about six hours. Honeywell notes the vibration alarm is disabled on alkaline power.
Alarms match: a 95 dB buzzer at 30 cm, vibration, flashing red LEDs and on-screen alerts, plus a Man Down alarm with a pre-alarm and remote wireless notification. Honeywell's MultiRAE manual says Man Down is off by default and disabled when the monitor sits in a cradle or AutoRAE 2, so turn it on during setup. Both monitors show STEL, TWA, peak and minimum values and work with Honeywell SafetySuite device management.
The MultiRAE screen has twice the pixel count (128 x 160 vs 128 x 80) and three keys, which helps when you are scrolling a PID library or reading six values at once. The QRAE 3 runs on two buttons and its screen rotates 180°, so it reads right side up when clipped high on a harness or turnout coat.
Both log continuously at user-set intervals from 1 to 3,600 seconds. At one-minute intervals Honeywell rates the MultiRAE at six months of data for five sensors and the QRAE 3 at three months for four. That matters if you keep exposure records for industrial hygiene or need a record after an incident.
For ruggedness, the QRAE 3 diffusion model carries the better ingress rating (IP-67), while the pumped QRAE 3 and the MultiRAE are IP-65. Honeywell lists the MultiRAE as MIL-STD-810G and 461F compliant. Both are rated for Class I, Division 1, Groups A to D. The MultiRAE also carries a Class II, Division 1 (combustible dust) rating that the QRAE 3 datasheet does not list.
Honeywell lists confined-space entry, industrial safety, oil and gas, environmental, and fire and emergency response. That includes fireground detection of the "toxic twins," carbon monoxide and hydrogen cyanide. It fits teams that want a light four-gas monitor on every person.
Honeywell lists industrial hygiene, personal protection, leak detection, HazMat response and clandestine drug labs, in industries from aviation wing-tank entry to chemical, pharmaceutical and marine. See the MultiRAE listing.
The Lite is aimed at personal protection, leak detection and fire overhaul. The MultiRAE Pro pairs gamma with chemical sensing for hazmat, civil defense, homeland security and military teams.
Both monitors dock in the AutoRAE 2 for automatic bump testing and calibration (on the MultiRAE Lite, pumped version only). For the MultiRAE, Honeywell's manual calls for a bump test before each day's use. It also calls for calibration whenever a bump test fails, and at least every 180 days. The MultiRAE can also be set to enforce your own bump and calibration intervals. The QRAE 3 uses two-point zero and span calibration, manually or with AutoRAE 2. Honeywell's MultiRAE manual adds that only authorized personnel should replace the pump.
FarrWest is a Honeywell Authorized Service Provider for BW and RAE Systems gas detection. Our San Antonio Repair Depot handles warranty repair and calibration for both monitors, with calibration certificates tied to each serial number.
No. Honeywell's QRAE 3 datasheet lists a catalytic LEL sensor, an oxygen sensor and electrochemical sensors for H2S, CO, SO2 and HCN. For ppm VOC readings you need a MultiRAE with a PID: the MultiRAE reads 0 to 5,000 ppm, the Lite (pumped) 0 to 1,000 ppm, and the Pro adds a ppb PID.
Per Honeywell, the QRAE 3 weighs 12.9 oz as a diffusion unit and 14.5 oz pumped. The MultiRAE and MultiRAE Pro weigh 31 oz, and the MultiRAE Lite diffusion weighs 26.8 oz.
Yes. Honeywell lists fireground "toxic twins" detection as a QRAE 3 application. Its default sensor ranges are 0 to 500 ppm CO and 0 to 50 ppm HCN.
No. Honeywell sells both with or without the wireless modem. Live remote monitoring also needs a receiving system such as ProRAE Guardian or an EchoView Host, and may need extra equipment or software licenses.
Either works in its pumped version. The pumped QRAE 3 can draw a sample through up to 98 ft of tubing,. Choose a MultiRAE if the space may hold VOCs or toxics outside the QRAE 3's list.
Honeywell's MultiRAE manual calls for a bump test before each day's use. It calls for calibration whenever a bump test fails and at least every 180 days, depending on use and sensor exposure to poisons and contaminants.